background image

2

Super-Magnum Coal Stoker Stove

Do Not Burn Wet Coal!

3-90-02702R4_08/12                                                       

Hearth & Home Technologies welcomes you to our tradition of excellence! By choosing a Harman appliance, 

you have become part of a long standing family committed to meeting the heating needs of consumers with the 
most distinctive, powerful and responsible home heating products available. 

The Super-Magnum has huge features in an elegant package, giving you 5000 to 100,000+ BTU when you need 

it, automatically. You need only set your desired room temperature, keep the hopper full, and the ash pan empty. 
With the Super- Magnum, you will notice even heat throughout your zone and a level of convenience you never 
thought possible. The Super-Magnum takes advantage of Harman’s 30+ years of stove design, technology and 
manufacturing. This high output stove has Super-Smart controls coupled with minimal maintenance. Output is 
managed by a microprocessor that senses the room temperature and the fire temperature with two thermistor 
probes and then determines the best feed rate for your heating demand. The platinum combination is Harman’s 
Patented Verti-Flow

TM

 Feeder system, and ESP Control which have been developed to their highest state. These 

features work together to allow amazing heat output with little regard for fuel quality.

We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance.
Thank you for choosing Harman Home Heating.

Harman Home Heating

A division of

 

Hearth & Home Technologies, Inc.

352 Mountain House Road

Halifax, PA 17032

www.harmanstoves.com

When  This  Room  Heater  Is  Not  Properly 

Installed,  a  House  Fire  May  Result.    To 

Reduce  The  Risk  Of  Fire,  Follow  The 

Installation 

Instructions. 

 

Contact 

Local  Building  Or  Fire  Officials  About 

Restrictions  And  Installation  Inspection 

Requirements In Your Area.

Floor  protection  must  be  a  non-combustible  material,  and 

must also be placed under any horizontal sections of chimney 

connector pipe, extending 2” (51mm) 

beyond the measurement of the pipe.

Pour protéger le plancher, il faut sous 

le poêle un matériau non combustible, 

qui  doit  aussi  être  placé  sous  les 

parties  horizontales  du  tuyau  de 

raccord à la cheminée et s’étendre à 

51 mm (2 po) au-delà de la mesure du 

tuyau.

A C

D

B

F

E

E

C
D

B

A

Parallel 

Installation

Inches Millimeters

Back Wall To Hopper / Entre mur arriereet l’appareil
Side Wall To Unit / Entre mur lateral et l’appareil
Back Wall To Flue Pipe / Entre  tuyau et le mur arriere
Side Wall To Flue Pipe / Entre tuyau et le mur lateral

2              51

17            432

24            610

34            864

F

E

Corner 

Installation

Inches Millimeters

Walls to Unit Body / Entre mur adjacent et l’appareil
Walls to Flue Pipe / Entre tuyau et le mur adjacent

15           381
24           610

J

H

G

Floor Protection 

Requirements

Inches Millimeters

Sides / Côtés
Front- from glass/Devant, par rapport au verre
Rear / Arrière

8             203

 12           305

18            457

Report #/ Raport # 135-S-24-6.2

Tested to / Testé à: UL1482, 

UL 391, and ULC S627-00 

Test Date: July 2009

Approved For Use in Mobile/Manufactured Homes- 

USA ONLY

This appliance is also approved for installation into a shop.

“PREVENT HOUSE FIRES”

Install and use only in accordance with manufacturer’s installation 

and operation instructions and local codes. In absence of local 

codes, installation must meet minimum requirements of NFPA 211 

in USA. Refer to manufacturer’s instructions and local codes for 

precautions required for passing chimney through a combustible 

wall or ceiling. 

WARNING FOR MANUFACTURED HOMES: (US Only) Do not 

install appliance in a sleeping room. An outside air inlet must be 

provided. The structural integrity of the manufactured home’s floor, 

walls, and ceiling must be maintained.

Refer to manufacturer’s instructions and to local codes for 

precautions required for passing chimney through a combustible 

wall or ceiling. 

Flue connector pipe must be 6” diameter, minimum 24 MSG blue 

steel. Chimney must be factory built 103HT or masonry construction.

DO NOT CONNECT THIS APPLIANCE TO A CHIMNEY FLUE 

SERVING ANOTHER APPLIANCE.

FOR USE wITH ANTHRACITE “RICE” COAL ONLY

 Do not burn 

wet coal.

DO NOT Overfire - If Heater or chimney connector glows, you 

are overfiring.

Input Rating Maximum: 7.75 lb. Fuel/hr.

Electrical Rating: 115 VAC, 60 Hz,3.1 AMPS

Route power cord away from unit. 

DANGER:

 Risk of electrical shock. Disconnect power supply before 

servicing. For further instruction, refer to owner’s manual.

Replace glass only with 5mm ceramic, available from your dealer.

Appliance must be installed with the legs attached. Do not obstruct 

airflow under the appliance.

DANGER: 

Risk of Fire or Explosion - Do not burn garbage, 

gasoline, drain oil or other flammable liquids.

WARNING: 

Risk of Fire

Do not operate with flue draft exceeding -0.080 in water 

column.

Do not operate with fuel loading or ash removal doors open.

Do not store fuel or combustibles within marked clearances.

Inspect and clean flues and chimney regularly.

Super Magnum Coal Stoker Stove

Poêle à charbon Super Magnum

Room Heater- Coal Burning

 Appareil de chauffage d’appoint au charbon

Serial No.

№ de série

CLEARANCE TO COMBUSTIBLES /

 

DISTANCES MINIMALES DE SECURITE:

Date of Manufacture / Date de fabrication:

2009  2010  2011  JAN   FEB   MAR   APR   MAY   JUN   JUL   AUG   SEP   OCT   NOV   DEC

Fabriqué par: Harman Home Heating 352 Mountain House Road, Halifax PA 17032 (É.-U.)

P.N. 3-90-02700

IGN

CAUTION: HOT wHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN AND CLOTHING AwAY. 

CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND INSTRUCTIONS. KEEP FURNISHINGS 

AND OTHER COMBUSTIBLE MATERIALS A CONSIDERABLE DISTANCE AwAY FROM THIS APPLIANCE.

ATTENTION: CHAUD LORS DU FONCTIONNEMENT.  NE TOUCHEZ PAS L’APPAREIL.GARDEZ LES 

ENFANTS ET LES VÊTEMENTS ÉLOIGNÉS. TOUT CONTACT PEUT ENTRAÎNER DES BRÛLURES DE 

LA PEAU.  RÉFÉREZ-VOUS À LA PLAQUE SIGNALÉTIQUE ET AU MODE D’EMPLOI. GARDEZ LE 

MOBILIER ET LES AUTRES MATÉRIAUX COMBUSTIBLES BIEN À L’ÉCART DE L’APPAREIL.

008

Rapport no 135-S-24-6.2

Conforme à UL 1482, UL 391 et ULC S627-00

Date d’essai: Juillet 2009

Homologué pour les maisons mobiles et préfabriquées - É.-U. SEULEMENT

Cet appareil est également homologué pour être installé dans un atelier.

«ÉVITEZ LES INCENDIES DE MAISON»

N’installez et n’utilisez cet appareil que selon le mode d’installation et le 

mode d’emploi du fabricant et les codes locaux.  En l’absence de codes 

locaux, l’installation doit au minimum être conforme aux exigences de 

la norme NFPA 211 aux É.-U.  Voir dans les recommandations du 

fabricant et dans les codes locaux les précautions quant au passage 

d’une cheminée à travers un mur ou un plafond combustible.

MISE EN GARDE POUR LES MAISONS PRÉFABRIQUÉES : (É.-U. 

seulement) N’installez pas cet appareil dans une chambre à coucher.  

Une arrivée d’air de combustion extérieur doit être prévue.  L’intégrité 

structurelle  du  plancher,  des  murs  et  du  plafond  de  la  maison 

préfabriquée doit être maintenue.

Voir dans les recommandations du fabricant et dans les codes locaux 

les précautions quant au passage d’une cheminée à travers un mur 

ou un plafond combustible.

Le tuyau de raccord à la cheminée doit être d’un diamètre de 15,25 

cm (6 po), au minimum en acier bleu 24 MSG.  La cheminée doit être 

en métal 103HT d’usine ou construite en maçonnerie.

NE RELIEZ PAS CE POÊLE À UNE CHEMINÉE QUI SERT POUR 

UN AUTRE APPAREIL.

IL NE FAUT UTILISER QUE DE L’ANTHRACITE «RICE»,

 pas du 

charbon mouillé.

Ne  chauffez  pas  TROP.    Si  l’appareil  ou  le  raccord  de  cheminée 

rougit, c’est que le feu est trop puissant.

Consommation maximale : 7,75 lb de carburant/heure

Courant alternatif de 115 V, 60 Hz, 3,1 ampères

Éloignez le cordon électrique de l’appareil.

DANGER: 

Risque de décharge électrique.  Débranchez la prise avant 

tout entretien.  Pour plus de détails, consultez le mode d’emploi.

Ne remplacez le verre que par du verre céramique de 5 mm à obtenir 

de votre détaillant.

L’appareil doit être installé avec ses pieds fixés.  N’obstruez pas le 

passage d’air sous l’appareil.

DANGER: 

Risque d’incendie ou d’explosion.  Ne brûlez pas d’ordures, 

d’essence, d’huile de vidange ni aucun autre liquide inflammable.

MISE EN GARDE:

 Risque d’incendie.

N’utilisez pas le poêle avec un conduit de cheminée dépassant -0,080 

de colonne d’eau.

N’utilisez pas le poêle lorsque les portes du foyer et du cendrier sont 

ouvertes.

Gardez le carburant et les matériaux combustibles en dehors des 

dégagements prescrits.

Inspectez et nettoyez fréquemment les conduits et la cheminée.

G

G

H

J

Содержание Super-Magnum Coal Stoker Stove

Страница 1: ...ll minimum clearances to combustibles as specified Failure to comply may cause a house fire Check building codes prior to installation Installation MUST comply with local regional state and national c...

Страница 2: ...urn wet coal DO NOT Overfire If Heater or chimney connector glows you are overfiring Input Rating Maximum 7 75 lb Fuel hr Electrical Rating 115 VAC 60 Hz 3 1 AMPS Route power cord away from unit DANGE...

Страница 3: ...Wall Pass Throughs 11 D The Chimney 12 E Draft Test Procedure 14 Section 6 Mobile Home US only A Mobile Home Installation 15 Section 7 Appliance Set Up A Outside Air Attachment 16 B Leveling The Appli...

Страница 4: ...roperly grounded to the frame of the mobile home and must never be installed in a room designated for sleeping The unit must have provisions for an outside air source when installed in a mobile home C...

Страница 5: ...likely need increased Doing this once or twice a year will not damage your stove as long as it is hot and burning Damage is caused when the hopper is left with wet coal in it while the stove is cold T...

Страница 6: ...or is located in an adjacent room or farther away from the stove you will notice higher temperatures near the appliance CAUTION Do NOT connect this unit to a chimney flue servicing another appliance D...

Страница 7: ...08 12 C Component Locations Load Door Ash Removal Door Distribution Air Filter Distribution Blower Air Grill Heat Transfer Kit Filler Plate Verti FlowTM Feeder Control Panel Heat Exchange Cleaning Rod...

Страница 8: ...rers instructions 9 The chimney meets the minimum height requirements 10 All labels and hang tags have been removed from the glass 11 All plated surfaces have been wiped clean if applicable 12 The roo...

Страница 9: ...9 Do Not Burn Wet Coal Super Magnum Coal Stoker Stove 3 90 02702R4_08 12 4Dimensions Clearances A Appliance Dimensions...

Страница 10: ...15 381 24 610 C Floor Protection Requirements J H G Floor Protection Requirements Inches Millimeters Sides Front measured from glass Rear 8 203 12 305 18 457 Floor protection must be of a non combust...

Страница 11: ...gauge chimney connector pipe The size of the connector should be 6 inch to match the size of the flue collar opening Do not use makeshift components No part of the chimney connector may pass through a...

Страница 12: ...9 m above the highest point at which they exit from the roof Then the chimney must extend 2 ft 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof...

Страница 13: ...the preferred method a breech pipe is a piece of steel pipe used the same way In Canada a breech pipe has ridges or protrusions to lock it firmly into the refractory cement In either case the chimney...

Страница 14: ...after the test with a bolt Attach the draft meter to the hole in the connector A great chimney will have draft without a fire or heat source Set the barometric damper to maintain 06 to 08 inches of w...

Страница 15: ...urer s instructions when installing in a mobile home 7 Installation shall be in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 8 The appliance must never be installed i...

Страница 16: ...ing a hole saw or reciprocating saw You ll want the hole to be just slightly larger than the metal flex pipe 4 Attach the rodent screen to one end of the flex pipe and insert it through the wall until...

Страница 17: ...w through the duct pipe D Air Filter To ensure cleanliness of the air circulated through the heat exchange the Super Magnum is equipped with a replaceable filter The filter is located under the stove...

Страница 18: ...1 To Install the air grill remove the existing painted grill Then using the same two screws and spring washers install the brushed stainless grill G Room Sensor Installation Although not required it i...

Страница 19: ...rature conditions Or Room Temp mode where the control will adjust the rate of burn to meet a specified room temperature setting Regardless of the mode selected operation is controlled by both exhaust...

Страница 20: ...and demand temperature The circuit board also has the ability to self diagnose when things are not happening as they should be Feed adjuster Sets the maximum feed rate Test Runs all motors at full sp...

Страница 21: ...ll adjust the feed rate to maintain the desired temperature setting in the room For best results be sure the room sensor is located outside of any drafty areas and not positioned on the floor or near...

Страница 22: ...ting to increase the fire size NEVER APPLY STARTING GEL TO THE STARTING MIXTURE WITHOUT THE COMBUSTION BLOWER OPERATING warning NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER...

Страница 23: ...high when stove is cold Re set restrictor using draft meter Be sure that the blower is in its mount Remove grates and clean air chamber Follow start up procedure Replace ESP Unburned or partially burn...

Страница 24: ...pending on fuel quality OR X Firebox thorough cleaning End of heating season OR X Glass When veiw of fire becomes obstructed OR X Heat exchanger Chain scraper Whenever filling the unit hopper OR X Hop...

Страница 25: ...d from the stove you can flip the carry handle up for convenience Ashes must be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible...

Страница 26: ...lass Apply the cleaner to the cloth then wipe the glass Fly ash allowed to accumulate on the glass may lead to permanent fogging or crazing of the glass Inspect the glass and sealing gasket Replace ga...

Страница 27: ...reign objects This is also a good time to vacuum any coal residue or dust from the hopper Remember to empty and clean the hopper at the end of the burn season or whenever the stove is not going to be...

Страница 28: ...nce to be sure there are no bird nests or the like D Motors and Components 1 Feed Motor Requires no lubrication Keep the motor windings free of dust Can be wiped clean or vacuumed To remove feed motor...

Страница 29: ...s the panel in the fuel hopper Remove the knob from the heat exchange scraper handle The knob is threaded onto the shaft Remove the access panel by loosening the screws With a 1 4 socket or driver rem...

Страница 30: ...OR MAX WATTS 396 3 3A 120 VOLTS A C 60 HZ ROOM SENSOR 6 AMP GLASS FUSE EXHAUST SENSING PROBE BOARD BLACK WHITE BLACK BLACK GREEN LABEL PART NO 3 90 02703 11 PIN CONNECTOR WHITE BLACK GREEN HARMAN SUPE...

Страница 31: ...list on following page 1 90 02700 1 Beginning Manufacturing Date July 2009 Ending Manufacturing Date Active 34 33 32 31 30 29 35 37 38 28 26 24 23 39 40 41 43 36 42 20 21 22 19 18 17 1 6 7 8 9 5 2 3 4...

Страница 32: ...llow Zinc Hex Head Cap Screw Pkg of 25 3 30 1119 25 Y 15 Adjuster Plate 2 00 06713D 16 1 4 20 Grade C Zinc Plated Top Lock Nut Pkg of 50 3 30 8021 50 Y 17 3 8 16 x 1 Grade 5 Zinc Plated Hex Cap Screw...

Страница 33: ...k 9 x 4 1 2 x 1 1 4 Pkg of 7 1 00 900450125 Y 35 Angle Cut Brick Set of cut brick 2 00 00688 Y 36 Side Panel Qty 2 req 2 00 02722B 37 Body Weldment 1 89 02700W 38 Duct Cover Weldment 1 10 02740W 39 Ho...

Страница 34: ...08W Y 43 5 5 16 18 Grade 5 Zinc Plated Finished Hex Nut Pkg of 100 3 30 8005 100 Y 43 6 Pillow Block 3 31 324122 Y 43 7 1 4 20 Zinc Plated Finished Hex Nut Pkg of 100 3 30 8004 100 Y 43 8 HCS 1 4 20 X...

Страница 35: ...1 2 Grade 5 Zinc Plated Hex Cap Screw Pkg of 50 3 30 1122 50 Y 44 5 Laser Cam Assembly 1 10 02764A Y 44 6 Pillow Block 3 31 324122 Y 44 7 5 16 18 Grade 5 Zinc Plated Finished Hex Nut Pkg of 100 3 30 8...

Страница 36: ...truction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlie...

Страница 37: ...t of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enamel...

Страница 38: ...38 Super Magnum Coal Stoker Stove Do Not Burn Wet Coal 3 90 02702R4_08 12 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 39: ...39 Do Not Burn Wet Coal Super Magnum Coal Stoker Stove 3 90 02702R4_08 12 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 40: ...00 Recycled Paper At Harman we build each product to a standard not a price Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harm...

Отзывы: