Installation instructions, for professionals only
p. 10/34
WARNING!
Danger of electric shock
●
The sauna heater may only be installed and connected when the power
supply is disconnected.
4. Installation and connection
Take the following points into account when positioning and connecting the sauna
heater:
● The electrical connection may only be performed by a qualified electrician or
similarly qualified person.
●
A fully disconnecting all-pole isolating device compliant with overvoltage
category III must be fitted on site.
●
The Concept R mini combi sauna heater can be used as a wall-mounted
heater or as a free-standing heater. When mounted to the wall, check that
the heater has been firmly installed on the mounting rail before starting heater
operation. When installing the device with foot, check that the footing is firm.
4.1. Installation location and sensor position
Position the heater centrally in front of the air intake opening on the cabin wall.
Comply with the safety intervals to the cabin wall specified in
Fig. 1
.
Install the temperature sensor with overheat cut-out to the cabin wall above the
centre of the sauna heater. Maintain a distance of 15 cm to the sauna cabin roof.