12
HAUBER-Elektronik GmbH
15
Mounting and Dismounting
Mounting and Dismounting works at and with the Control may only be executed by an authorized expert,
familiar with the safety instructions for handling electrical components. For handling ATEX-certified controls
within explosion endangered surroundings the expert in addition has to be familiar with the safety
instructions relevant there.
Preconditions
Mounting surface clean and flat,
i.e. free from paint, rust, etc.
Threaded hole at the Mounting
surface:
Depth: 15 mm
Thread: M8
Unscrew housing cover from housing
base.
Allen wrench, SW8
Fasten control friction-locked at
the mounting surface by use of
allen screw and snap ring.
Allen wrench, SW6
Tighten housing cover on housing base
loosely by hand.
(Do not tilt the thread!)
Tighten housing cover with a tightening
torque = 5 Nm.
Torque wrench SW8
Working Steps
1.
2.
3.
Allen wrench, SW6, SW8
Torque wrench SW8
Allen screw M8x20
Snapring for M8
Tools and Materials
Note:
To avoid a possible galling of the housing cover with the housing base, it is
recommended before the final mounting to treat the housing cover thread with a mounting
paste for high-grade steel connections .
Before mounting and dismounting works the control has to be seperated from the mains!
Seperated plug and socket devices always have to be disconnected from the mains!
Otherwise danger of explosion because of sparkling, when operating ATEX-certified Types
663 in explosion endangered areas!
The control housing must be earthed via ist fastening - i. e. via machine earth or via a
seperate earth wire (PE)!
15.1
Fastening at the Mounting Surface
Fig. 11: Fastening at the mounting surface
Mounting Surface
zu
5 Nm
Fig. 12: Tightening housing cover with a torque
wrench