P/N 0387183_V
6-1
Reach-In
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
REPLACING FAN MOTORS AND
BLADES
See cross section for location of evaporator fans.
Should it ever be necessary to service or replace the
fan motors or blades be certain that the fan blades
are re-installed correctly.
For access to RL / RM / RLN / RMN / RLNI / RLNIE
fans:
1. Turn off power.
2. Remove bottom display pans.
3. Disconnect fan from wiring harness.
4. Remove fan blade.
5. Remove screws holding fan motor/bracket assembly
to plenum and remove assembly.
6. Replace fan motor/bracket assembly and reinstall
screws.
7. Reinstall fan blade.
8. Reconnect fan to wiring harness.
9. Turn on power.
10. Verify that motor is working and blade is turning
in the correct direction.
11. Close large air gaps under fan plenum. Warmer
air moving into refrigerated air reduces effective
cooling. If the plenum does not rest against the
case bottom without gaps, apply foam tape to the
bottom of the fan plenum to reduce improper air
movement, however defrost water should not be
blocked by fan plenum. Do NOT seal fan plenum
so that water can not drain.
12. Replace display pans. Bring merchandiser to
operating temperature before restocking.
SERVICE
Hussmann recommends against frame heater
cycling with Innovator doors to prevent door
seals from freezing to the frames and tearing.
Always disconnect the electrical power
at the main disconnect when servicing or
replacing any electrical component. This
includes, but is not limited to, such items
as fans, heaters, thermostats and lights.
S er
vi c e #
MO.X
X X XX X X
XXXXXXX
Fan Assembly
Speed-Nut
Fan Blade
Screws
Motor
Airflow
Direction
Bracket
Plenum