Chapter 4
FR6822
+
QXFE Configuration, Monitoring, and Control
40
Copyright © 2008-2011, Harris Corporation
12
Press
Browse
to select the software upgrade package (ZIP file).
A standard
Windows File Selection
dialog box appears.
13
Choose the upgrade ZIP file on a local or network drive.
The selected file’s path name is displayed in the edit box to the left of the
Browse
button.
Note:
The extraction process of the ZIP file is handled as part of the upgrade process. You
do not need to extract the files yourself. To view the contents of the ZIP file, click
Package
Info.
14
Press
Submit Transfer
.
A dialog box appears.
15
Confirm that you want to proceed with the request.
If you have multiple modules selected, multiple transfer tasks are submitted—one per
device.
The transfer now progresses. You may minimize the
Software Upgrade
dialog box,
continue with other tasks, or switch to the
Progress
tab to view the status of the transfers.
Note:
Closing the
Software Upgrade
dialog box does not effect any transfer processes
that may be running in the background. If you try to log off or exit the CCS software while
a transfer is underway, a notification dialog box will alert you that processes are still active
and will ask if you want to terminate these processes.
16
Click on the
Log
tab and look at the
Progress
column to ensure that all files have correctly
updated.
Each upgraded module automatically reboots following an upgrade procedure.
In the unlikely event that an upgrade fails (because of such situations as network
interruptions, power failures, etc.), the upgraded module may not respond to controls and
will appear to be non-functional. Follow the procedures described in
Correcting a
Failed
Upgrading
Procedure
Firmware upgrades may fail in the event of network interruptions, power failures, or if the
wrong upgrade package was transferred to the module. These problems can be corrected
by upgrading the firmware while the module is in Boot Loader mode. The upgrade will not
work unless you put the module in Boot Loader mode.
Note:
If you have not already downloaded the most recent appropriate upgrade package
from our website or from your CD-ROM, do so now.
If the module being upgraded is a 6800
+
ETH module, see
on page 42. Otherwise, follow the steps in
on page 40, and then upgrade your module again.
Putting the Module in Boot Loader Mode
Follow these steps to put your the module in Boot Loader mode:
1
Remove the affected module from the 6800
+
frame.
Содержание FR6822+
Страница 1: ...FR6822 Frames Installation and Operation Manual Edition E 175 100048 00...
Страница 2: ......
Страница 3: ...Edition E July 2011 FR6822 Frames Installation and Operation Manual...
Страница 8: ...Contents vi Copyright 2008 2011 Harris Corporation...
Страница 14: ...Preface xii Copyright 2008 2011 Harris Corporation...
Страница 22: ...Chapter 1 Introduction 8 Copyright 2008 2011 Harris Corporation...
Страница 40: ...Chapter 2 Installation 26 Copyright 2008 2011 Harris Corporation...
Страница 88: ...Chapter 4 FR6822 QXFE Configuration Monitoring and Control 74 Copyright 2008 2011 Harris Corporation...
Страница 92: ...Chapter 5 Power Supplies 78 Copyright 2008 2011 Harris Corporation...
Страница 100: ...Appendix A Servicing Instructions 86 Copyright 2008 2011 Harris Corporation...
Страница 105: ...Delivering the Moment Safety Instructions and Standards Selenio 6800 Series Edition D 175 100210 00...
Страница 108: ...6800 Safety Manual book Page ii Wednesday November 16 2011 4 27 PM...