EN
Installation instructions, for professionals only
p. 17/34
L1L2
N
L3
U V
N
W
r r
w
w
ϑ
ϑ
U V
N
W
W
230V 1N~
N
V
N
U
L
PE
N
N V1W
m
N U1W
M
4
4.6. Connection diagram for 230V 1N~
Fig. 9
2
3
5
1
Connection diagram for the Concept R mini combi 3.5 kW, 4.5 kW,
6.0 kW and 7.5 kW
(CP-RMC-35 / CPC-RM-45 / CR-RMC-60 / CP-RMC-75)
1
Sauna control unit
2
Temperature sensor with excess temperature cut-out
3
Evaporator 1.0 kW or 1.5 kW
4
Heating system 3.45 kW, 4.5 kW, 6.0 kW or 7.5 kW
5
Power supply
Remove the copper bridge
*
*