EXCEL-CPD

GAS STOVE

USER INSTRUCTIONS

57766

28

MAR 2001

Summary of Contents for EXCEL-CPD

Page 1: ...Wood multi Juel and gas stoves fires and accessories EXCEL CPD GAS STOVE USER INSTRUCTIONS 57766 28 MAR 2001 ...

Page 2: ...all times this product is concerned with high temperatures and appropriate care should ahvays be taken Bear in mind that the heat given off by the appliance may affect articles placed close to it Curtains should not be positioned above the appliance at a distance less than 12 30 centimetres from the top The appliance was not designed to be used as a dryer It is therefore not recommended that the a...

Page 3: ...and British Standards The Gas Safety Installation and Use Regulations 1994 amended 1996 The Building Regulations issued by the Department of the Environment The Building Standards Scotland Consolidation Regulations APPLIANCE TO BE INSTALLED IN ACCORDANCE TO LOCAL AND NATIONAL REGULATIONS Installation must only be undertaken by a competent person e g CORGI REGISTERED and in conjunction with the ins...

Page 4: ...rior to installation the installer should ensure that the flue is free from obstruction and ideally a chimney should be swept and subsequently smoke tested Ensure that any dampers are fixed in a permanently open position and that the chimney flue is in the professional opinion of the installer of an overall suitability for the purpose intended The Excel has no requirement for additional ventilatio...

Page 5: ...il pilot light is visibly lit this may take several attempts 2 With control knob at PILOT setting turn in an anti clockwise direction to LOW setting Important Immcdiately after lighting the stove must be left on a maximum setting for fivc minutes in order to warm up the chimney 2 Output can be increased by turning the control knob progressively in a clockwise direction until the desired level is a...

Page 6: ...identally extinguished there exists a potential tor a build up of unburned gas In this situation the FSD will automatically cut off the gas supply to the pilot and main burner This is a system that monitors the performance of the flue In the event of full or partial blockage of the chimney flue a sensor automatically interupts the gas supply to ensure flumes are not spilled into the room 57766 ...

Page 7: ... to alter the layout of the coals and it is recommended that such a practice should be avoided if at all possible Follow the instructions for coal layout in sections of the Installation Instructions book Should however any coals become broken during the cleaning process it is essential that replacements are purchased as there is an optimum number of coals for a satisfactory functioning of the stov...

Page 8: ... the guarantee are returned to us postage paid for inspection via your Yeoman stockist e That our liability is limited to the free replacement part or parts affected No claims for any other work will be considered unless agreed by Yeoman stoves management f This guarantee does not cover normal ware and tear 3 Yeoman stoves are guaranteed via the stockist tt om whom they were purchased and not dire...