#5 Installing into an existing fireplace chimney 

(Figure 

4.5) w/Full Liner

This method provides excellent venting for normal operation. 

This method also provides natural draft in the event of a 

power failure. 
In some places in the US and Canada it is required that the 

vent pipe extend all the way to the top of the chimney. The 

pipe or liner inside the chimney should be 4" diameter.
In this method a cap should also be installed on the chimney 

to keep out rain. Be sure to use approved pellet vent pipe 

fittings. Pipe size should be increased to 4" using this method.

#6 Installing into an existing chimney 

(Figure 4.6) w/Full liner

This method provides excellent venting for normal operation. 

This method also provides natural draft in the event of a 

power failure. 
In some places in the US and Canada it is required that the 

vent pipe extend all the way to the top of the chimney. The 

pipe or liner inside the chimney should be 4" diameter.
In this method a cap should also be installed on the chimney 

to keep out rain.

Figure 4.5

Figure 4.6

Содержание P43-C

Страница 1: ...y ignite clothing or other flammable materials Keep clothing furniture draperies and other flammable materials away HOT SURFACES Glass and other surfaces are hot during operation AND cool down WARNING...

Страница 2: ...n Combustible Materials Specification 5 G Combustible Materials Specification 5 H Electrical Codes 5 2 Getting Started A Design and Installation Considerations 6 B Tools and Supplies Needed 7 C Inspec...

Страница 3: ..._______________________ Electrical Section 1 120 VAC unswitched power provided to the appliance ________________________________ Check outlet with multi meter for proper voltage 115 120 VAC __________...

Страница 4: ...135PS023E 0135PS023S TYPE Pellet Fueled Supplementary For Residential Use STANDARD s ASTM E 1509 04 ULC S627 00 ASTM E 2515 11 ASTM E 2779 10 MODEL P61 C Pellet Stove LABORATORY OMNI Test Laboratories...

Страница 5: ...any component not approved by Hearth Home Technologies Install parts or components not Listed or approved Disable safety switches Improper installation adjustment alteration service or maintenance ca...

Страница 6: ...r Intakes Air Conditioner Overhang soffits porch roofs adjacent walls Landscaping vegetation Marginal Location Below peak Location NOT recommended Not the highest point of the roof Wind loading possib...

Страница 7: ...be voided by the following actions Installation and use of any damaged appliance or vent system component Modification of the appliance or vent system Installation other than as instructed by Hearth H...

Страница 8: ...tual appliance dimensions Use for reference only Figure 3 1 20 3 4 22 10 33 1 2 5 1 8 13 3 4 28 5 16 Outside Air Intake P43 C Freestanding Pellet Stove 23 1 2 10 36 1 2 5 1 8 13 3 4 29 3 8 Outside Air...

Страница 9: ...placed on or near this unit B Clearances to Combustibles When selecting a location for the appliance it is important to consider the required clearances to walls Figure 3 2 CAUTION THIS APPLIANCE MUST...

Страница 10: ...ipe Figure 3 3 J K L Floor Protector D Mobile Home Installation When installing this unit in a mobile home several requirements must be followed 1 The unit must be bolted to the floor This can be done...

Страница 11: ...vent of a power failure Do not place joints within wall pass through 2 Preferred method Figure 4 2 This method also provides excellent venting for normal operation but requires the stove to be install...

Страница 12: ...sting fireplace chimney Figure 4 4 This method provides excellent venting for normal operation This method also provides natural draft in the event of a power failure If the chimney condition is quest...

Страница 13: ...this method a cap should also be installed on the chimney to keep out rain Be sure to use approved pellet vent pipe fittings Pipe size should be increased to 4 using this method 6 Installing into an...

Страница 14: ...wall pass through Figure 4 7 Figure 4 8 Figure 4 9 Area within dotted circle represents the minimum clearance to combustible materials such as shrubbery mulch or tall grasses 12 min above ground level...

Страница 15: ...ide corner is 11 from center of pipe G The clearance to an inside corner is 12 H A vent must not be installed within 3 feet 90 cm above a gas meter regulator assembly when measured from the horizontal...

Страница 16: ...ositive static pressure Negative static pressure O Figure 4 11 Example First Floor Installation A unit is to be installed using 3 Pellet Pipe with 3 feet of horizontal pipe a Tee 10 feet of vertical p...

Страница 17: ...10 Ft 15 Ft 20 Ft 25 Ft 30 Ft 5 Ft 0 Ft 15 Ft Equivalent Vent Length EVL Maximum Horizontal Run Long runs of flex or PL vent pipe installed directly vertical from the flue stub may require more freque...

Страница 18: ...he stove especially during a power failure It may be necessary to add additional ventilation to the space in which the pellet appliance is located Consult with your local HVAC professional to determin...

Страница 19: ...windows in the home are closed Record the second draft reading _______ If the second reading is more than 05 lower than the first reading check for possible restrictions or the need for outside air Fo...

Страница 20: ...pass through fittings to go through combustible walls and ceilings Be sure to use a starting collar to attach the venting system to the stove The starting collar must be secured to the flue stub with...

Страница 21: ...pliance Modification of the appliance Installation other than as instructed by Hearth Home Technologies Installation and or use of any component part not approved by Hearth Home Technologies Operating...

Страница 22: ...t contact with hot or moving parts If needed install the 2 5 16 18 X 3 4 leveling bolts located in the hardware kit Figure 5 1 C Firebrick The P43 C Pellet Stove has a single 1 firebrick that gets ins...

Страница 23: ...stment should be done by the installer during set up because a draft meter reading is required to insure proper set up If the unit is not adjusted properly it does not cause a safety concern If the un...

Страница 24: ...HOME FLOOR WALL AND CEILING ROOF MUST BE MAINTAINED CAUTION Due to high temperatures this stove should be placed out of traffic and away from furniture and draperies Children and adults should be aler...

Страница 25: ...E PRESSURE SWITCH NO CONTACTS COMBUSTION MOTOR FEED MOTOR IGNITER ELEMENT P43 P61 P68 DISTRIBUTION BLOWER WHITE OR LT BLUE GREEN USED ON ACCENTRA ONLY DK BLUE OR BLACK ACCENTRA P35i P40i XXV DISTRIBUT...

Страница 26: ..._ 09 20 26 8390 044I 352 Mountain House Road Halifax PA 17032 www harmanstoves com Please contact your Harman dealer with any questions or concerns For the location of your nearest Harman dealer pleas...