3. Plumbing

“Standard” Pool/Spa system configuration

These systems use a single filter pump and filter.  Pool or spa operation is controlled by two 3-way valves (suction

and return).  Refer to the diagram below.

Some important notes regarding the Aqua Plus 16v control of Standard Pool/Spa systems:

In Pool/Spa Config., select:      

Pool/Spa Setup

Pool and Spa-Std

1. The Aqua Plus 16v can be programmed to accommodate spa spillover, if desired.
2. Up to two conventional heaters (gas or heat pump) plus solar can be used to heat both the pool and the

spa.

3. If the chlorinator cell is plumbed prior to the pool/spa return valve, then both the pool and the spa can be

chlorinated.

4. The water sensor should be installed prior to any heater or solar and will display either the pool or the spa

temperature, depending on the current operation of the pool.  The temperature will only be displayed when
the filter pump is running.

5. If any water feature or pressure side cleaner boost pumps are used, be sure to enable the “interlock”

feature (see “Configuration Menu” for details) to ensure that the pumps operate only when the filter pump
is on and the system is in the “pool only” operating mode.

6. The plumbing diagram above is intended to be used as a general guideline and is not a complete plumbing

schematic for the pool.

7. The air sensor must be installed if the freeze protection feature is enabled for the filter, valves or aux

outputs.

8

35

Timeclock

 – the aux relay will turn-on and turn-off at the times set for the aux timeclock in the Timers

Menu (see Operations Manual).  The AUX button can also be used to turn the output on and off.

Solar

 – the aux relay operates a solar booster pump which will turn on when the filter pump is running

and solar heat is available and the water is less than the desired temperature setting.  It is important to
note that “Solar” must be enabled in the “Solar Config.” menu for proper operation to occur.

Low Speed of a 2-Speed Spa Filter Pump

 – the Pro Logic will turn on the aux relay whenever the low

speed operation of the Dual Equipment Spa filter pump is required.  “Pool and Spa-Dual” (located in
Pool/Spa Setup menu) and “2-Speed” (located in Spa Filter Config. menu) must be selected for proper
operation.

Group 

 – the aux relay operates when the Group function is initiated and shuts off when the Group

function is terminated.  See Aux1 Group section for operation information for the Group function.

Super Chlorinate 

 – The Super Chlorinate function can be assigned to any Aux, Lights or Valve

button.  This allows the user to simply hit a button to start a Super Chlorinate cycle, rather than using
the Settings Menu.  Note that only one button can me assigned to this function.

pH Dispense 

 – When Chemistry Sensing is enabled and pH Reduction Control is NOT disabled, the

Pro Logic will turn on the Aux relay when there is a need to energize the pH dispensing device. The pH
Dispense function can be assigned to any Aux or the Lights output. Once programmed for pH Dispense,
the Aux button will have no function.  Requires the use of the AQL-CHEM sensing kit.

Aux1 Relay

This feature allows the user to select either “Standard” (default), “Dimmer”, “ColorLogic” or “VSP”
type relay for the Aux1 output.  The optional AQL-DIM dimmer kit must be installed if “Dimmer” is
desired.  The AQL-COLOR-MODHV ColorLogic Network Module must be installed if “ColorLogic” is
desired.

When “Dimmer” is selected, and the Aux1 output is manually turned on, the “+” and “-” buttons
adjust the level from 20% to 100% (default).  The level is saved for the next time the aux1 output is
turned from off to on.

If “ColorLogic” is selected (Network Module must be detected at startup for this option to appear),
additional menus will prompt you for configuration information.  Refer to the AQL-COLOR-MODHV
manual for details on how to configure an Aux output for use with Generation 3 or later ColorLogic
lights.

If “VSP” is selected, the Aux relay is used to supply power to a Hayward Variable Speed Pump (VSP).
The relay will be on when the Aux output is on and off when the output is off.  On, off and speed are
controlled by commands sent to the VSP.  Note: Up to 6 Lights/Aux outputs can be configured as VSP
relays.

