background image

19

Do Not Burn Wet Coal!

Super-Magnum Coal Stoker Stove

3-90-02702R4_08/12                                                       

8

  

Operating Instructions

A.  Fuel Specifications

The  Super  Magnum  is  designed  for  use  with 

Anthracite "Rice" coal Only. Anthracite is a hard coal 

which  is  mined  mostly  in  the  Eastern  United  States. 

The post-mining process involves breaking the large 

lumps of anthracite into smaller, usable sized pieces. 

In the breaking process, the coal is sifted and sorted by 

different sized screens. Rice size is basically defined 

as  the  coal  that  has  a  maximum  size  of  3/8"  and  a 

minimum size of 3/16". 

Most  coal  suppliers  wash  the  coal  and/or  wet  it  for 

delivery, to keep the dust minimized. However, the coal 

must be dry when loading it in the stove. Therefore, it 

is  highly  recommended  that  you  purchase  your  coal 

well ahead of the heating season, to allow it time to 

dry. Coal, whether in bags or in bulk, should be stored 

in a dry area.

WARNING

"NEVER USE GASOLINE, GASOLINE-TYPE LANTERN 

FUEL, KEROSENE, CHARCOAL LIGHTER FLUID, OR 

SIMILAR LIQUIDS TO START OR "FRESHEN UP " A 

FIRE IN THIS HEATER. KEEP ALL SUCH LIQUIDS WELL 

AWAY FROM THE HEATER WHILE IN USE".

B.  General Operating Information

The  Super  Magnum's  ESP  control  will  maintain  an 

output level to fit your temperature demands. There are 

two modes of operation; "Stove Temp" mode, where the 

control will maintain a specified constant temperature, 

regardless of the surrounding environment temperature 

conditions, Or  "Room Temp" mode, where the control 

will adjust the rate of burn to meet a specified room 

temperature setting. Regardless of the mode selected, 

operation is controlled by both, exhaust temperature- 

being reported by the ESP (Exhaust Sensing Probe), 

and the microprocessor circuit board.

We'll discuss these control devices and their functions 

now.

1.  ESP (Exhaust Sensing Probe)

The ESP is a tiny thermistor located in the exhaust 

stream.  The  probe  changes  it's  thermal  resistance 

based  on  minute  changes  in  temperature,  which  is 

monitored by the circuit board and used to determine 

the  need  for  changes  in  the  burn  rate  to  meet  the 

temperature demand.  

WARNING

ROUTE POWER CORD AWAY FROM THE APPLIANCE. 

DO NOT RUN THE CORD UNDER OR IN FRONT OF 

THE APPLIANCE. 

CAUTION:  Approved  for  use  with  coal  only.  The 

use  of  any  other  fuel,  except  for  the  purpose  of 

igniting  the  coal,  will  void  the  product  warranty 

and  may  cause  damage  to  the  appliance  and/or 

your home.

Freshly delivered coal is watered down to eliminate 

dust  when  loading  and  unloading.  Wet  rice  coal 

does not flow as well as damp or dry coal. We do not 

recommend burning wet coal, however, we realize if 

it's the only coal you have it is better to burn it than 

to be cold. If you must burn wet coal, the feed rate 

may need increased in order to get the same size fire.    

Doing this once or twice a year will not damage your 

stove as long as it is hot and burning.  The damage 

is caused when the hopper has wet coal in while the 

stove is not in use.  This will cause rust and corrosion 

which is not covered by your warranty.

NOTICE

Содержание Super-Magnum Coal Stoker Stove

Страница 1: ...ll minimum clearances to combustibles as specified Failure to comply may cause a house fire Check building codes prior to installation Installation MUST comply with local regional state and national c...

Страница 2: ...urn wet coal DO NOT Overfire If Heater or chimney connector glows you are overfiring Input Rating Maximum 7 75 lb Fuel hr Electrical Rating 115 VAC 60 Hz 3 1 AMPS Route power cord away from unit DANGE...

Страница 3: ...Wall Pass Throughs 11 D The Chimney 12 E Draft Test Procedure 14 Section 6 Mobile Home US only A Mobile Home Installation 15 Section 7 Appliance Set Up A Outside Air Attachment 16 B Leveling The Appli...

Страница 4: ...roperly grounded to the frame of the mobile home and must never be installed in a room designated for sleeping The unit must have provisions for an outside air source when installed in a mobile home C...

Страница 5: ...likely need increased Doing this once or twice a year will not damage your stove as long as it is hot and burning Damage is caused when the hopper is left with wet coal in it while the stove is cold T...

Страница 6: ...or is located in an adjacent room or farther away from the stove you will notice higher temperatures near the appliance CAUTION Do NOT connect this unit to a chimney flue servicing another appliance D...

Страница 7: ...08 12 C Component Locations Load Door Ash Removal Door Distribution Air Filter Distribution Blower Air Grill Heat Transfer Kit Filler Plate Verti FlowTM Feeder Control Panel Heat Exchange Cleaning Rod...

Страница 8: ...rers instructions 9 The chimney meets the minimum height requirements 10 All labels and hang tags have been removed from the glass 11 All plated surfaces have been wiped clean if applicable 12 The roo...

Страница 9: ...9 Do Not Burn Wet Coal Super Magnum Coal Stoker Stove 3 90 02702R4_08 12 4Dimensions Clearances A Appliance Dimensions...

Страница 10: ...15 381 24 610 C Floor Protection Requirements J H G Floor Protection Requirements Inches Millimeters Sides Front measured from glass Rear 8 203 12 305 18 457 Floor protection must be of a non combust...

Страница 11: ...gauge chimney connector pipe The size of the connector should be 6 inch to match the size of the flue collar opening Do not use makeshift components No part of the chimney connector may pass through a...

Страница 12: ...9 m above the highest point at which they exit from the roof Then the chimney must extend 2 ft 6 m above the highest point within a 10 ft 3 m radius Thus the 3 foot 2 foot 10 foot rule 3ft Above roof...

Страница 13: ...the preferred method a breech pipe is a piece of steel pipe used the same way In Canada a breech pipe has ridges or protrusions to lock it firmly into the refractory cement In either case the chimney...

Страница 14: ...after the test with a bolt Attach the draft meter to the hole in the connector A great chimney will have draft without a fire or heat source Set the barometric damper to maintain 06 to 08 inches of w...

Страница 15: ...urer s instructions when installing in a mobile home 7 Installation shall be in accordance with the Manufactured Home and Safety Standard HUD CFR 3280 Part 24 8 The appliance must never be installed i...

Страница 16: ...ing a hole saw or reciprocating saw You ll want the hole to be just slightly larger than the metal flex pipe 4 Attach the rodent screen to one end of the flex pipe and insert it through the wall until...

Страница 17: ...w through the duct pipe D Air Filter To ensure cleanliness of the air circulated through the heat exchange the Super Magnum is equipped with a replaceable filter The filter is located under the stove...

Страница 18: ...1 To Install the air grill remove the existing painted grill Then using the same two screws and spring washers install the brushed stainless grill G Room Sensor Installation Although not required it i...

Страница 19: ...rature conditions Or Room Temp mode where the control will adjust the rate of burn to meet a specified room temperature setting Regardless of the mode selected operation is controlled by both exhaust...

Страница 20: ...and demand temperature The circuit board also has the ability to self diagnose when things are not happening as they should be Feed adjuster Sets the maximum feed rate Test Runs all motors at full sp...

Страница 21: ...ll adjust the feed rate to maintain the desired temperature setting in the room For best results be sure the room sensor is located outside of any drafty areas and not positioned on the floor or near...

Страница 22: ...ting to increase the fire size NEVER APPLY STARTING GEL TO THE STARTING MIXTURE WITHOUT THE COMBUSTION BLOWER OPERATING warning NEVER USE GASOLINE GASOLINE TYPE LANTERN FUEL KEROSENE CHARCOAL LIGHTER...

Страница 23: ...high when stove is cold Re set restrictor using draft meter Be sure that the blower is in its mount Remove grates and clean air chamber Follow start up procedure Replace ESP Unburned or partially burn...

Страница 24: ...pending on fuel quality OR X Firebox thorough cleaning End of heating season OR X Glass When veiw of fire becomes obstructed OR X Heat exchanger Chain scraper Whenever filling the unit hopper OR X Hop...

Страница 25: ...d from the stove you can flip the carry handle up for convenience Ashes must be placed in a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible...

Страница 26: ...lass Apply the cleaner to the cloth then wipe the glass Fly ash allowed to accumulate on the glass may lead to permanent fogging or crazing of the glass Inspect the glass and sealing gasket Replace ga...

Страница 27: ...reign objects This is also a good time to vacuum any coal residue or dust from the hopper Remember to empty and clean the hopper at the end of the burn season or whenever the stove is not going to be...

Страница 28: ...nce to be sure there are no bird nests or the like D Motors and Components 1 Feed Motor Requires no lubrication Keep the motor windings free of dust Can be wiped clean or vacuumed To remove feed motor...

Страница 29: ...s the panel in the fuel hopper Remove the knob from the heat exchange scraper handle The knob is threaded onto the shaft Remove the access panel by loosening the screws With a 1 4 socket or driver rem...

Страница 30: ...OR MAX WATTS 396 3 3A 120 VOLTS A C 60 HZ ROOM SENSOR 6 AMP GLASS FUSE EXHAUST SENSING PROBE BOARD BLACK WHITE BLACK BLACK GREEN LABEL PART NO 3 90 02703 11 PIN CONNECTOR WHITE BLACK GREEN HARMAN SUPE...

Страница 31: ...list on following page 1 90 02700 1 Beginning Manufacturing Date July 2009 Ending Manufacturing Date Active 34 33 32 31 30 29 35 37 38 28 26 24 23 39 40 41 43 36 42 20 21 22 19 18 17 1 6 7 8 9 5 2 3 4...

Страница 32: ...llow Zinc Hex Head Cap Screw Pkg of 25 3 30 1119 25 Y 15 Adjuster Plate 2 00 06713D 16 1 4 20 Grade C Zinc Plated Top Lock Nut Pkg of 50 3 30 8021 50 Y 17 3 8 16 x 1 Grade 5 Zinc Plated Hex Cap Screw...

Страница 33: ...k 9 x 4 1 2 x 1 1 4 Pkg of 7 1 00 900450125 Y 35 Angle Cut Brick Set of cut brick 2 00 00688 Y 36 Side Panel Qty 2 req 2 00 02722B 37 Body Weldment 1 89 02700W 38 Duct Cover Weldment 1 10 02740W 39 Ho...

Страница 34: ...08W Y 43 5 5 16 18 Grade 5 Zinc Plated Finished Hex Nut Pkg of 100 3 30 8005 100 Y 43 6 Pillow Block 3 31 324122 Y 43 7 1 4 20 Zinc Plated Finished Hex Nut Pkg of 100 3 30 8004 100 Y 43 8 HCS 1 4 20 X...

Страница 35: ...1 2 Grade 5 Zinc Plated Hex Cap Screw Pkg of 50 3 30 1122 50 Y 44 5 Laser Cam Assembly 1 10 02764A Y 44 6 Pillow Block 3 31 324122 Y 44 7 5 16 18 Grade 5 Zinc Plated Finished Hex Nut Pkg of 100 3 30 8...

Страница 36: ...truction warranty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlie...

Страница 37: ...t of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is not covered under warranty Damage to printed plated or enamel...

Страница 38: ...38 Super Magnum Coal Stoker Stove Do Not Burn Wet Coal 3 90 02702R4_08 12 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 39: ...39 Do Not Burn Wet Coal Super Magnum Coal Stoker Stove 3 90 02702R4_08 12 Service Maintenance Log Date Of Service Performed By Description Of Service...

Страница 40: ...00 Recycled Paper At Harman we build each product to a standard not a price Signature of Boxer Your premium quality hearth product designed and assembled by the experienced and skilled members at Harm...