Infinite Switch
Use the following procedure to install an infinite switch. An
infinite switch needs to be installed into an approved electrical
box/enclosure (not supplied) by a qualified electrician.
WARNING
ELECTRIC SHOCK HAZARD: Turn OFF power switch,
disconnect unit from power source, and allow unit to
cool before performing any cleaning, adjustments, or
maintenance.
NOTICE
To prevent premature failure of components due to
excessive heat, remote mounted control switches must be
installed outside the strip heater heat zone.
1. Verify unit is off and disconnected from the power source.
2. Install the infinite switch. Refer to the wiring diagram for
proper electrical connections. Make sure the switch is
installed with the “H1” terminal oriented on top. This will
ensure that the switch functions match the markings on
the switch label.
• Power In: L1 and L2
• To Heating Element: H1 and H2
NOTE: The terminals on the infinite switch are specially
designed, high-temperature rated terminals that do not
require solder connections.
NOTICE
The infinite switch must be installed using the terminals
and wires supplied with the switch. Failure to use the
supplied Genuine Hatco Replacement Parts will void all
warranties and may damage the equipment.
LINE
220-230V
220-230V
LOAD
Infinite Switch Wiring Diagram (rear view)
NOTE: Make sure the switch is installed with the “H1” terminal
oriented on top (“12 o’clock” position), as shown above.
This will ensure that the switch functions match the
markings on the switch label.
Infinite Switch Kit Part Numbers
Part Number
Voltage
R02.19.019.00
240 volt
OPTIONS AND ACCESSORIES
Sneeze Guards
Optional sneeze guards are available for aluminum models only.
Sneeze guards not field retrofittable. They are available in sizes
of 238 mm (9-3/8″) and 356 mm (14″). Sneeze guards can be
installed on either one side or both sides of the unit.
To install a sneeze guard:
1. Remove the protective paper from the sneeze guard.
2. Assemble each tab screw through the top of the sneeze
guard and through the support bar. Loosely thread an
acorn nut onto each of the tab screws below the support
bar.
3. Lift the sneeze guard assembly and carefully slide each
of the tab screws that are loosely attached to the sneeze
guard into the channel on the unit.
4. Align each end of the sneeze guard with the ends of the
unit and then tighten the acorn nuts to secure the sneeze
guard in position. Do not over-tighten the acorn nuts.
CAUTION - HO
T
GLO-RAY
Foodwarm
er
HATCO CORP
. MILWAUK
EE, WI U.S
.A.
ON
OFF O
PARTS & S
ERVICE
ASSISTANC
E
WWW.HATC
OCORP.CO
M
800-558-06
07
HATCO CORP
. MILWAUKEE, WI U.S.A
.
ON
OFF O
Tab Screw
Acorn Nut
Support Bar
Sneeze Guard
Channel
Installing Sneeze Guards
Содержание GLO-RAY GR-18
Страница 36: ...GRM_CN 0818 36 90 C 194 F 15 No 14 AWG 20 No 12 AWG 20 25 No 10 AWG 25 30 No 8 AWG 20 20...
Страница 37: ...GRM_CN 0818 37 Hatco RMB CE...
Страница 38: ...GRM_CN 0818 38 Glo Ray 30 I O 15 12 2 1 I O I 15 20 2 I O I I O 0 I O 1 I O O O 2 I O O...
Страница 39: ...GRM_CN 0818 39 1 2 3 4 NSF 1 2 Hatco NSF 220 230 Hatco P N 02 30 058 00 Glo Ray 0512 6732 5091...
Страница 40: ...GRM_CN 0818 40 Hatco Hatco Hatco Hatco Hatco Hatco www hatcocorp com Hatco 0512 6732 5091 infocn hatcocorp com...