only
For access to these fans:
1. Turn off power.
2. Remove bottom display pans.
3. Disconnect fan from wiring harness.
4. Remove fan blade.
5. Lift fan plenum and remove screws holding bot-
tom of motor to fan basket.
6. Replace fan motor and blade.
7. Lower fan plenum.
8. Reconnect fan to wiring harness.
9. Turn on power.
10. Verify that motor is working and blade is
turning in the correct direction.
11. Close large air gaps under fan plenum. Warmer
air moving into refrigerated air reduces effective
cooling. If the plenum does not rest against the
case bottom without gaps, apply foam tape to the
bottom of the fan plenum to reduce improper air
movement, however defrost water should not be
blocked by fan plenum. Do NOT seal fan plenum
so that water can not drain.
12. Replace display pans. Bring merchandiser to
operating temperature before restocking.
Always disconnect the electrical power
at the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items
as fans, heaters, thermostats and lights.
Product will be degraded and may spoil if
allowed to sit in a non-refrigerated area.