Aux1 Interlock

If “Enabled”, this feature will override the function (Manual On/Off, Countdown Timer, Timeclock),
selected above and turn the aux1 off when:  filter pump is off, first 3 minutes of filter pump operation
(allows the pump to prime and get water flowing), when the pool/spa suction return valves are in any
position other than “pool only”, or for the first 3 minutes after solar turns on (allows air in the solar
panels to be purged).  Interlock is not available for solar, low speed filter pump, dimmer, group, super
chlorinate or pH dispense functions.

Aux1 Group

The Aux1 Group function allows the user to perform multiple tasks with a single push of the “Aux1”
button. When setting up a Group function, refer to page 22 for specific programming information.
There are two Group menus; the first menu determines how the group command will be initiated
(Manual On/Off, Countdown Timer, or Timeclock) and the second menu selects the desired functions
and their respective control parameters.

When activating Group functions, be aware that the most recent Group function that is initiated will
override any previous Group function.

FILTER

SOLAR BOOST

PUMP

SOLAR

VALVE

HEATER

HEAT

PUMP

HEATER

BYPASS

VALVE

(manual)

CELL

FLOW

SWITCH

CHECK

VALVE

POOL SWEEP

BOOST PUMP

WATER

FEATURE 

PUMP

POOL/SPA

RETURN 

VALVE

WATER

FEATURE

VALVE

SPA

SPA JET

PUMP

SPA

BLOWER

POOL/SPA SUCTION

VALVE

CHECK VALVE

POOL VACUUM

VALVE

MANUAL

VALVE

MANUAL

VALVE

MANUAL

VALVE

ENERGY

FILTER

TWO-WAY

VALVE

SKIM

POP-UP

SPILLOVER

POP-UP

OVERFLOW

POP-UP

RETURN

JET

IN-FLOOR

CLEANER

VALVE

WATER

FEATURE

PUMP

WATER

FEATURE

POP-UP

MAIN

DRAIN

ENERGY

SAVER

PRESSURE

CLEANER

NON-BOOST

PRESSURE

CLEANER

PRESSURE

CLEANER

SUCTION

CLEANER

SOLAR

TEMPERATURE

SENSOR

POOL

FILTER

PUMP

High Voltage Relays

Valve Outputs

Filter Pump

Lights
Aux 1

Aux 2

Pool/Spa Suction

Pool/Spa Return

Valve 3

Valve 4

TRANSFORMER

HIGH VOLTAGE

LIGHTS

LOW VOLTAGE

LIGHTS

FIBER OPTIC

LIGHT SOURCE

COLOR WHEEL

ISOLATED

WATER

FEATURE

PUMP

POOL/SPA

TEMPERATURE

SENSOR

CHECK

VALVE

(prevents draining

of raised spas)

CHECK

VALVE

(prevents draining

of raised spas)

Содержание Aqua Plus 16v PL-PLUS-16V

Страница 1: ...ach wireless remote wireless channel maintenance menu pH calibration wizard clean probe wizard timers menu pool filter 1 or hi speed 1 pool filter 2 or lo speed 1 pool filter 3 or hi speed 2 pool filt...

Страница 2: ...ytotheoriginalowner Proofofpurchaseisrequiredforwarrantyservice Ifwrittenproofofpurchaseisnotprovided themanufacturing date code will be the sole determinant of the date of installation of the product...

Страница 3: ...tion 7 Optional ValveActuators 7 3 Plumbing Standard Pool Spa Configuration 8 Dual Equipment Pool Spa Separate Heaters 9 Dual Equipment Pool Spa Shared Heaters 10 Turbo Cell 11 Flow Switch 11 4 Electr...

Страница 4: ...product as part of a saline water purification system in a pool or spa using natural stone for coping or for immediately adjacent patios decking a qualified stone installation specialist should be con...

Страница 5: ...olar thermostat settings Chlorinatorsettings DayandTime Timers Menu Timeclockand orCountdowntimersettings Heater Checkout FollowtheseinstructionstoverifythattheAquaPlus16visproperlycontrollingtheheate...

Страница 6: ...the pool per manufacturer s instructions Thisensuresaquick troublefreetransfertotheAquaPlus16vsystem 40 Reset ColorLogic to Default Press Are you sure to proceed ColorLogic reset Confirmed Initiate re...

Страница 7: ...peciallyimportantforretrofitinstallationtoolderpoolswhereallofthe chlorineaddedtothepoolovertimeisendingupassalt Ifthelevelislow determinethenumberofgallonsinthe pool and add salt according to the cha...

Страница 8: ...4 3 0 1 4 3 5 1 6 2 5 1 6 4 5 2 0 5 5 2 5 8 0 3 6 6 5 2 9 9 0 4 1 7 0 3 2 9 5 4 3 7 5 3 4 10 0 4 5 2 0 91 1 3 91 2 0 91 2 8 1 3 2 3 1 1 1 7 1 1 2 7 1 2 3 3 1 5 3 7 1 7 5 3 2 4 4 3 2 0 4 7 2 1 6 3 2 8...

Страница 9: ...r Valve3 Name Waterfall Push to access Valve3 options Rotates between Manual On Off default Countdown Timer Timeclock Solar In floor Cleaner Group and Super Chlorinate Move to previous next configurat...

Страница 10: ...theAQL2 BASE RFforallAQL2wirelessremotecontrols Toinstallthebasestation removetheknockout on the upper left side of theAqua Plus 16v main control unit insert the base station and then tighten the nut...

Страница 11: ...sing kit Aux1 Relay This feature allows the user to select either Standard default Dimmer ColorLogic or VSP type relay for the Aux1 output The optionalAQL DIM dimmer kit must be installed if Dimmer is...

Страница 12: ...ff countdown timer and timeclock functions Move to next menu item Rotates between Manual On Off default Countdown Timer Low Speed Filter Timeclock Solar Low Speed Spa Filter Group Super Chlorinate and...

Страница 13: ...et water flowing when the pool spa suction return valves are in any position other than pool only or for the first 3 minutes after solar turns on allows air in the solar panels to be purged Interlock...

Страница 14: ...e Aux relays If pool lights are wired to the lights relay some options including Solar function Low Speed of a 2 Speed Filter Pump Lights Interlock and Lights Freeze Protection are not applicable and...

Страница 15: ...e between Open and Closed default Move to next menu item or previous next configuration menu External Input The external input device can either be normally open or normally closed In this menu select...

Страница 16: ...ove to next menu item Move to next menu item if Solar is enabled if Solar is enabled Allow Low Speed Disabled Toggle between Enabled and Disabled default Move to next menu item or previous next config...

Страница 17: ...ext configuration menu if Heater1 is enabled if Heater1 is enabled if Heater1 is enabled display for Heater2 if Heater2 is enabled Heater1 Name Gas Heater Rotates between all available names Move to n...

Страница 18: ...Lowest Speed 10 Highest Speed 100 Rotates between 1 speed default 2 speed and variable speed options Toggle between Enabled default and Disabled Freeze Protection Toggle between high speed default and...

Страница 19: ...irst 3 minutes of operation anytime the pump has been off for more than 30 seconds Set highest speed from 20 to 100 default Flow Monitor This feature will help protect the filter pump from damage due...

Страница 20: ...ver the Pool Spa valves are turning The pump will NOT shut off when the heater has Cooldown enabled and is either on or in the Heater Cooldown mode Filter Config to view change Filter Name Pool Filter...

Страница 21: ...actuators should be connected to the Pro Logic Pressing the POOL SPAbutton on the display keypad will allow the homeowner to alternate between pool and spa operation If Pool and Spa Dual is selected...

Страница 22: ...ically locks after 2 minutes of no buttons being pressed to prevent unauthorized people from changing the control logic inadvertently and possibly damaging the pool equipment or causing a call back to...

Страница 23: ...while the Group is running will make the Group release the alternate setpoint control and revert back to the normal heater setting Any changes that are made at that point will affect the normal heater...

Страница 24: ...d dim the patio lights turn on the music etc all at the same time This convenient feature is offered on allAux buttons bothValve buttons and the Lights button TheAqua Plus 16v can be programmed to con...

Отзывы: