OPTIONS AND ACCESSORIES
Form No. GRSDCEM1-0514
17
Digital Temperature Controller
Units may be equipped with an optional digital temperature
controller that regulates and displays the base temperature(s).
Use the following procedures to operate the digital temperature
controller.
NOTE: This option is factory-installed only, not available for
retrofit.
NOTE: Units manufactured for use outside the United States
and Canada will have digital temperature controllers
that indicate temperature in Celsius (°C).
Digital Temperature Controller
1. Move the unit Power I/O (on/off) switch(es) to the I (on)
position.
• The digital temperature controller will energize and the
current temperature of the heated base(s) will appear
on the display.
CAUTION! Some exterior surfaces on
the unit will get hot. Use caution when touching
these areas.
• The phrase “out 1” will appear in the upper left corner of
the display to show that the base is in heat mode.
2. Press and release the
key. The current setpoint
temperature will be shown on the display and ”out 1” will
flash in the upper left corner.
3. Press the
key or
key within 15 seconds to
change the setpoint temperature. If no key is pressed
within 15 seconds, the display will revert to the current
temperature of the heated base(s)
4. Press the
key or wait 15 seconds to lock in the new
setpoint temperature. The setpoint temperature range of
the controller is from room temperature to the maximum
operating temperature of the unit.
Locking/Unlocking the Digital Temperature
Controller
The keys on the digital temperature controller can be locked to
prevent unauthorized changes to the settings.
To lock the keys of the digital temperature controller:
• Press and hold both the
key and
key at the
same time for over two seconds. The message “Loc” will
appear on the display.
To unlock the keys of the digital temperature controller:
• Press and hold both the
key and
key at the
same time until the message “UnL” appears on the display.
Down Arrow
Key
Up Arrow
Key
“out 1”
Celsius
Symbol
SET
Key
Sneeze Guards
Optional sneeze guards are available for all models. GRSDH
models can be fitted with sneeze guards above each shelf on
both sides of the unit. GRSDS and GRSDS/H models can be
fitted with sneeze guards above each shelf on the customer
side of the unit only. Use the following procedure to install
sneeze guards.
1. Remove the screws from the face of the unit that align with
the holes in the sneeze guard.
2. align the holes on the sneeze guard with the screw holes
on the unit.
3. Insert the screws removed in step #1 through the sneeze
guard and into the unit.
4. Tighten the screws until the sneeze guard is secure. Do
not over-tighten the screws.
GRSDS Model Sneeze Guard Installation
Display Sign Holder
a display sign holder (sign not included) is available
for installation on the top or intermediate shelf. The sign holder
is installed by simply attaching the magnetic side of the sign
holder to the desired shelf.
Display Sign Holder
Magnet
Sign Holder
Sneeze Guard
Screw