Form No. GRSSRDLM-0607

11

HATCO LIMITED WARRANTY

1. PRODUCT WARRANTY

Hatco warrants the products that it manufactures 
(the “Products”) to be free from defects in materials
and workmanship, under normal use and service, for
a period of one (1) year from the date of purchase
when installed and maintained in accordance with
Hatco’s written instructions or 18 months from the
date of shipment from Hatco. Buyer must establish
the product’s purchase date by returning Hatco’s
Warranty Registration Card or by other means 
satisfactory to Hatco in its sole discretion.

Hatco warrants the following Product components to
be free from defects in materials and workmanship
from the date of purchase (subject to the foregoing
conditions) for the period(s) of time and on the
conditions listed below:

a) One (1) Year Parts and Labor PLUS One (1)

Additional Year Parts-Only Warranty:

Toaster Elements (metal sheathed)
Drawer Warmer Elements (metal sheathed)
Drawer Warmer Drawer Rollers and Slides
Food Warmer Elements (metal sheathed)
Display Warmer Elements (metal sheathed 
air heating)
Holding Cabinet Elements (metal sheathed 
air heating)
Built-In Heated Well Elements (metal sheathed)

b) One (1) Year Parts and Labor PLUS Four 

(4) Years Parts-Only Warranty on pro-rated
terms that Hatco will explain at Buyer’s
request: 

3CS and FR Tanks

c) One (1) Year Parts and Labor PLUS Nine 

(9) Years Parts-Only Warranty on:

Electric Booster Heater Tanks
Gas Booster Heater Tanks 

THE FOREGOING WARRANTIES ARE EXCLUSIVE
AND IN LIEU OF ANY OTHER WARRANTY,
EXPRESSED OR IMPLIED, INCLUDING BUT NOT
LIMITED TO ANY IMPLIED WARRANTY OF
MERCHANTABILITY

OR FITNESS FOR A

PARTICULAR PURPOSE OR PATENT OR 
OTHER INTELLECTUAL PROPERTY RIGHT
INFRINGEMENT. Without limiting the generality of
the foregoing, SUCH WARRANTIES DO NOT
COVER: Coated incandescent light bulbs,
fluorescent lights, lamp warmer heat bulbs, glass
components, Product failure in booster tank, fin tube
heat exchanger, or other water heating equipment,
caused by liming, sediment buildup, chemical attack
or freezing, Product misuse, tampering or
misapplication, improper installation or application of
improper voltage.

2. LIMITATION OF REMEDIES AND
DAMAGES

Hatco’s liability and Buyer’s exclusive remedy
hereunder will be limited solely, at Hatco’s option, to
repair or replacement by a Hatco-authorized service
agency (other than where Buyer is located outside of
the United States, Canada, United Kingdom or
Australia in which case Hatco’s liability and Buyer’s
exclusive remedy hereunder will be limited solely to
replacement of part under warranty) with respect to
any claim made within the applicable warranty
period referred to above. Hatco reserves the right to
accept or reject any such claim in whole or in part.
Hatco will not accept the return of any Product
without prior written approval from Hatco, and all
such approved returns shall be made at Buyer’s sole
expense. HATCO WILL NOT BE LIABLE, UNDER
ANY CIRCUMSTANCES, FOR CONSEQUENTIAL
OR INCIDENTAL DAMAGES, INCLUDING BUT
NOT LIMITED TO LABOR COSTS OR LOST
PROFITS RESULTING FROM THE USE OF OR
INABILITY TO USE THE PRODUCTS OR FROM
THE PRODUCTS BEING INCORPORATED IN OR
BECOMING A COMPONENT OF ANY OTHER
PRODUCT OR GOODS.

Содержание GLO-RAY GRSSR20-DL Series

Страница 1: ...of this manual please bring it to the attention of your supervisor Do not operate this equipment unless you have read and understood the contents of this manual Este manual contiene importante información sobre seguridad concerniente al mantenimiento uso y operación de este producto Cualquier falla en el seguimiento de las instrucciones contenidas en este manual puede resultar en un serio daño Si ...

Страница 2: ...istance available in the United States and Canada by calling 800 558 0607 Additional information can be found by visiting our web site at www hatcocorp com Hatco Glo Ray Round Heated Stone Shelf with Display Lamp is designed to keep hot food at optimum serving temperatures and to enhance restaurant decor Heat is focused directly above and below providing effective insulation for prolonged serving ...

Страница 3: ...20 DL standard watt heat lamps 250 watt bulb must have a minimum of 16 406 mm above a flammable surface If safe distances are not maintained discoloration or combustion could occur GRSSR20 DLH high watt heat lamps 375 watt bulb must have a minimum of 27 686 mm above a flammable surface If safe distances are not maintained discoloration or combustion could occur For safe and proper operation do not...

Страница 4: ...ntally falling and strong enough to support the weight of the unit and food CAUTIONS Unit is not weatherproof For safe and proper operation locate the unit indoors where the ambient air temperature is constant and is a minimum of 70 F 21 C Some exterior surfaces on the unit will get hot Use caution when touching these areas to avoid injury NOTICES Use only non abrasive cleaners Abrasive cleaners c...

Страница 5: ...n Each foodwarmer comes equipped with an On Off lighted rocker switch adjustable thermostat and 6 1829 mm power cord with attached plug GRSSR20 DL Standard Wattage Standard wattage models DL feature a 250 watt upper infrared heat bulb GRSSR20 DLH High Wattage High wattage models DLH feature a 375 watt upper infrared heat bulb Figure 1 Model GRSSR20 DL Figure 2 Model Designation GR SS R 20 DL H 775...

Страница 6: ... not match contact a qualified electrician to determine the proper voltage and size and install the proper electrical outlet ELECTRICAL RATING CHART Figure 3 Plug Configuration Receptacle not supplied by Hatco Figure 4 Dimensions NEMA 5 15P Dia 20 508 mm 2 5 8 65 mm DIMENSIONS 34 1 2 876 mm Standard Watt 45 1 2 1156 mm High Watt Model Voltage Wattage Amperage Plug Configuration Shipping Weight GRS...

Страница 7: ...r hoods and air conditioning ducts CAUTION Unit is not weatherproof For safe and proper operation the unit must be located indoors where the ambient air temperature is a minimum of 70 F 21 C and a maximum of 85 F 29 C WARNING For safe and proper operation the unit must be located at 1 25 4 mm distance from combustible walls and materials If safe distances are not maintained discoloration or combus...

Страница 8: ...rature is a minimum of 70 F 21 C WARNING The Glo Ray Round Heated Stone Shelf with Display Lamp is not waterproof To avoid electrical shock or personal injury DO NOT submerge in water Do not operate if it has been submerged in water 1 Plug unit into a properly grounded electrical outlet of the correct voltage size and plug configuration See SPECIFICATIONS for details 2 Place the Power ON OFF Switc...

Страница 9: ...t until scratch disappears Blend area in with abrasive finishing pad WARNING If service is required on this unit contact your Authorized Hatco Service Agent or contact the Hatco Service Department at 800 558 0607 or 414 671 6350 fax 800 690 2966 or International fax 414 671 3976 WARNING This product has no user serviceable parts To avoid damage to the unit or injury to personnel use only Authorize...

Страница 10: ...e a bulb place the switch in the OFF position and allow the bulb to cool completely 2 Bulbs have a threaded base Unscrew the heat bulb counterclockwise from the unit and replace with a new bulb The following replacement bulbs are available from the factory or Hatco Authorized Parts Distributor DL standard wattage 250 Watt 120V Red Coated 02 30 068 00 250 Watt 120V Clear Coated 02 30 069 00 250 Wat...

Страница 11: ...ollow the directions on the product labels If these methods fail to produce acceptable results contact the Swanstone representative in your area Hard to Remove Stains For hard to remove stains abrasive cleaners recommended include Ajax Comet Bon Ami or Bar Keeper s Friend Also the use of an abrasive pad such as Scotch Brite NOTE Do not use steel wool or metal scouring pads Mineral Based Stains For...

Страница 12: ...s Block air currents or relocate unit Upper infrared heat bulb does not light Bulb is defective Replace heat bulb Unit not working at all Unit not plugged in Plug unit into proper power supply Unit not turned on Place ON OFF switch in the ON position ON OFF switch is not functioning Contact Authorized Service Agent for repair Base heating element is burned out Contact Authorized Service Agent for ...

Страница 13: ... OTHER WARRANTY EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR PATENT OR OTHER INTELLECTUAL PROPERTY RIGHT INFRINGEMENT Without limiting the generality of the foregoing SUCH WARRANTIES DO NOT COVER Coated incandescent light bulbs fluorescent lights lamp warmer heat bulbs glass components Product failure in booster ta...

Страница 14: ...Form No GRSSRDLM 0607 12 NOTES ...

Страница 15: ......

Страница 16: ...is 314 535 2222 NEBRASKA Anderson Electric Omaha 402 341 1414 NEVADA Burney s Commercial Las Vegas 702 736 0006 Hi Tech Commercial Service N Las Vegas 702 649 4616 NEW JERSEY Jay Hill Repair Fairfield 973 575 9145 Service Plus Flanders 973 691 6300 NEW YORK Acme American Repairs Inc Brooklyn 718 456 6544 Alpro Service Co Brooklyn 718 386 2515 Appliance Installation Buffalo 716 884 7425 Northern Pa...

Отзывы: