Dry Seasoned Wood Only! 3-90-798 Save These Instructions
Oakleaf Woodburning stove
Chimney Breach fireplace Conversion with Combustible Wall
* floor protection in accordance with solid fuel appliance Listing
** Check with your local building codes for clearance.
Minimum Clearance from
Chimney Connector to
unprotected Ceiling
flue Liner with Required air space
Listed or approved Thimble assembly
1"Clearance for Complexity
Exterior Chimney or 2"
Clearance for Interior
Chimney and 2" Clearance
for Nfpa 211-Type
approved Thimbles
Combustible
Wall
sheetrock
airtight
insulated
Clean-out
Combustible floor
damper Closed
and sealed with
Non-Combustible
Material.
Mantel & Trim
protection
floor protection*
16"**
The Chimney Connector shall Not pass Through an attic or Roof space, Closet or similar Concealed space, a
floor or Ceiling.