![Harris FR6822+ Скачать руководство пользователя страница 80](http://html1.mh-extra.com/html/harris/fr6822/fr6822_installation-and-operation-manual_4006078080.webp)
Chapter 4
FR6822
+
QXFE Configuration, Monitoring, and Control
66
Copyright © 2008-2011, Harris Corporation
Figure 4-32
Add Trap Destination Dialog Box
2
Choose the SNMP version that the receiving device uses.
3
Enter the IP address of that trap destination.
4
Choose the port number.
The default is 162. You may need to change this depending on how your network servers
are configured. The available range is from 0 to 65535.
5
Click
Apply
.
A new line is added in the
Trap Destination IP Addresses
field.
6
Repeat steps 2 through 5 to add more rows to the dialog box.
7
Click
OK
to return to the
SNMP
tab of the
Configuration
dialog box.
Modifying a Trap Destination in CCS Navigator
To modify a trap destination, follow this procedure:
1
In the
Trap Destinations IP Addresses
list, click on the item you would like to modify.
2
Click the
Modify
button.
The
Modify Trap Destination
dialog box appears.
3
Make changes to the fields, which are described in
Addresses for SNMP Traps in CCS Navigator
on page 65, and then click
Apply
.
The selected entry in the
Trap Destination IP Addresses
field is updated.
4
Click
OK
to close the
Modify Trap Destination
dialog box.
Configuring Third-Party SNMP Software Control
Each device to be monitored and controlled via SNMP has a MIB file that defines the
controls and traps (alarms) for that device. These MIB files are available for download from
our website. There are also two general MIB files (leitch.mib and ccsAlarm.mib) that set up
a structure to help define parameters (objects) and alarms (traps).
To set up your 6800
+
ETH with optional SNMP to communicate with SNMP MIB browsing
software, follow these steps:
1
Make the required network connections between the 6800
+
ETH module(s) and your PC
with installed SNMP browser/control software.
2
Ensure that your 6800
+
ETH module is configured to send traps to the computer that
contains your MIB browsing software.
Содержание FR6822+
Страница 1: ...FR6822 Frames Installation and Operation Manual Edition E 175 100048 00...
Страница 2: ......
Страница 3: ...Edition E July 2011 FR6822 Frames Installation and Operation Manual...
Страница 8: ...Contents vi Copyright 2008 2011 Harris Corporation...
Страница 14: ...Preface xii Copyright 2008 2011 Harris Corporation...
Страница 22: ...Chapter 1 Introduction 8 Copyright 2008 2011 Harris Corporation...
Страница 40: ...Chapter 2 Installation 26 Copyright 2008 2011 Harris Corporation...
Страница 88: ...Chapter 4 FR6822 QXFE Configuration Monitoring and Control 74 Copyright 2008 2011 Harris Corporation...
Страница 92: ...Chapter 5 Power Supplies 78 Copyright 2008 2011 Harris Corporation...
Страница 100: ...Appendix A Servicing Instructions 86 Copyright 2008 2011 Harris Corporation...
Страница 105: ...Delivering the Moment Safety Instructions and Standards Selenio 6800 Series Edition D 175 100210 00...
Страница 108: ...6800 Safety Manual book Page ii Wednesday November 16 2011 4 27 PM...