4
Safety test
1.
Use the wiring diagram in the manual.
2.
Plug into the socket.
3.
Press the RESET button. The indicator "ON" is highlighted.
4.
Press the "TEST" button.
The indicator "ON”
will be turned off.
5.
Press the RESET button in order to use the device. Do not use if above test fails.
Specifications
Product code:
ZVWX1017 ZVWX1023 ZVWX1033
ZVWX1042
ZVWX1052
ZVWX1057
ZVWX1062
Product type:
MONO
MONO
MONO
Vertical/MONO Vertical/MONO Vertical/TRI Vertical/TRI
COP 27°T air 24°T water
5.5
5.5
5.5
5.5
5.5
5.5
5.5
Minimum outside temperature
-10°
-10°
-10°
-10°
-10°
-10°
-10°
Heating Capacity (kW) 27° air/
27° water
7.0
12.0
14.0
19.0
23.0
23.0
28.0
Nominal power consumption (A)
5,1
7,3
9,5
13,1
16
10,5
12,4
Nominal water flow rate (m³ / h)
3 to 5
5 to 7
6 to 8
8 to 10
10 to 12
10 to 12
11 to 13
Heat exchanger
Titanium
Titanium
Titanium
Titanium
Titanium
Titanium
Titanium
Airflow (m³/h)
1800
2100
2300
3200
4500
4500
4500
KW
1.3
1.82
2.36
3.3
4.1
4.1
4.1
Connection (mm)
50
50
50
50
50
50
50
Control panel
Digital
Digital
Digital
Digital
Digital
Digital
Digital
Compressor (number)
1
1
1
1
1
1
1
Ventilators
1
1
1
1
1
1
1
dB
54
54
54
55
57
57
57
RPM ventilator
950
950
950
830
830
830
830
Weight
54
63
99
108
111
111
112
Compressor
Rotary
Rotary
Rotary
Scroll
Scroll
Scroll
Scroll
Volt
230V
230V
230V
230V
230V
380V
380V
Содержание Harmo PAC Series
Страница 14: ...14...
Страница 16: ...16 Appendix wiring diagram Model ZVWX1017 ZVWX1023...
Страница 17: ...17 Model ZVWX1033...
Страница 18: ...18 Model ZVWX1042 ZVWX1052...
Страница 19: ...19 Model ZVWX1052 ZVWX1062...