Germany: HAUPA GmbH & Co. KG, Königstraße 165-169, D - 42853 Remscheid.
Phone: +49 (0)2191 8418-0, Fax: +49 (0)2191 8418-840, [email protected] • Errors and technical changes reserved.
...convincing solutions
english
Li-Ion Battery Manual Instruction
Panel Description:
1
㸬
Connect power shows
, comes a beeping, and the fan rotates 2 seconds.
2
㸬
Fully charged, it shows
and comes beeping every 3 seconds.
3
㸬
Unusual working == Too low voltage shows
and comes a beeping every second.
4
㸬
Unusual working == Unusual temperature shows
᧨
and comes a beeping every second.
5
㸬
The voltage is not rising after 10 minus charged. The battery is charged incompletely. The battery is faulty,
showing
and coming beeping every 2 seconds by a second.
Specification:
1.
The input power is external power DC24V 3A
ᇭ
2.
The charge voltage is 24V 2.5A
ᇭ
3.
When plug in the power, the panel shows
and comes a beeping.
4.
Uninstall the battery, the panel shows
and twinkles every second.
5.
Detect the battery voltage first and shows battery capacity rate when install battery.
6.
When battery charged completed, the panel shows
and comes beeping every 3 seconds.
7.
When the voltage is too low, the panel shows
and coms a beeping every second.
8.
When the temperature is too high, the panel shows
and comes a beeping every second.
9.
The maximum charge time is
120
minutes. After
12
0 minutes, the charger will stop charging regardless the battery
is charged completed.
10.
The full charged voltage for 18V Li-Ion battery is (5*4.3=21.5v); the voltage for 14.4V Li-Ion
is (4*4.3=v17.2v) (reference valve). The battery is coming with a protective plate which will stop charging
automatically when charged completely.
11.
The lowest battery voltage for 18V Li-Ion battery is (2.9*5=14.5v); and the 14.4v is (2.9*4=11.6v).
12.
It will stop charge when the battery temperature is higher than 65 degree centigrade.
13. The usual temperature for battery is between -20° to 65° centigrade when a fan is applied. The fan working voltage is 12V.
14. Under 90% battery capacity will carry in adding per 5%. Over 90% battery capacity will carry in adding per 1%.