  Dry  Seasoned  Wood  Only!                               

TL2.6 Woodburning Stove

Save These Instructions

3-90-08570

a. 

Creosote- formation and Need for Removal;

When  wood  is  burned  slowly,  it  produces  tar  and  other 

organic  vapors  which  combine  with  expelled  moisture 

to  form  creosote.  The  creosote  vapors  condense  in  the 

relatively  cool  chimney  flue  of  a  slow  burning  fire.  As  a 

result,  creosote  residue  accumulates  on  the  flue  lining. 

When  ignited,  this  creosote  makes  an  extremely  hot  fire. 

The chimney and chimney connector should be inspected 

at least once every two months during the heating season 

to determine if a creosote buildup has occurred. If creosote 

has accumulated, 3mm or more, it should be removed to 

reduce the risk of a chimney fire. 

if  you  experience  a  chimney  fire;

  Close  the  air  control 

and bypass damper and notify the fire department. Do NOT 

apply water to the fire, in the firebox or in the chimney. Do not 

operate the appliance until the chimney and connector have 

been inspected and approved by a chimney professional.
Do not burn any fuel other than wood, such as charcoal, 

which can cause increased carbon monoxide production or 

overfiring. Never use highly volatile substances in your stove, 

such as gasoline, which could cause an explosion.
When  solid  fuels  are  burned  completely,  they  produce 

water and carbon dioxide. However, in long slow burns, a 

substantial amount of carbon monoxide may be produced. 

If allowed to build up, carbon monoxide (which is odorless) 

can prove fatally poisonous. Proper ventilation and draft will 

prevent this from happening.  If you smell smoke, turn up 

the air control lever setting, and thoroughly ventilate your 

dwelling.  During  future  burns,  be  careful  not  to  overload 

the stove with fuel, so you will not be tempted to constantly 

operate at a low air control setting.
Other causes of poor ventilation or draft are icing, exhaust 

fans, a blocked outside air inlet, and room air starvation. If 

your stove is sluggish and you get occasional odor, check 

these possibilities and increase the air flow in your home.

When properly maintained, your stove will give you many 

years of trouble-free service. 

Contact your dealer

 to answer 

questions regarding proper operation, trouble-shooting and 

service for your appliance. Visit www.harmanstoves.com to 

find a dealer. We recommend annual service by a qualified 

service technician.

seasonal cleaning

At least once per year, the stove, venting connectors and 

chimney  should  be  thoroughly  cleaned.  If  the  areas  are 

found to have an excessive build up of ash or creosote, it 

is recommended to increase the frequency of the cleaning. 

This will extend the life of the appliance and its components. 

A vacuum specifically designed for ash is preferred, however 

a standard shop-style vacuum with a HEPA filter may also 

work just fine. 
During cleaning, caution must be taken not to damage the 

white / gray colored ceramic combustion package in the rear 

of the firebox. When using a brush in the chimney or venting 

connector, the by-pass damper should be placed in the open 

position to help prevent ash, creosote or other debris from 

falling down onto and around the combustion package. This 

also protects the top of the combustion package from tool 

or brush damage and diverts most of the removed materials 

into  the firebox for easy  clean-up  and  removal.  Once the 

venting system has been cleaned, remove the first section 

of connector pipe from the appliance flue collar. Carefully 

vacuum the ash and debris from around the sides and top 

of the combustion package. 
The shoe brick must be removed to allow vacuum access for 

cleaning the front portion of the combustion package. 
Always use caution when refueling or when vacuuming the 

firebox and combustion package. Some users have damaged 

their combustion package with vacuum cleaner tools, and 

fire pokers. 

solid  fuel  burning  space  heaters  must  be  cleaned 

regularly, as soot, ash and creosote may accumulate.

section 9 - service and Maintenance

aLWays WEaR fIRE-REsIsTaNT gLOvEs TO 

OPERaTE THE sTOvE.  THE aIR CONTROL Is HOT 

WHILE IN OPERaTION.

CAUTION

!

Содержание TL 2.6

Страница 1: ...tibles as specified Failure to comply may cause a house fire Check building codes prior to installation Installation MUST comply with local regional state and national codes and regulations Consult lo...

Страница 2: ...EE NAMEPLATE AND INSTRUCTIONS KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALSACONSIDERABLE DISTANCE AWAY FROM THE APPLIANCE Respectez scrupuleusement les instructions du constructeur pour l installat...

Страница 3: ...obile Home US only A Mobile Home Installation 21 Section 7 Appliance Set Up A Outside Air Attachment 22 B Leveling The Appliance 22 C Optional Cooking Grill 22 D Optional Blower Kit 23 E Brushed Stain...

Страница 4: ...o the frame of the mobile home and must never be installed in a room designated for sleeping The unit must have provisions for an outside air source when installed in a mobile home C Glass Specificati...

Страница 5: ...properly designed chimney to remove CO and other combustion by products from the stove Even though this stove is designed to be as safe as possible it is important that you install a CO detector This...

Страница 6: ...trouble operating the wood stove Worse yet it may be strong enough to allow smoke leakage from the appliance Installation on lower levels and in basements can be especially affected Do NOT connect th...

Страница 7: ...by removing the four bolts near each corner of the safety label The flue cover plate and the flue collar have the same 2 bolt pattern Switch the two of them by removing the nuts from their bolts Fill...

Страница 8: ...ings have been read and followed precisely 4 This Owner s Manual has been read in it s entirety 5 Floor protection requirements have been read and followed 6 The flue connector has been installed in a...

Страница 9: ...ld after July 1 1990 Section 4 Dimensions and Clearances 22 2 564mm 28 6 726mm Centered Outside Air Kit 9 29 236mm Outside Air Kit 7 28 185mm 27 47 698mm 29 48 749mm Pedestal Legs 29 7 755mm 23 9 607m...

Страница 10: ...arances To Combustibles Vertical Vent Horizontal Exit A C For clearance reduction methods refer to NFPA 211 or Local Codes A C B D B D E Location Single wall Pipe Double wall Pipe A Unit to Side Wall...

Страница 11: ...izontal Venting Configuration For clearance reduction methods refer to NFPA 211 or Local Codes Location Single wall Pipe A Unit to Side Wall 15 381 mm B Unit to Back Wall 15 381 mm C Vent Pipe to Side...

Страница 12: ...beyond the measurement of the horizontal connector Further guidelines for floor protection are as follows In the U S the floor protector must be completely under the stove and extending 16 in front of...

Страница 13: ...h is 6 inches Do not use makeshift compromises No part of the chimney connector may pass through an attic or roof The Chimney Connector Shall Not Pass Through an Attic or Roof Space Closet or Similar...

Страница 14: ...mneys extend 3 ft 0 9 m above the highest point at which they exit from the roof Then the chimney must extend 2 ft 0 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foo...

Страница 15: ...his section Since many fireplaces have exposed wooden mantels and trim pay special attention to the clearances necessary to these materials If your fireplace chimney is behind a combustible wall you m...

Страница 16: ...or Ceiling Chimney Connector Minimum air space with chimney listing Chimney support Attic radiation shield Chimney sections Chimney cap Storm collar Roof flashing Roof radiation shield SS SSS SSS SSS...

Страница 17: ...ar Concealed Space a Floor or Ceiling Minimum clearance to unprotected ceiling 15 Chimney connector sealed at thimble Flue liner with required air space Minimum of three sheet metal screws per joint o...

Страница 18: ...Similar Concealed Space a Floor or Ceiling Combustible Floor Airtight insulated clean out Flue liner with required air space Floor Protection Stainlesssteel chimney connector must extend to flue line...

Страница 19: ...Floor or Ceiling Combustible Floor UL1777 Stainless steel liner system or other approved lining system Floor Protection Follow liner manufacture s instructions on insulation and support UL1777 insulat...

Страница 20: ...otected ceiling 15 Flue liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior chimney and 2 clearance for NFPA 211 type approve...

Страница 21: ...rk arrestor 7 Use silicone to create an effective vapor barrier at the location where the chimney or other component penetrates to the exterior 8 Installation shall be in accordance with the Manufactu...

Страница 22: ...end of the metal intake flex pipe into the stub on the rear of the stove and secure it with aluminum tape This air intake will supply outside air for the secondary combustion 7 Secure the trim ring i...

Страница 23: ...m Ash lip trim and the Ash door frame To install the load door trim it is best to remove the door by lifting from the hinges lay the door down flat on it s face Drill the dimpled holes in each corner...

Страница 24: ...the handle in the open position then turn counter clockwise to engage the latch Ash Door To open the ash door lift up the handle and pull out Close the door by pushing in and pushing the handle all th...

