Dry Seasoned Wood Only! 3-90-798 Save These Instructions
Oakleaf Woodburning stove
Oakleaf to flue fireplace Conversion (Minimum Nfpa 211 Liner Connection)
The Chimney Connector shall Not pass Through an attic or Roof space, Closet or similar Concealed space, a
floor or Ceiling.
NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in
place of the existing shield.
flue Liner with Required
air space
stainless steel Chimney
Connector Must Extend
to flue Liner
Minimum 8" Masonry
Thickness in front of
smoke Chamber
use damper adapter
or seal with Non-
Combustible Material
airtight
insulated
Clean-Out
damper plate
is Removed or
fastened in Open
position
Listed fireplace
Trim protection for
Reduced Clearance
floor protection*
Combustible floor
*floor protection in accordance with solid fuel appliance Listing