background image

 

 

 
 
Introduction

 

Read the manual carefully before you open or maintain the heat pump. The manufacturer of this product will 
not be held responsible for injuries or damage to the unit, as a result of improper installation, debugging or 
unnecessary maintenance. It is essential that the instructions of this manual are followed at all times. 
Qualified personnel must install the heat pump. 
 

 

Only a qualified installer, center, personnel or an authorized dealer, should repair the heat pump. 
 

 

Maintenance and operation must be carried out according to the recommended time and frequency, as 
mentioned in this manual. 
 

 

Use original standard spare parts only. Failure to comply with these recommendations will 

you’re your

 

warranty. 

 

 

Characteristics

 

 

Durable: the heat exchanger is made of PVC & Titanium, which can withstand prolonged exposure to 
water. 
 

 

Easy operation: the heat pump is very easy to use: turn the heat pump on and set the desired water 
temperature. 

 

 

Silent operation: the intelligent LCD display allows you to set the perfect temperature. 

 

 

Low cost: the operational cost is very low compared to the high performance of this heat pump. 

 
 

Safety instructions 

 

Place the heat pump at a safe distance. Never place the pump within a radius of 350 cm from the pool. 
 

 

The heat pump can be mounted with an RCD safety plug. 

 

 

Put the RDC plug directly and solely into an earthed socket. Never use an extension cord or similar. 

 

 

Check the voltage on the plug to the power at the socket. Only use an earthed socket. 

 

 

Always check that the safety plug is working properly to ensure safety. Never remove the safety plug. 

 

 

Place the pump and plug in a dry location. The heat pump is splash proof. 

 

 

The failure to comply with these instructions could result in serious injuries. 

 

 

Important! 

Gas: Please verify the nameplate of the heat pump which mentions the gas. In case of 

R32 gas

, measures for 

explosion risk need to be taken: It is forbidden to hold an open flame (cigarette, lighter), in the vicinity of the 
heat pump. It is forbidden to install the heat pump in the vicinity of a heat source. 

 

 

Содержание Harmo PAC Series

Страница 1: ...rted by Zwembad BVBA Industrieweg 9 3190 Boortmeerbeek Belgi www harmopool eu Swimming Pool Heat pump Instruction manual Harmo PAC series Type ZVWX1017 ZVWX1023 ZVWX1033 ZVWX1042 ZVWX1052 ZVWX1057 ZVW...

Страница 2: ...5 Distance 6 Installation of the valve 6 Installation of the pool system 7 Installation of the bypass 7 Electrical wiring 8 Start up procedure 9 Condensation 9 Guidelines 9 Water chemistry 9 Winter r...

Страница 3: ...ater temperature Silent operation the intelligent LCD display allows you to set the perfect temperature Low cost the operational cost is very low compared to the high performance of this heat pump Saf...

Страница 4: ...10 10 10 Heating Capacity kW 27 air 27 water 7 0 12 0 14 0 19 0 23 0 23 0 28 0 Nominal power consumption A 5 1 7 3 9 5 13 1 16 10 5 12 4 Nominal water flow rate m h 3 to 5 5 to 7 6 to 8 8 to 10 10 to...

Страница 5: ...ide basis en gebruik de dempende rubber om het geluid en de vibratie te elimineren Keep the unit straight up at all times When the unit has been tilted it is required to wait 24 hours before re starti...

Страница 6: ...nce between the pool water and surrounding of the pipe This increases the lifespan around 3 5 Installation of the valve The placement of the chlorinator water balance equipment and the placement of in...

Страница 7: ...set correctly your heat pump will deliver its best performance The bypass has to be built as shown below Setting the valves of the by pass Install the bypass with all 3 valves entirely open Slightly...

Страница 8: ...he heat pump together with the proper wiring characteristics The current to the heat pump should only be applied when the filter pump is running For example a relay controlled by the filter pump could...

Страница 9: ...ng and contactor chatter This time delay will automatically restart the unit approximately 3 minutes after each circuit interruption Even a brief power interruption will activate this delay and preven...

Страница 10: ...t pump 4 Turn on the electrical power to the heat pump at the main panel Owner inspection The HARMO PAC heat pumps are designed and constructed to provide long performance life when installed and oper...

Страница 11: ...shut off the unit and keep the pool pump running If the water stops running out of the base pan it is condensation water Display settings 1 Under running status press to adjust the temperature 2 Press...

Страница 12: ...tection cooling mode setting press to alter Press SET again to confirm Press M again E 40 Press SET to enter Max temp setting press to alter Press SET again to confirm Press M again F 2 Press SET to e...

Страница 13: ...able o Under parameter setting press to set data o Please note no motion on the display for 10s the LCD will display water in water out temp under running or ambient temp under standby status o Under...

Страница 14: ...14...

Страница 15: ...filter o The area around the heat pump should be dry clean and well ventilated Clean the heat exchanger regularly to maintain a good heat exchange and to save energy o Only a certified technician shou...

Страница 16: ...16 Appendix wiring diagram Model ZVWX1017 ZVWX1023...

Страница 17: ...17 Model ZVWX1033...

Страница 18: ...18 Model ZVWX1042 ZVWX1052...

Страница 19: ...19 Model ZVWX1052 ZVWX1062...

Отзывы: