Warnings and Considerations
IMPORTANT!
Using this product in a manner other than outlined in this
document voids your warranty. Further, Control4 is NOT liable for any
damage incurred with the misuse of this product. See “Troubleshooting.”
IMPORTANT!
Do NOT use a power screwdriver to install this device. If you
do, you may overtighten the screws and strip them. Also, overtightening
the screws may interfere with proper button operation.
IMPORTANT!
This is an electronic device with intricate components.
Handle and install with care!
CAUTION!
Do not exceed the number of keypads per power supply as
indicated in Figures 2, 3, and 4 on the next page. Exceeding the maximum
number of keypads will result in overheating the wires and/or failed
devices.
Installation Instructions
CAUTION!
When wiring the keypad, make sure that either:
•
The Bus Power Supply is
not
powered on.
- OR -
•
The pluggable connector is disconnected from the Bus Power Supply.
1
Prepare the CAT5 cable for termination by stripping the outer sheath and
individual wires, then wire into the pluggable terminal block by using the
recommended wiring shown below.
Terminal
Wire
Color
GND
3 × Wire
Orange White + Green
White + Brown White
D+
1 × Wire
Blue
D-
1 × Wire
Blue White
V+
3 × Wire
Green + Brown
2
Wire the keypads as shown below.
Figure 1.
TIP
:
If you are using a Control4 push-on (screwless) faceplate in a
multi-gang installation, attach the black faceplate subplate to all of
the devices that will be installed into the wallbox
before
attaching
the devices to the wallbox. This will help ensure that all devices are
properly aligned and on the same plane after installation.
3
Fit the wires back into the wallbox.
4
Align the keypad to the wallbox (the model number label should be at the
bottom), then fasten it with the included screws.
IMPORTANT!
Tighten the screws until the back side of the yoke plate
is even with the wall surface, but no further. Overtightening can warp
the keypad and cause it to malfunction.
5
Install the top actuator bar, bottom sensor bar, and buttons following the
instructions in the
Keypad Buttons Installation Guide
.
6
Install the Control4 faceplate following the instructions in the
Faceplate
Installation Guide
or attach a standard decora-style faceplate.
KeyPad
KeyPad
V+
GND
D+
D-
V+
GND
D+
D-
T
o
Bus Ethernet
Gateway
T
o
Next Keypad
Supported Model
•
C4-KCB-XX Wired Configurable Keypad
Introduction
The Control4® Configurable Decora Wired Keypad is intended for use in a Control4
system. It installs in a standard US wallbox. Communication to the Control4 system
is via RS-485 protocol and wiring. For RS-485 wiring topologies, refer to the
document
Keypad Bus Wiring Recommendations
.
Box Contents
•
Configurable Decora Wired Keypad
•
Keycap Button Kit
•
Pluggable Terminal Block
• Warranty
Card
Specifications
The specifications are described below.
Model Number
C4-KCB-XX
Power Requirements
48VDC
Power Consumption
Maximum 24VDC 0.9W
Minimum 24VDC 0.5W
Maximum 48VDC 1.2W
Minimum 48VDC 0.7W
Environmental
Operational Temperature
32˚F - 104˚F (0˚C - 40˚C)
Humidity
5% to 95% non-condensing
Storage
-4˚F - 158˚F (-20˚C - 70˚C)
Miscellaneous
Control Communications
RS-485
Weight
0.1 lb. (0.045 kg)
Shipping Weight
0.3 lb. (0.14 kg)
Configurable
Decora
®
Wired
Keypad
Installation Guide