Harman Oakwood

3-90-08327R26_03/14

venting

existing Masonry chimneys

If you plan on using an existing masonry chimney, have it 

thoroughly inspected and cleaned. Any faults which make 

the chimney unsafe and unusable must be repaired prior to 

use. These can include improper height, structural defects, 

blockages, inadequate clearance to combustibles, unsealed 

openings into other rooms of the house, signs of creosote or 

smoke leakage, a loose or absent clean-out door, or absence 

of a liner.

do not connect to anY air distribution 

duct or sYsteM

venting to a Masonry chimney

When connecting to a masonry chimney, several provisions 

are standard. First, whether the chimney connector is vented 

to the chimney through a thimble or a breech pipe, neither 

must pass beyond the inner surface of the chimney liner, 

and both must be firmly cemented in place with refractory 

cement.  (A  thimble  is  a  masonry  pipe  which  is  inserted 

through  the  chimney  wall,  and  is  frequently  the  preferred 

method; a breech pipe is a piece of steel pipe used the same 

way.) In Canada, a breech pipe has ridges or protrusions to 

lock it firmly into the refractory cement. In either case, the 

chimney connector vents to the chimney through the thimble 

or breech pipe.
Using a thimble, the connector slides completely inside the 

masonry to the inner edge of the flue liner, and may be easily 

removed for chimney and connector inspection. A breech 

pipe must extend at least 2" (50 mm) into the room, so the 

connector can be attached with sheet metal screws.

venting to a Masonry Fireplace chimney

In some situations, a code compliant chimney originally used 

for a masonry fireplace may be used to install your Oakwood. 

In  addition  to  the  requirements  found  in  the  previous 

paragraphs, it is important to be aware that all clearances 

must be met, including those from the chimney connector to 

combustibles — 18" (360 mm) to sides and 18" (450 mm) 

to ceiling. Do not forget to include floor protection in your 

plans. (See Clearances and Floor Protection in this section.) 

Since many fireplaces have exposed wooden mantels and 

trim, pay special attention to the clearances necessary to 

these materials.

If your fireplace chimney is behind a combustible wall, you 

must  use  an  approved  wall  pass-through  system  to  gain 

access  to  the  masonry  chimney. The  chimney  connector 

must  enter  the  chimney  at  a  place  where  it  is  lined,  and 

the fireplace must be made inoperable. For example, you 

might remove the damper, replacing it with a secure, airtight, 

noncombustible  seal,  like  a  steel  plate  (removable  for 

inspection); this also satisfies the requirement that no room air 

must be allowed to enter the chimney. Kaowool, mineral wool 

or equivalent non-combustible insulation may be installed on 

top of the plate to help minimize condensation. (Install a rain 

cap on the top of the chimney).

installing to a Prefabricated chimney

When venting your Oakwood using a prefabricated chimney, 

be  sure  to  contact  local  building  code  authorities,  and  to 

follow  the  manufacturer’s  instructions 

exactly

.  Use  only 

the manufacturer’s parts; do not use makeshift installation 

techniques. All  prefabricated  chimneys  must  be  tested  to 

either the U.S. or Canadian high-temperature standards, UL 

103 or ULC-629.

Chimney 

Connector

Clay thimble, reaching 

just to the inside of the 

chimney liner

Mechanical fasteners 

(minimum 3) but not at the 

bottom of the connector

Chimney liner 

inner edges

High-temperature 

sealant used to cement 

the clay thimble

Содержание Oakwood

Страница 1: ...eau etc to determine the need for a permit Cette guide d utilisation est disponible en francais Chez votre concessionnaire de Harman home heating Model s Oakwood Cast Iron Wood Stove NOTICE SAVE THESE...

Страница 2: ......

Страница 3: ...eating appliance Failure to follow instructions may result in property damage bodily injury or even death Table of Contents 352 Mountain House Road Halifax PA 17032 U S A Contains updated information...

Страница 4: ...ES LIBRES AUX COMBUSTIBLES A Du mur de c t l appareil 26 660mm B Du mur arri re l appareil 28 711mm C Du tuyau de chemin e au mur de c t 38 965mm D Du tuyau de chemin e au mur arri re 32 813mm E Entre...

Страница 5: ...2 32 Grams Per Hour Emissions on Low 0 8 Grams Per Hour Log Length Recommended 21 Maximum BTU Hour Input 42 000 Heating Capacity 1 400 3 600 sq ft Outside Air Size 3 or 4 Inch Heating capacity to be u...

Страница 6: ...wood 3 90 08327R26_03 14 SPECIFICATIONS Andirons Grate Top Load Opening Air Control Front Load Door Top Load Door Bypass Damper Control Handle Ash Door Ash Door Latch Front Load Door Latch Optional Co...

Страница 7: ...fall into the ash pan by passing a poker back and forth across the grate The andirons keep the fuel from coming into direct contact with the glass and keep hot coals and embers from spilling out while...

Страница 8: ...everal stages The initial or evaporation stage is where the moisture in the wood is driven off in the form of steam A second stage is where the volatile gases contained in the wood are released and bu...

Страница 9: ...t finger width place several 1 2 25mm 50mm split pieces of dry wood on top of the kindling followed by a few 2 3 50 mm 80 mm split pieces Lay the wood in a crossed pattern to allow maximum air flow Ig...

Страница 10: ...the bypass damper then the load door adding fuel and closing the door then the damper This depends on coal bed size load size and moisture content of fuel Removing Ashes Before reloading empty the ash...

Страница 11: ...s other than those presented here INSTALLATION Parallel versus Corner Installations A parallel installation is one in which the back and sides of the stove are parallel to the walls behind and to the...

Страница 12: ...12 Harman Oakwood 3 90 08327R26_03 14 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc 21 25...

Страница 13: ...Harman Oakwood 13 3 90 08327R26_03 14 INSTALLATION CLEARANCES See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Страница 14: ...14 Harman Oakwood 3 90 08327R26_03 14 installation clearances See NFPA 211 for more installation clearance reductions when using USM wall protection etc...

Страница 15: ...es with hearth weight limitations The Oakwood should not be installed into a factory built fireplace unless the hearth area is designed to take the maximum weight of the stove The Oakwood loaded with...

Страница 16: ...of space closet or other concealed space or through a floor or ceiling Whenever possible avoid passing the connector through a combustible wall if you must use an approved wall pass through described...

Страница 17: ...e home installations a round flue either masonry or approved prefabricated of either 6 150 mm 7 180 mm or 8 200 mm may be used For square or rectangular masonry chimneys nominal sizes of 8 x 8 or 8 x...

Страница 18: ...nry fireplace may be used to install your Oakwood In addition to the requirements found in the previous paragraphs it is important to be aware that all clearances must be met including those from the...

Страница 19: ...urn up the air control lever setting and thoroughly ventilate your dwelling During future burns be careful not to overload the stove with fuel so you will not be tempted to constantly operate at a low...

Страница 20: ...ilt Chimney Roof Flashing Chimney Cap Factory Built Metal Chimney Sealed Storm Collar Finishing Collar Chimney Connector Roof Radiation Shield Cathedral Style Chimney Support Chimney Cap Storm Collar...

Страница 21: ...d air space Minimum of three sheet metal screws per joint of chimney connector Mantel and trim protection Airtight insulated clean out Damper closed and sealed with non combustible material Combustibl...

Страница 22: ...ector Must Extend to Flue Liner Minimum 8 Masonry Thickness in Front of Smoke Chamber Use Damper Adapter or Seal with Non Combustible Material Floor Protection in Accordance with Solid Fuel Appliance...

Страница 23: ...s Steel Flex Liner or Other Approved Lining System in Offsets Listed Fireplace Trim Protection for Reduced Clearance UL1777 Stainless Steel Liner System or Other approved lining system Follow liner ma...

Страница 24: ...e liner with required air space Listed or approved thimble assembly 1 Clearance for exterior chimney or 2 clearance for interior chimney and 2 clearance for NFPA 211 type approved thimbles Airtight in...

Страница 25: ...rfaces of the controls work the controls back and forth several times during the summer or any prolonged period when you are not using your stove The Fire Chamber The inside of the fire chamber should...

Страница 26: ...ixed in place with a high temperature stove gasket cement To change a gasket first remove the worn fiberglass and clean the area with a wire brush Also clean any other surfaces that come into contact...

Страница 27: ...installation the smoke deflector may not be needed on the top vent models The Cozy Screen can be used from the start of a fire or can be used with an existing one When starting a fire with the Cozy Sc...

Страница 28: ...g Manufacturing date jan 2010 1 2 3 4 6 8 9 10 15 16 17 18 21 22 23 24 25 26 27 28 19 20 13 14 7 5 11 12 1 90 02490 1 black 1 90 02490 12 Forest green ending Manufacturing date jan 2010 1 90 02490 13...

Страница 29: ...per Elbow Painted 3 50 00500S Y 7 Cook Grill Assembly Optional 1 00 08121 8 Flue Collar 4 00 249108D 9 Top Hinge Plate Qty 2 req 2 00 249147S 10 Top 4 00 249105P Gasket 30 Ft 1 00 00888 Y 11 Top Load...

Страница 30: ...249188L 22 Ash Pan 1 10 249151 Y 23 Steel Ash Box Weldment 1 10 249144S 24 Ca Shield 2 00 249157B 25 Leg Qty 4 req 4 00 249100P Y 26 Bottom 4 00 249104D 27 Right Side Panel 4 00 249102D 28 Damper Fra...

Страница 31: ...9117A Y 32 8 Grate 2 00 249122 Y 32 9 Cast Right Inside Plate w Gasket 1 10 249118A Y 32 10 Rear Brick Retainer Pkg of 2 1 00 249135 32 11 Shoe Brick 3 40 00100 Y Gasket shoe Brick 10 Ft 1 00 11862 Y...

Страница 32: ...nty coverage begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent authorized HHT dealer distributor whichever occurs earlier The warranty...

Страница 33: ...cover the following Changes in surface finishes as a result of normal use As a heating appliance some changes in color of interior and exterior surface finishes may occur This is not a flaw and is no...

Страница 34: ...34 Harman Oakwood Date Of Service Performed By Description Of Service 3 90 08327R26_03 14 service maintenance log...

Страница 35: ...35 Harman Oakwood 3 90 08327R26_03 14 NOTES...

Страница 36: ...e This powerful heating appliance boasts uncompromising attention to detail and helps preserve our planet by using environmentally responsible fuels Signature of Boxer Your premium quality hearth prod...

Отзывы: