2 Installation
digital
Revision C • 1/04
H
A
R
R
I
S
C
O
R
P
O
R
A T
I
O
N
2-33
SETUP
SETUP —
SETUP —
SETUP —
SETUP —
SETUP —
These eight DIP switches affect logic settings for the meters and for the entire console per
the Session Module Switch Definitions table below.
SESSION MODULE SWITCHES
C
onsole-wide
S
e
ttings
Meters
#
Switch Name
ON Function (set to operator’s left)
OFF Function (set to operator’s right)
1
Meter Display Mode
Average only
Average and peak
2
Auxiliary Meter
Cue is displayed (when both Cue
Solo is displayed (when both Cue
Display Priority
and Solo are selected)
and Solo are selected)
3
Channel On Cancels
Cue and Solo are canceled when
Cue and Solo are not affected by
Cue or Solo
channel is turned on
channel on
4
Cue Lamp Control
Cue indicators blink when Cue is on
Cue indicators are solid when Cue is on
5
Solo function latch
Solo buttons are latched (alternate action)
Solo buttons are momentary
6
Off-Line buses
All modules Post-fader, but Pre-Switch
Universal/RLS, Pre-fader and Pre-Switch *
signal source
* See page 2-25 about an additional Telco module switch that affects their Off-Line source.
7
PGM/UTL 1- 4 function BMXd-8 sequential meter source selection
Meter switching for all other frame sizes
8
Spare Switch
Session Module Switch Definitions
SESSION MODULE — EXTERNAL TIMER
These connectors reset up to three external timers (like the timer
in the PRE99-1211 Turret Clock & Timer). They operate indepen-
dently of the Session module timer buttons. The two active pins
(pins 2 and 3) momentarily short together when a reset command
is issued by turning on a module that is set to reset the timer.
Session Module, External Timer Reset —
Simplified Logic Diagram
2
3 Auto Reset Common
Auto Reset Command
Inter
nal Logic
Notes:
There are no connections to pin 1.
Opto-Isolated outputs can sink up to 60 volts or
350 mA max. current flow.
2
3 Auto Reset Common
Auto Reset Command
2
3 Auto Reset Common
Auto Reset Command
+3.3VDC
EXT TIMER 1
EXT TIMER 2
EXT TIMER 3
Auto Reset Common
Auto Reset Command
no connection
(wire insertion end view)
EXT TIMER 1, 2, 3 Connectors
3
2
1
FUNCTIONAL DESCRIPTION OF CONNECTION
Equivalent to a Normally Open (N/O) relay contact. A momentary “contact closure” of 220 ms (to the Auto Reset
Common pin) is generated each time a module is turned on that has the Timer Reset Command active (DS1-7 or
DS3-7 is set ON). Connect this pin to J4-4 on the PRE99-1211 timer.
The Common (C) relay contact for the Auto Reset Command. Tie this pin to the Timer’s logic ground pin when an
active low logic is required or tie it to the Timer’s Logic Voltage when an active high logic is required. Connect
this pin to J4-3 on the PRE99-1211 timer.
PIN NAME/NUMBER
AUTO RESET COMMAND
(pin 2)
AUTO RESET COMMON
(pin 3)
Session Module EXT TIMER Logic Signal Definitions