![Hayward TriStar VS SP3200VSP Скачать руководство пользователя страница 40](http://html1.mh-extra.com/html/hayward/tristar-vs-sp3200vsp/tristar-vs-sp3200vsp_technical-manual_2110998040.webp)
Page 38
Code/Fault
Indications
Drive Error!
Comm failed
Indicates that there are communication problems inside the motor
drive, and that the motor drive may need to be replaced.
Drive Error!
Memory Failed
Indicates that the drive memory has been damaged or corrupted
and drive needs to be replaced.
Drive Error!
Unknown opcode
Indicates that the drive software has been corrupted, and that the
motor drive may need to be replaced.
Drive Error!
Startup failed
Indicates that the drive was not able to start the motor. Check
impeller, diffuser, shaft seal, and motor for issues.
Drive Error!
Unknown error
Indicates that the interface is receiving an error from the motor
drive that it does not understand.
The breaker is tripping.
Check input wiring and breaker. If still tripping breaker, replace
drive and motor.
Troubleshooting/Fault Codes