USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Page 24 of 36
Super Pump VS Pump
IS2603VSP Rev-A
6.8.
Preset Speed Setup Menu
Buttons
Screen Used
Comments
1.
< >
Use > to enter Speeds Menu
2.
+ -
Use to rename displayed speed
< >
Move to next menu item
3.
+ -
Use to set duration of speed
< >
Move to next menu item
Note:
Each time a preset speed is selected, it will run for the programmed duration. Multiple presses of the speed
button will add more time according to the set duration up to a maximum of 12 hours.
4.
+ -
Use to set motor speed for displayed speed
< >
Move to next menu item
Note:
Preset Speed settings can also be quickly updated without entering the Speeds Menu using the + and - arrow
buttons to change the speed and then pressing the > button to save the new speed setting.
6.9.
Diagnostic Menu
Buttons
Screen Used
Comments
1.
< >
Use > to enter Diagnostic Menu
and toggle between displays
2.
Displays firmware version of the display PCB.
3.
Displays motor drive serial number.
4.
Displays firmware revisions of the motor drive and drive
board and display board interface PCB’s.
5.
Displays status of internal DC bus voltage.
6.
Real-time display of motor input current.
Speeds Menu
Press > to enter
Speed 1 Name
Speed 1
Speed 1 Duration
0:30 hours
Speed 1 Speed
1725 (600-3450rpm)
Diagnostic Menu
Press > to enter
Display Revision
1.03
Drive Serial Number
DET-3581200032
DC Bus Voltage
Within Range
Motor Current
1.1A (8.5A Max)
Comm Rev: 2.15
Drv Rev: 2.00.oz