01/21 1210 Series Bottle Fillers
Page 6 of 17
E. MAINTENANCE
E.1. CLEANING
•
Metal parts can be cleaned with either of the following:
o
A clean towel, dampened by warm water with or without a small amount of mild hand dishwashing detergent.
o
Stainless steel cleaning wipes. Buff off excess with a clean cloth or paper towel. Do not allow the cleaning
fluid to touch the plastic parts or the bottle filler.
•
Plastic parts (including bottle filler):
o
A clean towel, dampened by warm water with or without a small amount of mild hand dishwashing detergent.
•
Condenser: If dust builds up on the condenser, it can negatively impact the
bottle filler’s performance and longevity.
Clean the condenser using a shop vacuum or an air blower gun. Take care not to damage the fins during the cleaning
process.
E.2. Y-STRAINER CLEANOUT (MODELS WITHOUT A FILTER)
1.
Remove the (4) screws holding the skirt to the bottom of the frame. Then
remove the skirt by sliding the skirt away from the lower unit.
2.
Turn the supply valve to the off position.
3.
Remove the cap from the strainer using two adjustable or open-ended
wrenches.
a.
NOTE: Some water will likely drip out of the y-strainer as you open
it.
4.
Clean the strainer screen using clean water.
5.
Re-assemble the cap to the strainer.
6.
Turn the supply valve to the on position and check for leaks.
7.
Reinstall the skirt.
E.3. FILTER REPLACEMENT (MODELS WITH A FILTER)
Caution: Take care not to damage the circuit board located near the filter head
during the following steps.
1.
Remove the (4) screws holding the skirt to the bottom of the frame. Then
remove the skirt by sliding the skirt away from the lower unit.
2.
Place a towel or bucket below the lower unit to collect the small amount of
water that may drip from the filter head or filter during the next steps.
3.
Optional: Turn the water supply valve to the off position, and bleed pressure
from the unit by operating the bottle filler. This will improve the ease of
replacing the filter.
4.
Remove the old filter by turning about ¼ turn clockwise (as viewed from
above) and pulling down.
a.
NOTE: There is no need to shut off the supply valve, as the filter
head has a built-in valve. If you are planning to leave the unit
without a filter cartridge for a protracted period of time, shut off the
supply valve.
5.
Install the new filter by pushing up and turning counterclockwise (as viewed
from above). Note the label orientation in Figure 5.
6.
Reinstall the skirt.
7.
Using a cup to block the water flow, bleed air out of the bottle filler by
activating the water flow until the air is purged out.
8.
Run the bottle filler for five minutes to properly flush the new filter.
E.4. FUSE REPLACEMENT
1.
Turn off power to unit
2.
Remove the skirt.
3.
Remove the (2) screws holding the lower circuit board cover to the
circuit board enclosure.
4.
Remove blown fuse and replace with a 5mm x 20mm, 10A, Fast
Blow, 250VAC rated fuse.
a.
NOTE: Haws PN: 0210000754
5.
Reinstall lower circuit board cover and skirt.
Figure 4: Strainer cleanout
Figure 5: Filter Replacement
Figure 6: Fuse Location