Installing and using the HAUSSMANN RIRI keypad 

The button  

  and the timeslots 

 

The HAUSSMANN RIRI keypad can be used with an external clock which enables  

  either the use of the button 

  in "unrestricted access" mode to open 1 door only. 

  or the programming codes associated with timeslots. 

 
 
Connect the clock to the        and       on the keypad. 
 
 
U

SE OF UNRESTRICTED ACCESS MODE

When the clock is on, each press on a button 

 on the keypad triggers door opening in 

"unrestricted access" mode. 
When the clock is off, the door remains shut and the red LED on the keypad lights up for 1 sec. 
 
U

SE OF CODES ASSOCIATED WITH TIMESLOTS

 
When the clock is on, the codes saved with the timeslots trigger door-opening. 
When the clock is off, the same codes do not open the door and the red LED on the keypad lights 
up for 1 sec. 
 
Important note: 

If you have programmed codes with timeslots, then the button 

 is disabled.  

To resume unrestricted access mode, delete codes 54 to 59. 

 
 

CONNECTION

 

TO

 

A

 

DOOR 

 

controlled by a lock mechanism:  

-

 

At rest, the lock mechanism keeps the door locked, 

-

 

When  the  relay  is  activated  by  the  central  unit,  current 
passes  through  it  and  the  lock  mechanism  opens  the 
door  (by  pressing  on  the  pushbutton  or  the  use  of  an 
authorised fob on the proximity reader). 

-

 

The power supplied to the electric lock mechanism must 
be  less  than  42  V  AC  or  60  V  DC.  If  the  power  supply 
voltage exceeds these values, use an intermediate relay 
(of the correct capacity) to control the electric lock. 

 

 

 

Controlled by a magnet lock 

-

 

At rest, power is supplied to the magnet and it keeps the 
door locked, 

-

 

When  the  relay  is  activated  by  the  central  unit,  the 
magnet's  power  supply  is  cut;  the  magnet  releases  the 
door  (by  pressing  on  the  push  button  or  the  use  of  an 
authorised badge on the proximity reader). 

-

 

The  power  supplied  to  the  electromagnet  must  be  less 
than  42  V  AC  or  60  V  DC.  If  the  power  supply  voltage 
exceeds  these  values,  use  an  intermediate  relay  (of  the 
correct capacity) to control the electric lock. 



 

 
 

Gâche 

C  R  T 

BP de porte 1 ou 2 

(NO) 

Alimentation 

Gâche 

Varistance 

BP1 

ou 

BP2 

 

 

 

 

 

 
 

Alimentation 

Ventouse 

C  R  T 

Varistance 

BP de porte 1 ou 2 

(NO) 

BP1 

ou 

BP2 

 

 

 

 

Intelligent Security & Fire Ltd.

Содержание RIRI

Страница 1: ...nn Riri coded keypad was designed to be adaptable to everyone s needs being simple to use on a daily basis this is the only coded keypad which complies fully with disability legislation Thanks to real time operation you can now manage it remotely from the www intratone com website in the ʺmanagement website tab Everything is arranged to help you save time on fitting it adapts to fit all facades bu...

Страница 2: ... external clock not supplied is made between the Hor Clock terminal and ground the door opens on pressing the button if no codes for timeslots predefined Configuration on the www intratone com website in the ʺmanagement websiteʺ tab the door opens on pressing the button Standards IP IP65 standard EC EN50082 1 EN 55022 standard The keypad must not be disposed of with unsorted urban waste but must b...

Страница 3: ...t Examples of possible configurations Door 1 Door 2 Alert D D EEN CIC12 D D PB1 DO C R T Door 1 PB Door 2 PB Door 1 Control Door 2 Control Door Control POW 12 24V DC 2A As close as possible to the unit Reader The central unit door control and the door 1 control on the Haussmann keypad work in the same way I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 4: ...or 2 Alert Example shown for door 1 Similar connection for doors 2 to 4 D D 11 12 13 14 17 18 19 C R T Door 1 Control Door 2 Control Door 1 Control POW 12 24V DC 2A door 1 and 2 3A with an extension board for doors 3 and 4 As close as possible to the unit Reader EEN CEN12 Warning In this configuration the relays and PB on the keypad cannot be used Use the ones on the EEN CEN12 central unit 15 16 D...

Страница 5: ... know a keypad code to open the door on working days Refer to the unrestricted access functionality on the management website Note The clock should not be connected to the and on the keypad This is only necessary with a stand alone keypad Caused by a contact on equipment for which you want to identify any malfunctioning Example The Central Locking Mechanism fails its contact sticks thereby closing...

Страница 6: ...emits 2 short beeps to confirm setting saved or a positive response 1 long beep in the event of an input or programming error After five seconds of no activity any incomplete programming sequence is deleted and the buzzer emits a beep In real time use This programming mode enables you to manage the master code and door opening time In stand alone keypad use This programming mode enables you to man...

Страница 7: ... to open doors 1 and 2 to open door 1 only at pre set times to open door 2 only at pre set times to open doors 1 and 2 only at pre set times 01 to 30 06 32 to 49 50 to 53 54 and 55 56 and 57 58 and 59 TYPE IN THE NUMBER OF DIGITS FOR THE CODE 4 to 8 digits TYPE IN THE CODE TO BE SAVED 0 to 9 A and B 2 beeps to confirm setting saved 1 long beep for an error NB Use the button inside the keypad to en...

Страница 8: ... TIME from 0 to 99 2 beeps to confirm setting saved Note The factory default setting for door 1 and 2 opening times is 5 sec Check stored codes Is the memory empty by typing in the code The beep will vary depending on the response ENTER PROGRAMMING MODE response 2 short beeps YES response 1 long beep response 1 short beep Completely empty no codes have been programmed Completely full all codes hav...

Страница 9: ... a lock mechanism At rest the lock mechanism keeps the door locked When the relay is activated by the central unit current passes through it and the lock mechanism opens the door by pressing on the pushbutton or the use of an authorised fob on the proximity reader The power supplied to the electric lock mechanism must be less than 42 V AC or 60 V DC If the power supply voltage exceeds these values...

Страница 10: ...V233 0009 CA Installing and using the HAUSSMANN RIRI keypad DIMENSIONS Drill holes Surface mount bracket Keypad without reader Keypad with reader Built in wall box I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 11: ...w the keypad to the wall holding the call panel against the wall 4 4 1 2 Clipping action 3 5 Unscrew until just touching Hook onto the fixing point Hold against the wall and lift up the keypad Hold the keypad down Screw the keypad to the wall Prepare the cavity for installation Check the dimensions carefully particularly the depth the box should be flush with the wall WATERTIGHT WALL seal 2 I n t ...

Страница 12: ...Page 12 13 EN V233 0009 CA Installing and using the HAUSSMANN RIRI keypad Clipping action 3 4 6 5 5 Wall Watertight seal held against the wall I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Страница 13: ...LEPHONE No CODE CODE No CODE CODE 01 02 32 03 33 04 34 05 35 Master 36 07 37 08 38 09 39 10 40 11 41 12 42 13 43 14 44 15 45 16 46 17 47 18 48 19 49 23 50 21 51 22 55 23 53 24 54 25 55 26 56 27 57 28 58 29 59 30 Key Door 1 Door 1 with Timeslot Door 2 Door 2 with Timeslot Door 1 and door 2 Door 1 and door 2 with Timeslot I n t e l l i g e n t S e c u r i t y F i r e L t d ...

Отзывы: