Hayward Aqua Plus 16v PL-PLUS-16V Скачать руководство пользователя страница 6

ºC       ºF       

 

Ti

Calcuim

Hardness

Ci

Total

Alkalinity

Ai

53

60

66

76

84

94

103

12

16

19

24

29

34

39

.3

.4

.5

.6

.7

.8

.9

How to use: 

Measure pool pH, temperature, calcium hardness,

and total alkalinity.  Use the chart above to determine Ti, Ci,and

Ai from your measurements.  Insert values of pH, Ti, Ci and Ai
into the above equation.  If Si equals .2 or more, scaling and 

staining may occur.  If Si equals -.2 or less corrosion or irritation

may occur. 

Si = pH + Ti + Ci + Ai - 12.1

-.2

0

.2

CORROSIVE

SCALING

75

75

100

100

125

125

150

150

200

200

250

250

300

300

400

400

600

600

800

800

1.5

1.9

1.6

2.0

1.7

2.1

1.8

2.2

1.9

2.3

2.0

2.4

2.1

2.5

2.2

2.6

2.4

2.8

2.5

2.9

OK

3

1.  Preparing Pool/Spa Water

General Water Chemistry

Salt is required only if you are using the chlorinator features on the Aqua Plus 16v Control. If you are NOT using

the chlorinator, it is recommended that you follow all of the other chemistry recommendations besides salt. Refer to

the description of the Aqua Plus 16v configuration menu for information on enabling/disabling the chlorinator (see

page 24).

Water Chemistry

The table below summarizes the levels that are recommended by the Association of Pool and Spa Professionals

(APSP).  The only special requirements for the Aqua Plus 16v are the salt level and stabilizer.

Saturation index

The saturation index (Si) relates to the calcium and alkalinity in the water and is an indicator of the pool water

“balance”.  Your water is properly balanced if the Si is 0 ±0.2.  If the Si is below -0.2, the water is corrosive and

plaster pool walls will be dissolved into the water.  If the Si is above +0.2, scaling and staining will occur.  Use the
chart below to determine the saturation index.

The pool’s chemistry must be balanced BEFORE activating the Aqua Plus 16v’s optional chlorinator function.

NOTE:  If the pool does not have new water, add metal remover and non-copper based algaecide to the pool, per

manufacturer’s instructions.  This ensures a quick, troublefree transfer to the Aqua Plus 16v system.

40

Reset ColorLogic to

Default    Press +

Are you sure?

+ to proceed

ColorLogic. reset

Confirmed

Initiate reset of ColorLogic configuration parameters

Reset all configuration parameters

Move to previous/next configuration menu  (config. not reset)

Move to previous/next menu (config. not reset)

Move to previous/next configuration menu 

if ColorLogic Network Module is detected

Use this function to erase all ColorLogic configuration settings and reset back to the factory default
values.   This function is NOT reversible--be careful.

Reset Config. to

Default    Press +

Are you sure?

+ to proceed

Config. reset

Confirmed

Initiate reset of all configuration parameters

Reset all configuration parameters

Move to previous/next configuration menu  (config. not reset)

Move to previous/next menu (config. not reset)

Move to previous/next configuration menu 

Use this function to erase all previous system configuration settings and reset all configuration
parameters back to the factory default values.   This function is NOT reversible--be careful.

Maintenance Menu 

(only displays if Sensing System is enabled)

The Maintenance Menu will be displayed only if the optional AQL-CHEM is used and the Sensing System is

enabled in the Chemistry Config. Wizard. This menu is used to perform functions relating to the AQL-CHEM ORP

and pH sensing kit.

pH Calibration

Wizard, + to enter

Push to access pH Calibration Wizard
Move to previous/next menu item

Use this Wizard to calibrate the AQL-CHEM’s pH probe.  This requires a manual pH test of the pool
water using a dependable red phenol test kit.

Clean Probe Wizard

+ to enter

Push to access Clean Probe Wizard
Move to previous/next menu item

Use this Wizard to clean the AQL-CHEM’s ORP and pH probes. The probes must be clean and free
from oil, chemical deposits and contamination to function properly.  Slow response, increased need to
calibrate, and inconsistent readings are indications that the probes need to be cleaned.

Содержание Aqua Plus 16v PL-PLUS-16V

Страница 1: ...ach wireless remote wireless channel maintenance menu pH calibration wizard clean probe wizard timers menu pool filter 1 or hi speed 1 pool filter 2 or lo speed 1 pool filter 3 or hi speed 2 pool filt...

Страница 2: ...ytotheoriginalowner Proofofpurchaseisrequiredforwarrantyservice Ifwrittenproofofpurchaseisnotprovided themanufacturing date code will be the sole determinant of the date of installation of the product...

Страница 3: ...tion 7 Optional ValveActuators 7 3 Plumbing Standard Pool Spa Configuration 8 Dual Equipment Pool Spa Separate Heaters 9 Dual Equipment Pool Spa Shared Heaters 10 Turbo Cell 11 Flow Switch 11 4 Electr...

Страница 4: ...product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios decking a qualified stone installation specialist should be con...

Страница 5: ...olar thermostat settings Chlorinatorsettings DayandTime Timers Menu Timeclockand orCountdowntimersettings Heater Checkout FollowtheseinstructionstoverifythattheAquaPlus16visproperlycontrollingtheheate...

Страница 6: ...the pool per manufacturer s instructions Thisensuresaquick troublefreetransfertotheAquaPlus16vsystem 40 Reset ColorLogic to Default Press Are you sure to proceed ColorLogic reset Confirmed Initiate re...

Страница 7: ...peciallyimportantforretrofitinstallationtoolderpoolswhereallofthe chlorineaddedtothepoolovertimeisendingupassalt Ifthelevelislow determinethenumberofgallonsinthe pool and add salt according to the cha...

Страница 8: ...4 3 0 1 4 3 5 1 6 2 5 1 6 4 5 2 0 5 5 2 5 8 0 3 6 6 5 2 9 9 0 4 1 7 0 3 2 9 5 4 3 7 5 3 4 10 0 4 5 2 0 91 1 3 91 2 0 91 2 8 1 3 2 3 1 1 1 7 1 1 2 7 1 2 3 3 1 5 3 7 1 7 5 3 2 4 4 3 2 0 4 7 2 1 6 3 2 8...

Страница 9: ...r Valve3 Name Waterfall Push to access Valve3 options Rotates between Manual On Off default Countdown Timer Timeclock Solar In floor Cleaner Group and Super Chlorinate Move to previous next configurat...

Страница 10: ...theAQL2 BASE RFforallAQL2wirelessremotecontrols Toinstallthebasestation removetheknockout on the upper left side of theAqua Plus 16v main control unit insert the base station and then tighten the nut...

Страница 11: ...sing kit Aux1 Relay This feature allows the user to select either Standard default Dimmer ColorLogic or VSP type relay for the Aux1 output The optionalAQL DIM dimmer kit must be installed if Dimmer is...

Страница 12: ...ff countdown timer and timeclock functions Move to next menu item Rotates between Manual On Off default Countdown Timer Low Speed Filter Timeclock Solar Low Speed Spa Filter Group Super Chlorinate and...

Страница 13: ...et water flowing when the pool spa suction return valves are in any position other than pool only or for the first 3 minutes after solar turns on allows air in the solar panels to be purged Interlock...

Страница 14: ...e Aux relays If pool lights are wired to the lights relay some options including Solar function Low Speed of a 2 Speed Filter Pump Lights Interlock and Lights Freeze Protection are not applicable and...

Страница 15: ...e between Open and Closed default Move to next menu item or previous next configuration menu External Input The external input device can either be normally open or normally closed In this menu select...

Страница 16: ...ove to next menu item Move to next menu item if Solar is enabled if Solar is enabled Allow Low Speed Disabled Toggle between Enabled and Disabled default Move to next menu item or previous next config...

Страница 17: ...ext configuration menu if Heater1 is enabled if Heater1 is enabled if Heater1 is enabled display for Heater2 if Heater2 is enabled Heater1 Name Gas Heater Rotates between all available names Move to n...

Страница 18: ...Lowest Speed 10 Highest Speed 100 Rotates between 1 speed default 2 speed and variable speed options Toggle between Enabled default and Disabled Freeze Protection Toggle between high speed default and...

Страница 19: ...irst 3 minutes of operation anytime the pump has been off for more than 30 seconds Set highest speed from 20 to 100 default Flow Monitor This feature will help protect the filter pump from damage due...

Страница 20: ...ver the Pool Spa valves are turning The pump will NOT shut off when the heater has Cooldown enabled and is either on or in the Heater Cooldown mode Filter Config to view change Filter Name Pool Filter...

Страница 21: ...actuators should be connected to the Pro Logic Pressing the POOL SPAbutton on the display keypad will allow the homeowner to alternate between pool and spa operation If Pool and Spa Dual is selected...

Страница 22: ...ically locks after 2 minutes of no buttons being pressed to prevent unauthorized people from changing the control logic inadvertently and possibly damaging the pool equipment or causing a call back to...

Страница 23: ...while the Group is running will make the Group release the alternate setpoint control and revert back to the normal heater setting Any changes that are made at that point will affect the normal heater...

Страница 24: ...d dim the patio lights turn on the music etc all at the same time This convenient feature is offered on allAux buttons bothValve buttons and the Lights button TheAqua Plus 16v can be programmed to con...

Отзывы: