#5 Installing into an existing fireplace chimney
(Figure
4.5) w/Full Liner
This method provides excellent venting for normal operation.
This method also provides natural draft in the event of a
power failure.
In some places in the US and Canada it is required that the
vent pipe extend all the way to the top of the chimney. The
pipe or liner inside the chimney should be 4" diameter.
In this method a cap should also be installed on the chimney
to keep out rain. Be sure to use approved pellet vent pipe
fittings. Pipe size should be increased to 4" using this method.
#6 Installing into an existing chimney
(Figure 4.6) w/Full liner
This method provides excellent venting for normal operation.
This method also provides natural draft in the event of a
power failure.
In some places in the US and Canada it is required that the
vent pipe extend all the way to the top of the chimney. The
pipe or liner inside the chimney should be 4" diameter.
In this method a cap should also be installed on the chimney
to keep out rain.
Figure 4.5
Figure 4.6