WARNING

FIRE HAZARD: Do not use an extension cord. If power 

cord is too short, contact a qualified electrician to 

determine and install proper voltage and size electrical 

receptacle near unit.
Make sure all operators have been instructed on the safe 

and proper use of the unit.
This unit is not intended for use by children or persons 

with reduced physical, sensory, or mental capabilities. 

Ensure proper supervision of children and keep them 

away from the unit.
This unit has no “user-serviceable” parts. If service 

is required on this unit, contact an Authorized Hatco 

Service Agent or contact the Hatco Service Department at  

800-558-0607 or 414-671-6350.

CAUTION

BURN HAZARD: Some exterior surfaces on unit will get 

hot. Avoid unnecessary contact with unit.
Locate unit in an area that is convenient for use. The 

location should be level and strong enough to support the 

weight of the unit and contents.
Do not move or relocate unit for cleaning. Unit is bulky 

and heavy.
Do not place anything on top of unit; doing so may subject 

personnel to injury or could damage unit.
Do not store any materials or items inside unit when not 

in use.
Never use steel pads, wire brushes, or scrapers to clean 

unit.

NOTICE

Do not locate unit in an area subject to ambient 

temperatures above 100°F (38°C). Doing so will damage 

unit and void warranty.
Unit must be level for self-closing doors to function 

properly.
Do not lay unit on its side in any direction. Damage to unit 

could occur.
Damage to any countertop material caused by heat 

generated from Hatco equipment is not covered under 

the Hatco warranty. Contact manufacturer of countertop 

material for application information.
Use non-abrasive cleaners and cloths only. Abrasive 

cleaners and cloths could scratch finish of unit, marring its 

appearance and making it susceptible to soil accumulation.
Clean unit daily to avoid malfunctions and maintain 

sanitary operation.

WARNING

ELECTRIC SHOCK HAZARD:

  •  Plug unit into a properly grounded electrical receptacle 

of the correct voltage, size, and plug configuration. If 

plug and receptacle do not match, contact a qualified 

electrician to determine and install proper voltage and 

size electrical receptacle.

 • Turn OFF power switch, unplug power cord, and 

allow unit to cool before performing any cleaning, 

adjustments, or maintenance.

  •  DO NOT submerge or saturate with water. Unit is not 

waterproof. Do not operate if unit has been submerged 

or saturated with water.

  •  Unit is not weatherproof. Locate unit indoors where 

ambient air temperature is a minimum of 70°F (21°C).

  •  Do not steam clean or use excessive water on unit.
  •  This unit is not “jet-proof” construction. Do not use 

jet-clean spray to clean this unit.

  •  Do not clean unit when it is energized or hot.
  •  Do not pull unit by power cord.
  •  Discontinue use if power cord is frayed or worn.
  •  Do not attempt to repair or replace a damaged power 

cord. Cord must be replaced by an Authorized Hatco 

Service Agent or a person with similar qualifications.

  •  Do not clean unit with metal scouring pads. Metal pieces 

can break off pad and touch electrical components, 

creating risk of electric shock.

  •  This unit must be serviced by qualified personnel only. 

Service by unqualified personnel may lead to electric 

shock or burn.

  • Use only Genuine Hatco Replacement Parts when 

service is required. Failure to use Genuine Hatco 

Replacement Parts will void all warranties and may 

subject operators of the equipment to hazardous 

electrical voltage, resulting in electrical shock or burn. 

Genuine Hatco Replacement Parts are specified to 

operate safely in the environments in which they are 

used. Some aftermarket or generic replacement parts 

do not have the characteristics that will allow them to 

operate safely in Hatco equipment.

EXPLOSION HAZARD: Do not store or use gasoline or 

other flammable vapors or liquids in the vicinity of this or 

any other appliance.
Install unit in accordance with installation instructions in 

this manual.
This unit is not designed for long-term food holding.  The 

holding time is programmable for up to 45 minutes upon 

placement of each order in a locker.  Manage or dispose 

of food products held for longer than safe holding time in 

accordance with all local food code requirements.
Use extreme caution when moving and tipping unit during 

installation. Size and weight of unit create significant tip 

and pinch point hazards. Remain aware and keep clear of 

unit/pinch points while tipping to avoid serious injury.

Read the following important safety information before using this equipment to avoid  

serious injury or death and to avoid damage to equipment or property

.

SAVE THESE INSTRUCTIONS

Содержание F2GBP Series

Страница 1: ...dad concerniente al mantenimiento uso y operaci n de este producto Si usted no puede entender el contenido de este manual por favor pregunte a su supervisor Almacenar este manual en una localizaci n s...

Страница 2: ...Mount Models 8 Installing Built In Models 9 Operation 10 General 10 Placing an Order 10 Picking up an Order 11 Clear a Single Order 12 Change a Locker s Heated Ambient Setting 12 Change All Lockers He...

Страница 3: ...le Turn OFF power switch unplug power cord and allow unit to cool before performing any cleaning adjustments or maintenance DO NOT submerge or saturate with water Unit is not waterproof Do not operate...

Страница 4: ...AND ACCESSORIES section of this manual for all of the available options and accessories F2GP 21 F2GP 22 and F2GP 12 Models Countertop Models The F2GP 21 F2GP 22 and F2GP 12 models are designed for co...

Страница 5: ...d size electrical receptacle NEMA 5 15P Plug Configurations NOTE Receptacle not supplied by Hatco NOTE The specification label is located next to the power cord See the label for the serial number and...

Страница 6: ...View Side View A B C SPECIFICATIONS Model Width A Depth B Height C F2GP 21 C 77 3 4 1974 mm 24 11 16 626 mm 16 7 8 428 mm F2GP 22 C 77 3 4 1974 mm 24 11 16 626 mm 31 3 4 804 mm F2GP 12 C 44 1 8 1121...

Страница 7: ...mm 2 1 8 54 mm C A B Model Width A Depth B Height C F2GBP 12 C 44 1 8 1121 mm 24 11 16 626 mm 34 3 4 883 mm F2GBP 14 C 44 1 8 1121 mm 24 11 16 626 mm 64 3 8 1635 mm F2GBP 21 C 77 3 4 1974 mm 24 11 16...

Страница 8: ...the model and installation type Installing Countertop Models Installing Floor Mount Models Installing Built In Models Installing Countertop Models 1 Place the unit in the desired location Locate the u...

Страница 9: ...to 78 1 2 1981 1994 mm 32 to 32 1 2 812 826 mm A B Wall Cutout Dimensions 2 Remove the access panels on the bottom and top of each locker column on the customer side by removing the screws 3 Lift the...

Страница 10: ...ON BURN HAZARD Some exterior surfaces on the unit will get hot Use caution when touching these areas 2 For lockers with HEATED mode enabled allow the heated lockers 30 minutes to reach operating tempe...

Страница 11: ...e following procedure to unlock and remove food from a locker on the customer side A general outline of this procedure should be provided to the customer 1 On the Orders Ready screen touch the name th...

Страница 12: ...rature Ambient selection will turn the heating elements off for that locker No icon will appear next to the locker on the Select Lockers Screen 5 Touch to return to the Select Lockers screen Change Al...

Страница 13: ...Lockers screen touch for system settings 2 Enter the Passcode and touch ENTER to access the System Settings screen The factory set Passcode is 88888 3 Touch CLEAR ORDERS All orders will be cleared on...

Страница 14: ...he USB slot The software folder must be in the root folder on the USB drive The software will update automatically when the USB drive is inserted USB Slot Touchscreen Controller USB Slot 3 After the t...

Страница 15: ...e environments in which they are used Some aftermarket or generic replacement parts do not have the characteristics that will allow them to operate safely in Hatco equipment This unit has no user serv...

Страница 16: ...Service by unqualified personnel may lead to electric shock or burn WARNING ELECTRIC SHOCK HAZARD Turn OFF power switch unplug power cord and allow unit to cool before performing any cleaning adjustm...

Страница 17: ...on either side but needs to be installed on the bracket under the touchscreen controller as shown below Side Shelf Mounting Locations Side Shelf Side Shelf Installation 2 Install the circle shelf bra...

Страница 18: ...xt indicates locker is overtime White text indicates time food is in locker Settings Locker is disabled Order Code Locker in HEATED mode Error Description of Select Lockers Screen NOTE If the order co...

Страница 19: ...armer Elements metal sheathed Drawer Warmer Drawer Rollers and Slides Food Warmer Elements metal sheathed Display Warmer Elements metal sheathed air heating Holding Cabinet Elements metal sheathed air...

Страница 20: ...lation des mod les encastr s 28 Mode d emploi 29 G n ralit s 29 Passer une commande 29 R cup rer une commande 30 Effacer une commande unique 31 Modifier le r glage chauff temp rature ambiante d un cas...

Страница 21: ...AVERTISSEMENT DANGER DE D CHARGE LECTRIQUE Brancher l appareil sur une prise de courant avec terre de tension de format et de configuration des broches corrects Si la fiche et la prise ne se correspon...

Страница 22: ...21 F2GP 22 et F2GP 12 mod les sur comptoir Les mod les F2GP 21 F2GP 22 et F2GP 12 sont con us pour tre utilis s sur un comptoir Ces mod les comportent deux ou quatre casiers de haut avec une ou deux c...

Страница 23: ...F2GBP 21 et F2GBP 22 mod les encastr s Les mod les F2GBP 12 F2GBP 14 F2GBP 21 et F2GBP 22 sont con us pour tre encastr s dans un mur Ces mod les comportent une ou deux colonnes et ont une hauteur de...

Страница 24: ...Reportez vous l tiquette du num ro de s rie et les donn es lectriques de l appareil Tableau des valeurs nominales lectriques Mod les mont s sur un comptoir Tableau des valeurs nominales lectriques Mod...

Страница 25: ...les mont s au sol Vue de face Vue de c t A B C Mod le Largeur A Profondeur B Hauteur C F2GP 21 C 1974 mm 77 3 4 626 mm 24 11 16 428 mm 16 7 8 F2GP 22 C 1974 mm 77 3 4 626 mm 24 11 16 804 mm 31 3 4 F2...

Страница 26: ...3 mm 15 16 54 mm 2 1 8 A B Mod le Largeur A Profondeur B Hauteur C F2GBP 12 C 1121 mm 44 1 8 626 mm 24 11 16 883 mm 34 3 4 F2GBP 14 C 1121 mm 44 1 8 626 mm 24 11 16 1635 mm 64 3 8 F2GBP 21 C 1974 mm 7...

Страница 27: ...et du type d installation Installation des mod les mont s sur un comptoir Installation des mod les mont s au sol Installation des mod les encastr s Installation des mod les mont s sur un comptoir 1 P...

Страница 28: ...mensions de la d coupe du mur 2 Retirez les vis des panneaux d acc s situ s en haut et en bas de chaque colonne de casiers c t client puis retirez ces panneaux 3 Soulevez l appareil et placez le avec...

Страница 29: ...es de l appareil deviennent chaudes Toucher ces zones de l appareil avec pr caution 2 Pour les casiers dont le mode CHAUFF est activ Laissez aux casiers chauff s 30 minutes pour atteindre leur temp ra...

Страница 30: ...ur d verrouiller un casier et en retirer de la nourriture c t client Les grandes lignes de cette proc dure doivent tre fournies au client 1 Sur l cran Commandes pr tes appuyez sur le nom sous lequel l...

Страница 31: ...ne ic ne n appara tra c t du casier sur l cran de s lection des casiers 5 Appuyez sur pour revenir l cran de s lection des casiers Modifier le r glage chauff temp rature ambiante de tous les casiers 1...

Страница 32: ...1 Sur l cran de s lection des casiers appuyez sur pour acc der aux param tres du syst me 2 Saisissez le code d acc s et appuyez sur ENTER entr e pour acc der l cran des param tres du syst me Le code...

Страница 33: ...l dans la prise USB Le dossier du logiciel doit se trouver dans le dossier racine de la cl USB Le logiciel se met automatiquement jour lorsque la cl USB est ins r e Prise USB Panneau de commande cran...

Страница 34: ...dans lesquels elles sont utilis es Certaines pi ces de rechange g n riques ou de second march ne pr sentent pas les caract ristiques leur permettant de fonctionner sans danger dans la mat riel Hatco C...

Страница 35: ...l appareil en basculant l interrupteur d alimentation sur arr t puis nouveau sur marche Si le probl me persiste contactez une agence de service apr s vente agr e ou Hatco pour obtenir de l aide GUIDE...

Страница 36: ...ode QR Utilisez les formats de donn es suivants lors de la cr ation d un code QR en fonction du type de code cr er Format de donn es pour le placement d une commande par l op rateur ORDER CREATE ORDER...

Страница 37: ...c t client l aide du scanner de code QR Les grandes lignes de cette proc dure doivent tre fournies au client 1 Sur l cran Commandes pr tes scannez le code QR Si le nom du client ne figure pas sur la...

Страница 38: ...la tablette circulaire 3 Ins rez la tablette lat rale sur les supports de la tablette circulaire Tablette lat rale Support de la tablette lat rale Installation de la tablette lat rale 4 Fixez la tabl...

Страница 39: ...enveloppe m tallique l ments de pr sentation du r chaud enveloppe m tallique air chauffant l ments des armoires de stockage enveloppe m tallique air chauffant l ments de puits chauffants s ries HW HWB...

Страница 40: ...ire Plattsburgh 800 634 5005 Duffy s AIS Sauquoit 800 836 1014 J B Brady Inc Syracuse 315 422 9271 NORTH CAROLINA Authorized Appliance Charlotte 704 377 4501 OHIO Akron Canton Comm Svc Inc Akron 330 7...

Отзывы: