Figure 4-1
Discovering FR6822
+
QXFE Frames
8
In the Discovery pane, click
Save
to transfer the discovery results to the
Discovery
folder in
the
Navigation
pane.
If the frame and/or modules do not appear in the
Discovery
Controlling, and Monitoring Devices
on page 87 for troubleshooting information. Your
CCS software online Help also has extensive information on discovering devices.
Monitoring 6800
+
Modules in CCS Navigator
Once you have discovered your FR6822
+
QXFE frame in CCS Navigator and saved the results
of the discovery, the frame and modules will appear in the
Navigation
pane.
Switch Navigator to Control mode (
File
>
Operational Mode
>
Control
), and then
double-click on a module in the
Navigation
pane to open a
Control
dialog box.
Control
dialog boxes provide navigation tools to monitor read-only parameters and adjust control
parameters.
The
Diagnostics
pane, which appears across the bottom of the screen in Control mode,
provides alarm information if and when errors appear.
See Volume 1: Chapter 15 of your
CCS Navigator User Manual
for more information about
configuring and controlling 6800
+
modules using CCS software.
Using Q-SEE Compliant Modules in FR6822
+
QXFE Frames
A 6800
+
ETH module can transmit monitoring thumbnails to Navigator at up to three
frames per second for all the Q-SEE compliant modules that are installed in the host
FR6822
+
QXFE frame. In addition, Q-SEE compliant modules have enhanced alarm
functionality. See your Navigator documentation for more information.
Not all modules are Q-SEE compliant. To find out if any particular module is compliant,
consult our website. Some modules may require a firmware upgrade for Q-SEE compliance.
Extra System Requirements for Thumbnails
When displaying thumbnails, Navigator’s system requirements may exceed those listed in
the manual. For best results, your system should at least meet the following requirements:
P4 / 3 GHz, dual hyperthreading CPU with 1 GB of RAM
Содержание FR6822+
Страница 1: ...FR6822 Frames Installation and Operation Manual Edition E 175 100048 00...
Страница 2: ......
Страница 3: ...Edition E July 2011 FR6822 Frames Installation and Operation Manual...
Страница 8: ...Contents vi Copyright 2008 2011 Harris Corporation...
Страница 14: ...Preface xii Copyright 2008 2011 Harris Corporation...
Страница 22: ...Chapter 1 Introduction 8 Copyright 2008 2011 Harris Corporation...
Страница 40: ...Chapter 2 Installation 26 Copyright 2008 2011 Harris Corporation...
Страница 88: ...Chapter 4 FR6822 QXFE Configuration Monitoring and Control 74 Copyright 2008 2011 Harris Corporation...
Страница 92: ...Chapter 5 Power Supplies 78 Copyright 2008 2011 Harris Corporation...
Страница 100: ...Appendix A Servicing Instructions 86 Copyright 2008 2011 Harris Corporation...
Страница 105: ...Delivering the Moment Safety Instructions and Standards Selenio 6800 Series Edition D 175 100210 00...