Harman P43 Скачать руководство пользователя страница 17

17

P43 Pellet Stove

igniter Switch to"autO"(up position)

Make sure the unit is plugged into a 10 VAC, 60 

HZ electrical source. The power light should be the 

only light lit.

1. 

turn Mode Selector to "OFF".

Fill hopper

 with pellets.

1

3. 

clean burn pot 

with scraper, if necessary.

5

4.

 if starting after an empty hopper, turn Feed 

adjuster to "teSt" 

(for one 60 second cycle).

  

This will purge pellets into the auger tube and also 

allow you to check the motors for operation. 

nOte: the auger motor will not operate with 

the view door or ash pan door open.

3

5. 

turn Feed adjuster to #4.

4

6. 

Flip  the  igniter  Switch  up 

into  the  "AUTO" 

position.

7. 

turn  the  temperature  dial 

to  the  desired 

temperature.

8. 

turn Mode Selector

 to Room Temperature or 

Stove Temperature.

9. 

Fill hopper 

with pellets and 

remove ashes

 as 

required.

6

P43 autOMatic  Start  uP

helpful hints

1. Fines are small pieces of broken pellets (sawdust). Fines do not 

flow easily and often build up on the hopper funnel bottom angles. 

You can push these fines into the feeder opening and then fill the 

hopper with pellets. As the system works, they will be burned. Or 

you can clean them out before filling the hopper.

2. The "TEST" cycle will operate the feeder motor for exactly one 

minute. Turning to "TEST" again and again may purge too much 

fuel into the burn pot causing excessive smoke on start-up.

3. The firebox low pressure switch will not allow the auger motor 

or the igniter element to operate if the view door or the ash pan 

door are open.

4. Adjust Feed Rate. If this is your first fire or you are trying different 

pellets, set the feed adjuster to #4, Fig. 17. This is a conservative 

number and will probably need to be increased. After you know a 

feed rate setting that works well, use that setting. Remember, if your 

feed rate is too high you may waste fuel.

5. This is usually a weekly maintenance procedure. Cleaning the 

burn pot with the scraper with a small amount of new fuel in the 

bottom is not a problem. First, scrape the ashes off the front of the 

burn pot into the ash pan. Then, scrape the top surface of the burn 

pot downward into the base of the burn pot. When the stove is ignited 

these scrapings will be pushed out by the feeder and burned.

6. The ash pan can hold the ashes from approximately 1 ton of 

premium fuel. This means the ashes will only need to be emptied 

a few times a year.

7.  Setting  the  feed  adjuster  #  for  maximum  burn:  With  the  unit 

burning in "AUTO", turn to "Stove Mode" and put the fan on "H". 

Set the Temperature Dial to #7. Allow the unit to burn for about 30 

minutes and check ash on front of burn pot. Fig. 18. If the ash line 

is larger than 1", turn the feed adjuster from #4 to #5. Allow another 

30 minutes of burn time and check again. If , at #6 setting, a 1" or 

less ash bed is not obtainable, it is not a problem. The 1" ash bed 

is only a maximum burn rate and at most normal settings the ash 

bed will be larger.

Fig. 17

warning

"never uSe gaSOline, gaSOline-tYPe lantern 

Fuel, KerOSene, charcOal lighter Fluid, Or 

SiMilar liQuidS tO Start Or "FreShen uP " a 

Fire  in  thiS  heater.  KeeP all  Such  liQuidS 

well awaY FrOM the heater while in uSe".

warning

OnlY uSe wOOd Pellet Fuel. dO nOt burn 

garbage in StOve.

SeeHint #7.

Fig. 18

1"

Flame Guide

Starting First Fire

nOtice: be sure there is no unburned fuel 

or other combustibles in the ash pan prior 

to lighting.

Содержание P43

Страница 1: ...DA SUITABLE FOR INSTALLATION IN MOBILE HOMES IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED A HOUSE FIRE MAY RESULT FOR YOUR SAFETY FOL LOW INSTALLATION DIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFIC...

Страница 2: ...M R ARRI RE AU PO LE 51 mm 51 mm DU PLAFOND AU DESSUS DU PO LE 457 mm 457 mm DU COIN DU PO LE AU M R DIAGONAL 229 mm 229 mm PR VENIR LES FEUX DE MAISONS OP RER SEULEMENT AVEC LA PORTE D OUVERTURE ET L...

Страница 3: ...N ACCORDANCE WITH MANUFACTURER S INSTALLATION AND OPERATING INSTRUCTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS INSTALLATION INSPECTION IN YOUR AREA EPA EXEMPT PER 40 CFR 60 534 M...

Страница 4: ...e should be done by a qualified service person We recom mend that the stove be inspected before use and at least annually by a qualified service person Periodic cleaning is required throughout the hea...

Страница 5: ...d the vent pipe is installed to prevent contact with hot or moving parts Firebrick Install the firebrick horizontally on the angle bracket above the burnpot Flame Guide Install the cast iron flame gui...

Страница 6: ..._____ If the second reading is more than 05 lower than the first reading check for possible restrictions or the need for outside air see page 9 For more information on the draft test procedure refer t...

Страница 7: ...st not be installed within 3 feet 90 cm above a gas meter regulator assembly when measured from the horizontal center line of the regulator 1 I The clearance to service regulator vent outlet must be a...

Страница 8: ...the stove with high temp silicone caulking Vent Pipe Pellet venting pipe known as L or PL vent is constructed of two layers with air space between the layers This air space acts as an insulator and r...

Страница 9: ...houses To install outside air use 2 3 8 I D non combus tible flex pipe There is a break away hole on the rear panel of the P43 stove which must be removed before connecting the flex pipe The pipe shou...

Страница 10: ...throughs CAUTION Keep combustible materials such as grass leaves etc at least 3 feet away from the flue outlet on the outside of the building 1 Preferred method This method provides excellent venting...

Страница 11: ...to an existing fireplace chimney This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is questio...

Страница 12: ...e sure to use ap proved pellet vent pipe fittings Seal pipe joints with silicone or aluminum tape in addition to the sealing system used by the manufacturer Pipe size should be increased to 4 using th...

Страница 13: ...learances Minimum flue vent configuration It is recommended that outside air be installed with this venting configuration to reduce smoke and creosote smell in the room in the event of power failure M...

Страница 14: ...t Will be lit in either stove or room temp mode when pointer is not within off position band except after normal shut down Blinks to indicate errors listed below Indicates power to distribution blower...

Страница 15: ...oggle switch is in the Auto position the igniter located inside the burn pot is ready to automatically light the fire when required When the toggle switch set to the Manual position the stove can be l...

Страница 16: ...re Mode is if you want to watch a large fire and the room is already up to temperature The Stove Tempera ture Mode allows you to have a larger fire and a lower sound level without the distribution blo...

Страница 17: ...fferent pellets set the feed adjuster to 4 Fig 17 This is a conservative number and will probably need to be increased After you know a feed rate setting that works well use that setting Remember if y...

Страница 18: ...into the room During operation with the temperature dial set at 5 or less the distribution fan will not operate A 5 on the temperature dial and a 5 on the feed adjuster is approximately 80 output It...

Страница 19: ...ive smoke on start up 3 The firebox low pressure switch will not allow the auger motor or the igniter element to operate if the view door or the ash pan door are open 4 Adjust Feed Rate If this is you...

Страница 20: ...r Speed Control Low draft only set point The small straight screwdriver slot is plastic therefore the unit can be adjusted while in operation Fig 22 Fig 23 A simple draft test should be performed afte...

Страница 21: ...air being drawn into the distribution fan NOTE Distances of more than 25 feet from the unit or in another room are not recommended The room sensor is essential for the P43 s excellent ef ficiency NOTE...

Страница 22: ...less pellets and heat output will be greater Note Higher ash content pellets will require more frequent cleanings 1 Shut down stove and disconnect power cord to insure that all motors are stopped 2 C...

Страница 23: ...ght through into the vent pipe Fig 27 therefore the vent pipe can also be cleaned to some extent through the flue outlet 10 Reinstall blower cover and relatch 11 Slide ash pan into stove and latch the...

Страница 24: ...d male female wire connectors These connections between the hot leads the wires inside the burn pot and the cold leads the wires from the control board are always pulled to the inside rear of the feed...

Страница 25: ...aner to remove all fines 4 Reinstall feed cover wing nut and rear cover panels Fig 39 Pellet Fines will build up in this area 5 16 Hex Head Screws 2 on each side 5 16 Hex Head Screws 2 on each side Th...

Страница 26: ...HAS GONE OUT 1 No pellets in hopper 2 Draft setting is too low 3 Something is restricting fuel flow 4 Feed motor or combustion blower has failed 5 Power failure or blown fuse SMOKE IS VISIBLE COMING O...

Страница 27: ...27 P43 Pellet Stove P43 Feeder...

Страница 28: ...ght 212 lbs Blower 135 cfm Feed Rate approximate 75lb to 5 5 lbs per hr Hopper Capacity 50 lbs Fuel Wood Pellets Flue Size 3 inch Outside Air Size 2 3 8 I D inch Fuse Rating 6 amp P43 Specifications 1...

Страница 29: ...Tile Grey Slate Options The decorative tile and slate measure 11 938 x 5 938 The tile slate frame is necessary to hold the tile or slate in place on the stove There are 10 decorative tile choices and...

Страница 30: ...30 P43 Pellet Stove P43 Wiring Diagram...

Страница 31: ...1 605 Control Knob Shaft 3 3 31 015 Front Door Glass 3 40 950133125 Burn Pot Gasket 1 3 44 00409 Tailpipe Gasket 3 44 06179 Wiring Diagram 3 89 06504 Control Panel Sticker 3 90 06655A Owner s Manual 3...

Страница 32: ...g acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters fuses knobs glass ceramic bric...

Отзывы: