background image

 

 

 

USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

Page 4 of 36 

Super Pump VS Pump 

IS2603VSP  Rev-A 

Basic safety precautions should always be followed, including the following: Failure to follow instructions may result in 

injury. 

 This is the safety-alert symbol.  When you see this symbol on your pump or in this manual, look for one of the 

following signal words, and be alert to the potential for personal injury. 

 

WARNING

 

warns about hazards that 

could

 cause serious personal injury, death or major property damage 

and if ignored presents a potential hazard. 

 

CAUTION

 warns about hazards that 

will

 or 

can

 cause minor or moderate personal injury and/or property 

damage and if ignored presents a potential hazard.  It can also make consumers aware of actions that are 
unpredictable and unsafe.   

The 

NOTICE

 label indicates special instructions that are important but not related to hazards. 

1.

 

IMPORTANT SAFETY INSTRUCTIONS 

Before installing or servicing this electrical equipment, turn power supply OFF. 

 

 

 

WARNING

 

– 

READ AND FOLLOW ALL INSTRUCTIONS

 in this owner’s 

manual and on the equipment.  Failure to follow instructions can cause severe injury and/or death. 

 

WARNING

 – This product should be installed and serviced only by a qualified professional. 

 

CAUTION

 

– All electrical wiring MUST be in conformance with all applicable local codes, regulations, and 

the National Electric Code (NEC). 

USE OF NON-HAYWARD REPLACEMENT PARTS VOIDS WARRANTY. 

ATTENTION INSTALLER - THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION, 
OPERATION, AND SAFE USE OF THIS VARIABLE SPEED PUMP THAT MUST BE FURNISHED TO THE END USER OF THIS 
PRODUCT.  FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS COULD RESULT IN SERIOUS INJURY. 

 

 

 

WARNING

 – To reduce risk of injury, do not permit children to use or climb on this product.  Closely 

supervise children at all times.  Components such as the filtration system, pumps, and heaters must be positioned 
to prevent children from using them as a means of access to the pool. 

 

CAUTION

 – This pump is intended for use on permanently installed swimming pools and may also be used 

with hot tubs and spas if so marked.  Do NOT use with storable pools.  A permanently installed pool is constructed in 
or on the ground or in a building such that it cannot be readily disassembled for storage.  A storable pool is 
constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity.  
Though this product is designed for outdoor use, it is strongly advised to protect the electrical components from the 
weather.  Select a well-drained area, one that will not flood when it rains.  It requires free circulation of air for 
cooling.  Do not install in a damp or non-ventilated location.  If installed within an outer enclosure or beneath the 
skirt of a hot tub or spa, adequate ventilation and free circulation of air must be provided to prevent overheating of 
the motor. 

 

 

Содержание Super Pump VS SP2603VSP

Страница 1: ...ermanent magnet motor Super Pump VS is easily installed either as a programmable stand alone pump or with a Hayward or third party controller and features an easy to use digital control interface that...

Страница 2: ...Procedure 14 5 Wiring Diagrams 15 5 1 Input Power Wiring Required 15 5 2 Wall Mounted Digital Control Interface Wiring Optional 15 5 3 External Relay Speed Control Wiring Optional for remote selection...

Страница 3: ...3 Removing the Ceramic Seat 27 9 4 Seal Installation 27 9 5 Replacing the Impeller and Diffuser 27 9 6 Replacing the Motor Assembly 28 10 Replacement Parts 28 10 1 Parts Diagram 28 10 2 Parts Listing...

Страница 4: ...l Electric Code NEC USE OF NON HAYWARD REPLACEMENT PARTS VOIDS WARRANTY ATTENTION INSTALLER THIS MANUAL CONTAINS IMPORTANT INFORMATION ABOUT THE INSTALLATION OPERATION AND SAFE USE OF THIS VARIABLE SP...

Страница 5: ...ARNING Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death To reduce the risk of electric shock see installation instructions and consult a...

Страница 6: ...be in off position and filter manual air relief valve must be in open position Before starting pump all system valves must be set in a position to allow system water to return back to the pool Do not...

Страница 7: ...ced hydraulic design Fully programmable with a self contained 24 hour clock and up to 8 custom speed and timer functions For enhanced pool management can be controlled by Hayward or third party pool a...

Страница 8: ...ce every 24 hours Check with local requirements for the minimum turnover rate Running the pump at a lower speed may require running the pump for a longer period of time in order to meet the turnover r...

Страница 9: ...ARNING Hazardous Pressure Pumps filters and other equipment components of a swimming pool filtration system operate under pressure Incorrectly installed and or improperly tested filtration equipment a...

Страница 10: ...required by code Connect ground terminal to electrical service ground 3 Bond pump to pool structure Bonding will connect all metal parts within and around the pool with a continuous wire Bonding redu...

Страница 11: ...e section 5 3 for more information regarding connecting Super Pump VS and third party non software compatible Hayward controls 3 Super Pump VS can communicate with and be controlled by Hayward pool an...

Страница 12: ...he W S485 terminal tion The cabl t provided on ed for the cabl Figure 4 12 4 wall mount pla plate taking re DR9 on the mo ure 4 12 3 esume norma interface wal moving the Dig GENUINE RE Pump VS Pu part...

Страница 13: ...12 2 Re USE ONLY H emoving the I F HAYWARD G Super P nterface Mou igure 4 12 3 A GENUINE RE Pump VS Pu unting Plate to Adding the Bl PLACEMENT ump o access the D lank Cover T PARTS Drive wiring co IS...

Страница 14: ...elay contacts as shown in the External Relay Speed Control Wiring diagram See section 5 3 6 If the installation will use the remote stop feature of the drive connect the digital input terminals to the...

Страница 15: ...ce Wiring Optional Figure 5 2 1 Connection wire must be rated for a minimum of 300V and may be up to 500 feet in length Use removable 4 position terminal block connectors for wiring connection to inte...

Страница 16: ...ing relay contacts to select the speeds set in the Timer Menu see section 6 7 In addition to this section you may also consult the applicable pool control installation manual for electrical connection...

Страница 17: ...otor drive PCB taking care to note the wire colors and corresponding numbers next to the connectors Terminal block must be installed with screws facing up to ensure proper connection When communicatin...

Страница 18: ...d the SW200 DIP switch 1 must be ON 6 Startup Operation 6 1 Prior to Start Up If it is necessary to perform a water pressure test prior to initial use to ensure plumbing system is functioning properly...

Страница 19: ...or ATTENTION Do NOT add chemicals to pool spa system directly in front of pump suction Adding undiluted chemicals may damage pump and voids warranty ATTENTION Before removing strainer cover 1 STOP PUM...

Страница 20: ...hrough the setup menus when pressed The and arrow buttons are used to move between displays and to select parameters to edit and the and arrow buttons are used to change parameters 3 Status LEDs The C...

Страница 21: ...uals 1 through 4 c Speed X Speed where X equals 1 through 4 4 Diagnostics Menu see section 6 9 to view product diagnostic information a Display Firmware Revision b Drive Serial Number c Motor Drive Fi...

Страница 22: ...30 second increments 10 Select Stand Alone or Relay Control Move to next menu item Note See section 5 3 for more detail 11 Enable or Disable Low Temp Operation Move to next menu item 12 Set temperatu...

Страница 23: ...s are to run 7 days per week 5 days per week Monday thru Friday or on a single day Monday thru Sunday Each timer is set up in this same manner When the pump is powered and the timers are set up the Ti...

Страница 24: ...d without entering the Speeds Menu using the and arrow buttons to change the speed and then pressing the button to save the new speed setting 6 9 Diagnostic Menu Buttons Screen Used Comments 1 Use to...

Страница 25: ...operation the above message will be displayed The pump will stop within several seconds and will remain stopped until Stop Resume is pressed a second time at which point the pump will resume normal o...

Страница 26: ...volume blower when air purging the pump filter or piping ATTENTION Allowing the pump to freeze with water in it will void the warranty ATTENTION Use ONLY propylene glycol as antifreeze in your pool sp...

Страница 27: ...expose the impeller 9 2 Removing the Impeller 3 To prevent the motor shaft from turning secure using a 5 16 hex wrench on the motor shaft through the fan shroud on the back of the pump 4 Remove the im...

Страница 28: ...isturb the diffuser gasket 14 Fasten assembly to pump strainer housing using the four 4 3 8 x 2 bolts Be sure housing gasket is in place and lubricated Replace if damaged Tighten bolts alternately and...

Страница 29: ...X1600F5 Motor Mounting Plate 1 14 SPX0125z44 Motor Cap Screws Set of 4 1 15 SPX1600Z4 Housing Cap Screw 4 16 SPX2600G1 Mounting Foot Includes Screws 1 17 SPX1600Z52 Mounting Foot Screws Set of 2 1 18...

Страница 30: ...asket loaded with debris Remove the strainer housing cover or the skimmer cover Clean the basket and refill the strainer housing with water Tighten the cover 5 Suction side clogged Contact a qualified...

Страница 31: ...to the equipment pad 3 Foreign matter in the pump housing Loose stones debris hitting the impeller could be the cause Clean the pump housing 4 Motor bearings noisy from normal wear rust overheating o...

Страница 32: ...ical Service for additional assistance Check System Processor failed Indicates that there is a problem with the processor in the motor drive and that the motor drive may need to be replaced Contact Ha...

Страница 33: ...IS2603VSP Rev A DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING CLEAN FILTER _______________________ PUMP MODEL __________________ 12 Warranty 13 Product Registration Retain t...

Страница 34: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 34 of 36 Super Pump VS Pump IS2603VSP Rev A THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 35: ...USE ONLY HAYWARD GENUINE REPLACEMENT PARTS Page 35 of 36 Super Pump VS Pump IS2603VSP Rev A THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 36: ...__________________________ Type of Pool Concrete Gunite Vinyl Fiberglass Other_____________________________ New Installation Replacement Installation for In Ground Spa FCC Compliance Statement This de...

Отзывы: