background image

INSTALLATION

6

Form No. TMSCEM-0615

General

THERM-Max Salamanders are shipped with most components

pre-assembled.  Care  should  be  taken  when  unpacking  the

shipping  carton  to  avoid  damage  to  the  unit  and  the

components enclosed. The salamander can be placed on a

countertop or mounted to a brick or cement wall. The following

installation instructions must be performed before operating the

salamander.

ELECTRIC SHOCk HAzARD:

• Unit  must  be  installed  by  a  qualified  electrician.

Installation must conform to all local electrical codes.

Installation  by  unqualified  personnel  will  void  unit

warranty and may lead to electric shock or burn, as well

as damage to unit and/or its surroundings.

• Unit is not weatherproof. Locate unit indoors where

ambient air temperature is a minimum of 21°C (70°F)

and a maximum of 29°C (85°F).

FIRE HAzARD:

• Install  unit  on  and  around  non-combustible  surfaces

with  non-combustible  construction  only.  Ensure

surface  construction  has  no  combustible  material

against  underside.  In  all  cases,  such  construction

shall extend at least 305 mm (12″) beyond equipment

on all sides.

• Locate unit a minimum of 51 mm (2″) from any walls. If

safe  distances  are  not  maintained,  discoloration  or

combustion could occur.

• Do  not  obstruct  air  intake  openings  or  air  exhaust

openings on outer housing of unit. Unit combustion or

malfunction may occur.

• Do not place anything on top of unit.

For  wall  mounting,  use  special  wall  mount  bracket

provided with unit only. Secure wall mount bracket to a

solid, non-combustible surface using appropriate hardware

for mounting surface and weight of unit.

Locate  unit  at  proper  counter  height  in  an  area  that  is

convenient for use. Location should be level to prevent unit

or its contents from falling accidentally and strong enough

to support the weight of the unit and contents.
Do not place anything on top of unit; doing so may subject

personnel to injury or damage unit.

NOTE: A qualified person must check possible placements of

the  salamander  to  ensure  that  the  proper  electrical
supply line is available.

1. Remove the unit from the shipping carton.

NOTE: To  prevent  delay  in  obtaining  warranty  coverage,

complete  online  warranty  registration.  See  the

IMPORTaNT OWNER INFORMaTION

section for details.

2. Remove tape and protective packaging from all surfaces

of unit.

3. Clean the unit thoroughly to remove all protective industrial

grease. 

NOTICE:

Use non-abrasive cleaners and cloths

only.

WARNING

CAUTION

4. Remove the transport locking screw used to secure the

upper housing during shipping. Discard the screw.

Transport locking Screw

Countertop Installation

1. Place the unit in the desired location.

• locate the unit directly underneath an exhaust hood if

possible.  This  will  ensure  total  suction  of  steam

produced during cooking.

• Make sure the unit is at the proper height in an area

convenient for use.

• Make sure the countertop is level and strong enough to

support the weight of the unit and food product.

• Make sure all the feet on the bottom of the unit are

positioned securely on the countertop with a minimum

of 51 mm (2″) between the unit and any wall.

Minimum Distance Requirement

2. level the unit by turning the leveling feet on each leg, if

necessary. When looking at the bottom of the unit, turning

the feet counterclockwise will lengthen the legs, and turning

the feet clockwise will shorten the legs.

3. Have a qualified electrician perform the necessary electrical

connections (refer to “Electrical Connections” in this section

for additional information).

Transport Locking

Screw

W

all

Countertop

51 mm (2″)

Содержание TMS Series

Страница 1: ... Regístrese en línea Fornello portatilei Serie TMS Manuale per l installazione e l uso P 46 Registratevi online Salamander Serien TMS Installations und Bedienungshandbuch P 13 Registrieren Sie sich online Salamander Séries TMS Manuel d installation et d utilisation P 35 S inscrire en ligne Register Online see page 2 hatcocorp com Original Instructions Originalanleitung Instrucciones originales Ins...

Страница 2: ...ng Chart 5 Dimensions 5 Installation 6 General 6 Countertop Installation 6 Wall Installation 7 Electrical Connections 7 Operation 8 General 8 Control Panel 8 Operating the Salamander 9 Maintenance 10 General 10 Daily Cleaning 10 Troubleshooting Guide 11 International Limited Warranty 12 Service Information 12 IMPORTANT OWNER INFORMATION Record the model number serial number voltage and purchase da...

Страница 3: ...codes Installation by unqualified personnel will void unit warranty and may lead to electric shock or burn as well as damage to unit and or its surroundings Units supplied without an electrical plug require field installation of proper plug Plug must be properly grounded and of correct voltage size and configuration for electrical specifications of unit Contact a qualified electrician to determine...

Страница 4: ...ements are strategically positioned inside the moveable upper housing to reduce the transfer of heat to the surrounding area The HOlD function on TMS 1H models is ideal for keeping foods hot or reheating foods a removeable cooking grate and drip tray allows for easy cleanup The unique features and flexibility of the THERM Max Salamander make it easy to operate energy efficient and highly functiona...

Страница 5: ... lbs Model Width A Depth B Height C Footprint Width D Footprint Depth E Cooking Width F Cooking Depth G Cooking Height H TMS 1H and TMS 1 600 mm 23 5 8 510 mm 20 1 8 546 mm 21 1 2 520 mm 20 1 2 380 mm 15 540 mm 21 1 4 365 mm 14 5 16 50 to 212 mm 2 to 8 1 4 SPECIFICATIONS Electrical Rating Chart NOTE Shipping weight includes packaging Dimensions Form No TMSCEM 0615 5 Front View Side View A F F F D ...

Страница 6: ...hould be level to prevent unit or its contents from falling accidentally and strong enough to support the weight of the unit and contents Do not place anything on top of unit doing so may subject personnel to injury or damage unit NOTE A qualified person must check possible placements of the salamander to ensure that the proper electrical supply line is available 1 Remove the unit from the shippin...

Страница 7: ...n for electrical specifications of unit Contact a qualified electrician to determine and install proper electrical connection When installing a hardwired unit a 2 pole or 3 pole switch depending on unit must be installed between unit and main electrical supply The switch must be rated properly and have contacts with a minimum opening distance of 3 mm 1 8 Unit must be connected to an equipotential ...

Страница 8: ...king Grate Control Panel Height Gauge Heating Mode Selector The heating mode selector determines the function of the overhead elements in the salamander The operation of this knob is slightly different for each model TMS 1H Models The heating mode selector on TMS 1H models has five positions and two functions COOK and HOlD The following are descriptions of the five positions OFF No elements select...

Страница 9: ... product onto the cooking grate 3 Turn the heating mode selector to the desired COOK function The ON indicator light will illuminate 4 Turn the timer knob clockwise to the desired cooking time The appropriate lEFT and or RIGHT indicator light s will illuminate to indicate which elements are selected and heating Operating the Salamander NOTICE Place food product onto cooking grate Lower upper housi...

Страница 10: ...perate safely in Hatco equipment This unit has no user serviceable parts If service is required on this unit contact an Authorized Hatco Service Agent or contact the Hatco Service Department at 414 671 6350 fax 414 671 3976 WARNING Daily Cleaning To preserve the finish of the unit as well as maintain performance it is recommended that the unit be cleaned daily Use non abrasive cleaners and cloths ...

Страница 11: ... to trip contact an authorized Hatco Service agent or Hatco for assistance Timer or Heat Mode switch defective Contact an authorized Hatco Service agent or Hatco for assistance Form No TMSCEM 0615 11 TROUBLESHOOTING GUIDE This unit must be serviced by qualified personnel only Service by unqualified personnel may lead to electric shock or burn WARNING ELECTRIC SHOCk HAzARD Turn OFF power switch unp...

Страница 12: ...or application of improper voltage 2 LIMITATION OF REMEDIES AND DAMAGES Hatco s liability and Buyer s exclusive remedy hereunder will be limited solely to replacement of part or Product using at Hatco s option new or refurbished parts or Product by Hatco or a Hatco authorized service agency with respect to any claim made within the applicable warranty period referred to above Hatco reserves the ri...

Страница 13: ...iel Alternating Current Corriente alterna Courant Alternatif Water Fill Low Water Llenado de agua bajo nivel de agua Remplir d eau Bas Niveau d eau Humidity Humidity Cycle Humedad ciclo de humedad Humidité Cycle Humidité Symbolerklärung Identificazione del simbolo Uitleg bij de symbolen Achtung Heiße Oberfläche Attenzione superficie calda Let op heet oppervlak Einschalten Acceso Ingeschakeld Aussc...

Отзывы: