background image

Harman Oakwood

27

Always wear gloves when 

operating the stove.

OPERATION

Do not burn wet wood!

3-90-08327R26_03/14

cooking grill

The Oakwood offers a unique stainless steel cooking grill 

that fits in the top load opening and can easily be taken in 

and out of the stove. Nothing beats the taste when cooking 

over a wood fire. 

note: always wear heat resistant gloves when opening 

the top loading door. the metal handle will be hot and 

may cause serious harm.
warming shelves

Cast  Iron  Warming  Shelves  are  available  to  accent  your 

Oakwood and are attached by steel braces.

rear heat shield

The rear heat shield will allow you to install your Oakwood 

closer to the wall. Please note there are two different shields 

based on whether the unit is rear or top vented.

bottom heat shield

The bottom heat shield allows the Oakwood to be installed on 

a combustible floor using any non-combustible floor protector 

with no specific insulating value. 

Note: A floor protector is 

always needed.
cozy screen

Your Harman® Oakwood can be burned like a fireplace with 

the optional Cozy Screen. The Cozy Screen can be used with 

either the door in place or with the cast iron door removed 

from the stove. When using the Cozy Screen, the damper 

bypass must stay in the open position or smoke spillage will 

occur. The Cozy Screen has a smoke deflector on it that is 

recommended to be used in all applications and must be 

used on all rear vent models. Note: Depending on how well 

the draft is in your installation, the smoke deflector may not 

be needed on the top vent models. 
The Cozy Screen can be used from the start of a fire or can 

be used with an existing one. When starting a fire with the 

Cozy Screen, smoke spillage may occur until it develops a 

draft strong enough to pull all smoke back into the flue.

outside air 

The Oakwood is designed to accommodate the use of outside 

air introduced directly to the stove. The opening is located at 

the back of the stove. An outside air connector plate attaches 

over  this  opening,  using  (2)  button  head  bolts(already  on 

stove).
Check  with  your  local  building  inspector  to  find  out 

requirements  determining  if  outside  air  is  needed  when 

installing the Oakwood in your area. Some signs to watch for 

that indicate a possible need for outside air: poor performance 

of other heaters or of the Oakwood, including smoke roll-out 

and odor; the disappearance of the same symptoms when 

a window is opened near the stove; and condensation on 

windows in the winter. Modern homes with tight windows and 

doors, vapor barriers, and particularly with exhaust systems 

are the most likely to require outside air.
An outside air duct less than 5' (1525 mm) long may be 3" 

[80mm] in diameter, and be made of masonry tile, 26 gauge 

(0.019)galvanized steel, or other approved noncombustible 

material;  it  should  have  a  1"  (25  mm)  clearance  to 

combustibles.  Systems  longer  than  5'  (1525  mm),  or 

containing more than two elbows, should have a 4" (100 mm) 

diameter duct to provide an adequate flow of combustion air. 

The air supply must originate outside the dwelling and be 

screened to keep out debris, birds or animals.

DO NOT INSTALL IN A SLEEPING ROOM

3" outside air duct

oPtions

Содержание Oakwood

Страница 1: ...eau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman home heating Model s Oakwood Cast Iron Wood Stove NOTICE SAVE THESE...

Страница 2: ......

Страница 3: ...eating appliance Failure to follow instructions may result in property damage bodily injury or even death Table of Contents 352 Mountain House Road Halifax PA 17032 U S A Contains updated information...

Страница 4: ...ES LIBRES AUX COMBUSTIBLES A Du mur de c t l appareil 26 660mm B Du mur arri re l appareil 28 711mm C Du tuyau de chemin e au mur de c t 38 965mm D Du tuyau de chemin e au mur arri re 32 813mm E Entre...

Страница 5: ...2 32 Grams Per Hour Emissions on Low 0 8 Grams Per Hour Log Length Recommended 21 Maximum BTU Hour Input 42 000 Heating Capacity 1 400 3 600 sq ft Outside Air Size 3 or 4 Inch Heating capacity to be u...

Страница 6: ...wood 3 90 08327R26_03 14 SPECIFICATIONS Andirons Grate Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handle Ash Door Ash Door Latch Front Load Door Latch Optional Co...

Страница 7: ...fall into the ash pan by passing a poker back and forth across the grate The andirons keep the fuel from coming into direct contact with the glass and keep hot coals and embers from spilling out while...

Страница 8: ...everal stages The initial or evaporation stage is where the moisture in the wood is driven off in the form of steam A second stage is where the volatile gases contained in the wood are released and bu...

Страница 9: ...t finger width place several 1 2 25mm 50mm split pieces of dry wood on top of the kindling followed by a few 2 3 50 mm 80 mm split pieces Lay the wood in a crossed pattern to allow maximum air flow Ig...

Страница 10: ...the bypass damper then the load door adding fuel and closing the door then the damper This depends on coal bed size load size and moisture content of fuel Removing Ashes Before reloading empty the ash...

Страница 11: ...s other than those presented here INSTALLATION Parallel versus Corner Installations A parallel installation is one in which the back and sides of the stove are parallel to the walls behind and to the...

Страница 12: ...12 Harman Oakwood 3 90 08327R26_03 14 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc 21 25...

Страница 13: ...Harman Oakwood 13 3 90 08327R26_03 14 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Страница 14: ...14 Harman Oakwood 3 90 08327R26_03 14 installation clearances See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Страница 15: ...es with hearth weight limitations The Oakwood should not be installed into a factory built fireplace unless the hearth area is designed to take the maximum weight of the stove The Oakwood loaded with...

Страница 16: ...of space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall pass through described...

Страница 17: ...e home installations a round flue either masonry or approved prefabricated of either 6 150 mm 7 180 mm or 8 200 mm may be used For square or rectangular masonry chimneys nominal sizes of 8 x 8 or 8 x...

Страница 18: ...nry fireplace may be used to install your Oakwood In addition to the requirements found in the previous paragraphs it is important to be aware that all clearances must be met including those from the...

Страница 19: ...urn up the air control lever setting and thoroughly ventilate your dwelling During future burns be careful not to overload the stove with fuel so you will not be tempted to constantly operate at a low...

Страница 20: ...ilt Chimney Roof Flashing Chimney Cap Factory Built Metal Chimney Sealed Storm Collar Finishing Collar Chimney Connector Roof Radiation Shield Cathedral Style Chimney Support Chimney Cap Storm Collar...

Страница 21: ...d air space Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Airtight insulated clean out Damper closed and sealed with non combustible material Combustibl...

Страница 22: ...ector Must Extend to Flue Liner Minimum 8 Masonry Thickness in Front of Smoke Chamber Use Damper Adapter or Seal with Non Combustible Material Floor Protection in Accordance with Solid Fuel Appliance...

Страница 23: ...s Steel Flex Liner or Other Approved Lining System in Offsets Listed Fireplace Trim Protection for Reduced Clearance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner ma...

Страница 24: ...e liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior chimney and 2 clearance for NFPA 211 type approved thimbles Airtight in...

Страница 25: ...rfaces of the controls work the controls back and forth several times during the summer or any prolonged period when you are not using your stove The Fire Chamber The inside of the fire chamber should...

Страница 26: ...ixed in place with a high temperature stove gasket cement To change a gasket first remove the worn fiberglass and clean the area with a wire brush Also clean any other surfaces that come into contact...

Страница 27: ...installation the smoke deflector may not be needed on the top vent models The Cozy Screen can be used from the start of a fire or can be used with an existing one When starting a fire with the Cozy Sc...

Страница 28: ...g Manufacturing date jan 2010 1 2 3 4 6 8 9 10 15 16 17 18 21 22 23 24 25 26 27 28 19 20 13 14 7 5 11 12 1 90 02490 1 black 1 90 02490 12 Forest green ending Manufacturing date jan 2010 1 90 02490 13...

Страница 29: ...per Elbow Painted 3 50 00500S Y 7 Cook Grill Assembly Optional 1 00 08121 8 Flue Collar 4 00 249108D 9 Top Hinge Plate Qty 2 req 2 00 249147S 10 Top 4 00 249105P Gasket 30 Ft 1 00 00888 Y 11 Top Load...

Страница 30: ...249188L 22 Ash Pan 1 10 249151 Y 23 Steel Ash Box Weldment 1 10 249144S 24 Ca Shield 2 00 249157B 25 Leg Qty 4 req 4 00 249100P Y 26 Bottom 4 00 249104D 27 Right Side Panel 4 00 249102D 28 Damper Fra...

Страница 31: ...9117A Y 32 8 Grate 2 00 249122 Y 32 9 Cast Right Inside Plate w Gasket 1 10 249118A Y 32 10 Rear Brick Retainer Pkg of 2 1 00 249135 32 11 Shoe Brick 3 40 00100 Y Gasket shoe Brick 10 Ft 1 00 11862 Y...

Страница 32: ...nty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty...

Страница 33: ...cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is no...

Страница 34: ...34 Harman Oakwood Date Of Service Performed By Description Of Service 3 90 08327R26_03 14 service maintenance log...

Страница 35: ...35 Harman Oakwood 3 90 08327R26_03 14 NOTES...

Страница 36: ...e This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth prod...

Отзывы: