1
P43 Pellet Stove
The room sensor is a small temperature sensor
on the end of a 60" wire. This sensor is installed
much like a standard wall thermostat. Because it is
so small, it can be hidden along the trim of a door-
way or even up the leg of a coffee table. There is a
remote room sensor port on the rear of the unit for
easy external connection. Use standard 18- ther-
mostat wire to extend the distance to the desired
location (50' maximum). The room sensor should
be installed in the location where you want to control
the temperature.
In most installations locating the room sensor
behind the stove near the distribution fan works well
because the sensor monitors the room air being
drawn into the distribution fan.
NOTE: Distances of more than 5 feet from the
unit or in another room are not recommended. The
room sensor is essential for the P43's excellent ef-
ficiency.
NOTE:
it is recommended that the room sen-
sor be installed,
even if only installed on the rear
of the unit as a return air sensor.
Fig. 4
room Sensor installation
Fig. 5
room Sensor and rear Shield installation
rear Shields
5/16" Hex Head
Screws (3 on
each side)
5/16" Hex Head
Screws (3 on
each side)
The rear insulated shields are split in the middle for
easy removal. Each shield has (3) 5/16" hex head
screws. Two () that only need to be loosened, and
one (1) that needs to be completely removed, to
allow the shield to slide away from the unit.
nOte:
it is not recommended that the unit be operated
with the shields removed, due to the hot and
moving parts which they protect.
Room
Sensor
Port
Содержание P43
Страница 27: ...27 P43 Pellet Stove P43 Feeder...