Страница 25: ...s at the bottom front of the stove where it travels upward through channels at either side of the front door From the manifold located above the front door it is directed into the firebox as a sheet o...

Страница 26: ...Allow this start up fire to burn for a few minutes keeping the bypass damper open Add about five more pieces of wood in the 2 to 3 inch 50 80mm size range making sure that the fuel bed is all the way...

Страница 27: ...oper coal bed Open the bypass damper and continue with the process until a significant coal bed is formed Always remember to open the bypass damper when you are loading this allows the exhaust gases t...

Страница 28: ...e is sluggish and you get occasional odor check these possibilities and increase the air flow in your home When properly maintained your stove will give you many years of trouble free service Contact...

Страница 29: ...ained only through your Harman dealer To replace a broken glass first be sure to carefully remove the broken glass and any remaining shards or pieces With the door laying on a flat surface lay the gas...

Страница 30: ...with some minor disassembly you can use a vacuum and or brush to clean the blower wheel Reinstall the blower and tighten the four bolts securely 5 Chimney Connector Frequency As necessary Yearly By Q...

Страница 31: ...dburning Stove Dry Seasoned Wood Only 3 90 08570 Variable Speed Switch Power Cord Blower Thermostat Grounded to housing Black Wire White Wire 2 1 TL2 0 TL2 6 Optional Blower Kit 1 00 856002 WIRING DIA...

Страница 32: ...W Pedestal Beginning Manufacturing date sept 2011 Ending Manufacturing date active part number list on following page Wood stove 1 90 857000 1 2 3 1 4 5 6 7 8 9 10 11 14 12 15 13 16 17 18 19 20 21 22...

Страница 33: ...y Damper Shaft Retainers Hardware Set of 2 1 00 249145 y Damper Only 1 10 249107 Gasket 1 Single Ply Tape 10 Ft 1 00 88100 y 5 Firedome Plus Combustion Package 3 40 358110 y Gasket brick air Pkg of 4...

Страница 34: ...stion shoe brick 3 40 00100 y Shoe brick gasket 3 44 06951 y 24 Side brick insulation Qty 2 req 3 40 857054 y 25 Right side panel painted 2 00 857021B y 26 Heat shield mounting plate painted 2 00 8560...

Страница 35: ...de 5 Zinc Plated Hex Pkg of 50 3 30 1122 50 y Cap Screw 1 4 20 x 3 8 Grade 5 Zinc Hex Pkg of 25 3 30 1106 25 y Cap Screw 5 16 18 x 3 4 Grade 8 Plain Finish Hex Pkg of 50 3 30 1126 50 y Dowel Pin 3 16...

Страница 36: ...gs Beginning Manufacturing date sept 2011 Ending Manufacturing date active part number list on following page Wood stove 1 90 858000 1 1 2 3 7 6 5 4 8 9 10 11 12 13 14 15 17 16 18 19 20 21 22 23 24 25...

Страница 37: ...ed 3 50 00500S y 7 Damper shaft bushing plates w hardware Inner outer 1 00 856061 y 8 Damper rod weldment 1 10 856011W y 9 Left side panel painted 2 00 857019B y 10 Top Load door Lift Arm w Knob Post...

Страница 38: ...ent 1 10 856004W y 21 Air slide 1 10 856003W y 22 Shoe brick gasket 3 44 06951 y 23 Queen Ann Leg painted w Hardware Qty 4 req 1 00 7000551 y 24 Right side panel painted 2 00 857021B y 25 Heat shield...

Страница 39: ...5 Zinc Plated Hex Pkg of 50 3 30 1122 50 y Cap Screw 1 4 20 x 3 8 Grade 5 Zinc Hex Pkg of 25 3 30 1106 25 y Cap Screw 5 16 18 x 3 4 Grade 8 Plain Finish Hex Pkg of 50 3 30 1126 50 y Dowel Pin 3 16 x...

Страница 40: ...or after July 1 1990 0 8 5 grams Per Hour sMoKe 50 60 70 80 90 100 Wood heaters with higher efficiencies cost less to operate efficiency Heat outPut 11 300 to 32 700 btu use this to choose the right...

Страница 41: ...tion warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier Th...

Страница 42: ...y does not cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw...

Страница 43: ...43 Dry Seasoned Wood Only TL2 6 Woodburning Stove Save These Instructions 3 90 08570 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 44: ...e This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth prod...

Отзывы: