6. Select 

3 Input Type

, (Options: MPEG and DVB). This also sets the respective PSI/SI tables 

for the output stream.

NOTE:  

The default option for stream type is DVB. For ATSC systems, set the stream type to MPEG.

7. To configure the multiplex output:

i

Navigate 

Root > 3 Routing and Descrambling > 1 TS (1,2,3 or 4) > 4 Output Selection

.

ii

Select one or more outputs for the received transport stream (Options: ASI 1, ASI 2, 
Socket 1, Socket 2, Socket 3 and Socket 4.) The four sockets are virtual and must be 
mapped to a physical MPEGoIP port.

iii Select 

Enable

 in each output sub-menu that you select.

NOTE:  

In this mode, stream information is not processed and output bit rate is identical to input bit 

rate.

iv Navigate 

Root > 3 Routing and Descrambling > 1 TS 1 (1,2,3 or 4) > 1 Activation

.

v

Select 

1 Enable

.

8. To select a program for descrambling:

i

Navigate 

Root > 3 Routing Descrambling > 1 TS (1,2,3 or 4) > Descrambling

.

A list displays of all input programs received.

Program name, program ID, program type and program scrambling state display.

ii

Select a program for descrambling.

iii Select CAM Selection.

iv Select CAM 1 or CAM 2 to map the program to it.

Repeat steps 5 to 8 for each multiplex that you wish to use (1, 2, 3 or 4).

9. Navigate 

Root > 2 Decoding > 1 Configuration> 2 Input Selection

.

10. Select a multiplex, 1,2, 3 or 4, for input.

11. Set the Service Selection Mode:

i

Navigate 

Root > 2 Decoding > 1 Configuration > 1 Service Selection Mode

.

ii

Select 

2 Program Selection

.

 Descrambling 

1-3-1

1 BBC, ID:4301, TV, CAS

2 CNN, ID:4302, TV, CAS

3 IBA 2 ID:4308, AUDIO, FTA

4 MI-TV, ID:8025, TV, FTA

Содержание ProView 7000

Страница 1: ...ace For detailed information on operation and configuration of the ProView 7000 platform refer to the ProView 7000 Integrated Receiver and Stream Processor User Manual Harmonic Manual Part No MAN PVR...

Страница 2: ...een Initial Set Up You need to use the ProView 7000 front panel to configure the IP parameters Configuring the IP Parameters To configure the IP parameters of a ProView 7000 1 Press Enter on the keypa...

Страница 3: ...valent processor 2 GHz or higher 1 GB of RAM 2 GB highly recommended Windows XP Windows Vista or Windows 7 operating system Installing EMS The ProView 7000 EMS is stored in the ProView 7000 for easy i...

Страница 4: ...0 EMS 1 Double click the Harmonic ProView 7000 EMS launch icon to launch EMS The EMS GUI displays 2 Click Add Device on the EMS toolbar 3 The EMS displays the ProView 7000 Device Add dialog 4 Enter a...

Страница 5: ...If the input stream is received from a satellite navigate Root 1 Reception 1 Configuration and configure the receiver parameters according to your satellite parameters 2 If you wish to use GbE output...

Страница 6: ...ocessed and output bit rate is identical to input bit rate iv Navigate Root 3 Routing and Descrambling 1 TS 1 1 2 3 or 4 1 Activation v Select 1 Enable 8 To select a program for descrambling i Navigat...

Страница 7: ...figuration 4 Descrambling 1 CAM Selection 14 Select the CAM slot Monitoring the ProView 7000 using the Front Panel How to monitor the correct operation of the ProView 7000 device Status OK When there...

Страница 8: ...Monitoring screen displays a list of all active alarm messages raised by the ProView 7000 device The information is displayed in a tabular format providing the alarm severity level the alarm brief des...

Страница 9: ...ut Port Mapping The DVB S S2 port in the Physical Input box is mapped by default to MPEG Multiplex In 1 in the Multiplex Input box You can map different ports or additional ports to Multiplex Ins 5 St...

Страница 10: ...editable properties and the section on the right provides informative status properties that cannot be edited by the EMS user v Configure the properties in the left section and click Apply 2 To map a...

Страница 11: ...utput box ii Select Properties The Program Properties dialog displays iii Mark the Descramble with checkbox iv Select a CAM slot v Click Apply 4 To map a different port or additional ports to an MPEG...

Страница 12: ...EMM in a conditional access table CAT or even an unreferenced PID i Drag the item from the Multiplex Input box and drop it into the Multiplex Decoding Output box The Cross Connect configuration dialo...

Страница 13: ...o decode a program i Drag the program name from the Multiplex Input box and drop it on the decoding channel in the Multiplex Decoding Output box The Decoder Channel Properties dialog displays ii Confi...

Страница 14: ...LEDs A list follows with the descriptions A device that is disconnected or not logged into is displayed in light gray A connected and communicating device with no alarms is displayed in full color and...

Страница 15: ...com Copyright October 2010 Harmonic Inc All rights reserved The Alarms tab displays all the alarms received by the EMS from the ProView 7000 devices Figure 1 Alarm tab To refresh the alarm list on de...

Отзывы: