P43 Pellet Stove

P43  AUTOMATIC  IGNITION/OPERATION

room  temperature  Mode: 

This  setting,  see  above, 

will produce a room temperature of 70 degrees with the 

distribution blower at medium speed.

The  P43  is  a  fully  automatic  stove  that  features  two 

operating modes; 

Stove temperature Mode

 and 

room 

temperature Mode

. In Stove Temperature Mode, you 

select a burn rate and the stove will remain at the same 

burn rate regardless of the room temperature. 
In the Room Temperature Mode the stove constantly 

monitors the temperature in the room and adjusts the 

size of the fire and the heat output of the stove so that the 

room is kept at a constant temperature. Room mode, in 

the AUTO position, has the added advantage of turning 

the stove off if no heat is required and turning the stove 

on again when the room temperature drops below your 

desired room temperature.  

room temperature Mode 

Most consumers use the stove in the Room Temperature 

Mode because it is the easiest and most efficient method 

of  keeping  the  room  at  a  given  temperature.    In  the 

Room Temperature  Mode,  the  Room  Sensing  Probe 

constantly monitors room temperature. As the weather 

changes outside and your home needs varying amounts 

of heat to be at a desired temperature, the stove will 

automatically  increase  fire  size  and  heat  output  so 

that a constant even temperature is maintained. If the 

weather warms up and no heat is required, the stove 

will gradually shut down. When the house cools down, 

the stove will automatically bring the room temperature 

to the precise temperature you desire.
In the Room Temperature Mode you can select either 

auto or Manual modes

 for the 

igniter,

 using the igniter 

toggle  switch.  When  the  toggle  switch  is  in  the Auto 

position, the igniter, located inside the burn pot, is ready 

to automatically light the fire when required.  When the 

toggle switch set to the Manual position the stove can 

be lit manually with either a gel or a wax type fire starter. 

(see lighting instructions on page 19.) With the igniter 

toggle switch set in the Manual position the stove will 

automatically adjust heat output, but the stove will not 

automatically shut down if no heat is required. Instead it 

will go to its lowest setting and remain there. The Manual 

position on the igniter toggle switch lets you light the 

stove manually, should the igniter fail for any reason. 

Secondly if you are using the Harman battery back up 

system, the Manual setting will prevent the stove from 

turning off and on during a power failure, which would 

drain the back up battery, and possibly cause damage 

to the back-up or the stove.
In the Room Temperature Mode, the distribution blower 

speed can be increased or decreased by adjusting the 

Room Temp/Off/Stove Temp dial between L and H.  As 

output of the stove increases, the speed of the blower 

will increase automatically to insure that more heat is 

transferred out into the room. The distribution blower 

will shut off as the room reaches the set temperature, 

this will prevent overheating of the room.

room temperature Mode

circuit  board  dipswitches: 

On the face of the circuit board, 

there is a series of 8 switches. 

These  "ON-OFF"  switches 

are  used  to  set  the  timings 

and  temperatures  for  the 

different models of stove. For 

a P43, the switches numbered 

5  and  8  should  be  on,  with 

the  rest  of  them  off. 

never 

adjuSt theSe SwitcheS 

YOurSelF,  aS  SeriOuS 

iSSueS  cOuld  develOP.

 

Also know that if there is a need 

to  replace  an  ESP  probe,a 

switch  change  may  also  be 

needed. It is strongly recommended to have a trained service 

representative make any repairs to the appliance. 

Содержание P43

Страница 1: ...DA SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOL LOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFIC...

Страница 2: ...M R ARRI RE AU PO LE 51 mm 51 mm DU PLAFOND AU DESSUS DU PO LE 457 mm 457 mm DU COIN DU PO LE AU M R DIAGONAL 229 mm 229 mm PR VENIR LES FEUX DE MAISONS OP RER SEULEMENT AVEC LA PORTE D OUVERTURE ET L...

Страница 3: ...N ACCORDANCE WITH MANUFACTURER S INSTALLATION AND OPERATING INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS INSTALLATION INSPECTION IN YOUR AREA EPA EXEMPT PER 40 CFR 60 534 M...

Страница 4: ...e should be done by a qualified service person We recom mend that the stove be inspected before use and at least annually by a qualified service person Periodic cleaning is required throughout the hea...

Страница 5: ...d the vent pipe is installed to prevent contact with hot or moving parts Firebrick Install the firebrick horizontally on the angle bracket above the burnpot Flame Guide Install the cast iron flame gui...

Страница 6: ..._____ If the second reading is more than 05 lower than the first reading check for possible restrictions or the need for outside air see page 9 For more information on the draft test procedure refer t...

Страница 7: ...st not be installed within 3 feet 90 cm above a gas meter regulator assembly when measured from the horizontal center line of the regulator 1 I The clearance to service regulator vent outlet must be a...

Страница 8: ...the stove with high temp silicone caulking Vent Pipe Pellet venting pipe known as L or PL vent is constructed of two layers with air space between the layers This air space acts as an insulator and r...

Страница 9: ...houses To install outside air use 2 3 8 I D non combus tible flex pipe There is a break away hole on the rear panel of the P43 stove which must be removed before connecting the flex pipe The pipe shou...

Страница 10: ...throughs CAUTION Keep combustible materials such as grass leaves etc at least 3 feet away from the flue outlet on the outside of the building 1 Preferred method This method provides excellent venting...

Страница 11: ...to an existing fireplace chimney This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questio...

Страница 12: ...e sure to use ap proved pellet vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using th...

Страница 13: ...learances Minimum flue vent configuration It is recommended that outside air be installed with this venting configuration to reduce smoke and creosote smell in the room in the event of power failure M...

Страница 14: ...t Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down Blinks to indicate errors listed below Indicates power to distribution blower...

Страница 15: ...oggle switch is in the Auto position the igniter located inside the burn pot is ready to automatically light the fire when required When the toggle switch set to the Manual position the stove can be l...

Страница 16: ...re Mode is if you want to watch a large fire and the room is already up to temperature The Stove Tempera ture Mode allows you to have a larger fire and a lower sound level without the distribution blo...

Страница 17: ...fferent pellets set the feed adjuster to 4 Fig 17 This is a conservative number and will probably need to be increased After you know a feed rate setting that works well use that setting Remember if y...

Страница 18: ...into the room During operation with the temperature dial set at 5 or less the distribution fan will not operate A 5 on the temperature dial and a 5 on the feed adjuster is approximately 80 output It...

Страница 19: ...ive smoke on start up 3 The firebox low pressure switch will not allow the auger motor or the igniter element to operate if the view door or the ash pan door are open 4 Adjust Feed Rate If this is you...

Страница 20: ...r Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted while in operation Fig 22 Fig 23 A simple draft test should be performed afte...

Страница 21: ...air being drawn into the distribution fan NOTE Distances of more than 25 feet from the unit or in another room are not recommended The room sensor is essential for the P43 s excellent ef ficiency NOTE...

Страница 22: ...less pellets and heat output will be greater Note Higher ash content pellets will require more frequent cleanings 1 Shut down stove and disconnect power cord to insure that all motors are stopped 2 C...

Страница 23: ...ght through into the vent pipe Fig 27 therefore the vent pipe can also be cleaned to some extent through the flue outlet 10 Reinstall blower cover and relatch 11 Slide ash pan into stove and latch the...

Страница 24: ...d male female wire connectors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the inside rear of the feed...

Страница 25: ...aner to remove all fines 4 Reinstall feed cover wing nut and rear cover panels Fig 39 Pellet Fines will build up in this area 5 16 Hex Head Screws 2 on each side 5 16 Hex Head Screws 2 on each side Th...

Страница 26: ...HAS GONE OUT 1 No pellets in hopper 2 Draft setting is too low 3 Something is restricting fuel flow 4 Feed motor or combustion blower has failed 5 Power failure or blown fuse SMOKE IS VISIBLE COMING O...

Страница 27: ...27 P43 Pellet Stove P43 Feeder...

Страница 28: ...ght 212 lbs Blower 135 cfm Feed Rate approximate 75lb to 5 5 lbs per hr Hopper Capacity 50 lbs Fuel Wood Pellets Flue Size 3 inch Outside Air Size 2 3 8 I D inch Fuse Rating 6 amp P43 Specifications 1...

Страница 29: ...Tile Grey Slate Options The decorative tile and slate measure 11 938 x 5 938 The tile slate frame is necessary to hold the tile or slate in place on the stove There are 10 decorative tile choices and...

Страница 30: ...30 P43 Pellet Stove P43 Wiring Diagram...

Страница 31: ...1 605 Control Knob Shaft 3 3 31 015 Front Door Glass 3 40 950133125 Burn Pot Gasket 1 3 44 00409 Tailpipe Gasket 3 44 06179 Wiring Diagram 3 89 06504 Control Panel Sticker 3 90 06655A Owner s Manual 3...

Страница 32: ...g acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic bric...

Отзывы: