3"
76mm
4 5/8"
117mm
6"
152mm
8 3/4"
222mm
BRACKET
HEIGHT
(SEE TABLE
ABOVE)
2 5/8"±1/4"
67mm±6
HAWS COOLER
MOUNTING BRACKET
5
FLOOR LINE
NOTE LOCATING
NOTCH FOR
DRAIN STUB-OUT
CENTERLINE
PERMISSIBLE LOCATIONS FOR DRAIN STUB-OUT
2 7/8"
73mm
6 5/16"
161mm
2 3/8"
61mm
MAX
DRAIN STUB-OUT/P-TRAP DETAIL
(VIEWED FROM TOP)
DRAIN
STUB-OUT
(NOT SUPPLIED)
1-1/4" P-TRAP
(NOT SUPPLIED)
WALL
FACE
6
8 3/4"
222mm
FROM HANGER
BRACKET HOLES
3" [76mm]
FROM HANGER
BRACKET HOLES
PAGE 15 OF 17
RETROFIT INSTALLATION
DETAILS
NOTES:
3 THE 12XX COOLER SERIES IS ABLE TO RETROFIT IN PLACE OF A NUMBER OF COMPETITOR MODELS. SEE
RETROFIT TABLE ABOVE FOR PARTIAL LIST OF COOLERS ABLE TO BE REPLACED BY THIS ONE.
THE FOLLOWING DISCLAIMERS APPLY:
THE 12XX COOLER CENTERLINE MAY NOT MATCH THE OLD COOLER'S CENTERLINE, SINCE THE 12XX
•
COOLER DRAIN MUST BE 2 5/8" OFF OF CENTER. THIS MAY AFFECT ADA COMPLIANCE.
THERE MUST BE WALL BLOCKING OR OTHER STRUCTURAL MATERIAL BEHIND HAWS MOUNTING HOLES.
•
VERIFY THAT DRAIN, ELECTRIC, & WATER SERVICES ARE LOCATED WITHIN BOUNDARIES SPECIFIED ON
•
THIS SHEET AND THE NEXT. SOME RETROFITS MAY REQUIRE THE ELECTRIC OUTLET TO BE MOVED.
4 THE P-TRAP IS NOT SUPPLIED. THE VERTICAL DIMENSIONS GIVEN ARE BASED UPON INSTALLATION USING
OF A KEENEY 200W P-TRAP, AND SHOULD THEREFORE BE REGARDED AS REFERENCE-ONLY.
5 THE CENTERLINE OF THE DRAIN STUB-OUT MUST BE BETWEEN 3" [76mm] & 4-5/8" [118mm]
OR
BETWEEN 6"
[152mm] & 8-3/4" [229mm] BELOW THE LOWERMOST EWC MOUNTING BRACKET HOLES IN ORDER FOR THE
P-TRAP TO AFFIX PROPERLY TO THE DRAIN TAILPIECE.
- DEPENDING ON STUB-OUT HEIGHT, SOME TRIMMING OF THE TAILPIECE WILL BE REQUIRED.
6 WHATEVER P-TRAP AND STUB-OUT PLUMBING ARE USED, CARE SHOULD BE TAKEN TO ENSURE THAT THE
P-TRAP CAN SEAL TO THE STUB-OUT PROPERLY AND STILL ALIGN TO THE DRAIN TAILPIECE (LOCATED AT
THE GIVEN DIMENSIONS).
HIGHEST & LOWEST
P-TRAP HEIGHTS
5
PAGE 15 OF 17
BRACKET HEIGHT
ADULT ADA
MAX
ADULT ADA
MIN
CHILD ADA
32 3/8"
28 3/8"
25 3/8"
3
RETROFIT TABLE
MANUFACTURER
MODEL
HAWS
ALL MODELS STARTING WITH
HWUACP
ELKAY/HALSEY
TAYLOR
- ALL MODELS STARTING WITH EB,
EI, EMA, EN, EZ, HAC HVR, LI, LMA,
LZ, TB, & TI
- SINGLE COOLER MODELS
STARTING WITH VRC & LVR
OASIS
ALL VERSACOOLER II MODELS
SUNROC
ALL MODELS STARTING WITH ADA
MURDOCK
A171, A171.8, & A172.8UBL MODELS
NOTE: THE WATER STOP VALVE
MUST BE RELOCATED TO RETROFIT
A FILTERED 12XX COOLER
© 2021 Haws Corporation - All Rights Reserved. HAWS® and other trademarks used in these materials are the exclusive property of Haws Corporation.
THIS DOCUMENT IS TRUE AND CORRECT AT TIME OF PUBLICATION. CONTINUED PRODUCT
IMPROVEMENTS MAKE SPECIFICATIONS AND MEASUREMENTS SUBJECT TO CHANGE WITHOUT NOTICE.
APPROVED:
DRAWN:
PART NUMBER
SCALE:
REVISION
JL
07/25/18
0A.0
1:8
DRAWING TYPE:
SIZE: A
5647
BY:
INSTALLATION
DATE:
DATE:
REV. ECN:
5647
CHK'D.:
MODEL(S)
1455 KLEPPE LANE
SPARKS, NEVADA 89431
(775) 359-4712 FAX (775) 359-7424
E-MAIL: [email protected]
WEBSITE: WWW.HAWSCO.COM
DHP
ECN:
SHEET 3 OF 5
0510001159.D
12XX ELECTRIC WATER COOLERS