Save These Instructions 3-90-798 Dry Seasoned Wood Only!
Oakleaf Woodburning stove
B
a
B
a
B
a
CLEaRaNCE TO COMBusTIBLEs: Corner Installation,
vertical vent
CLEaRaNCE TO COMBusTIBLEs: Corner Installation
vertical vent, Horizontal Exit
a
shield Corner to Wall
14" / 356 mm
B
vent pipe to Wall
21.75" / 552 mm
a
shield Corner to Wall
14" / 356 mm
B
vent pipe to Wall
21.75" / 552 mm
Location
Location
CLEaRaNCE TO COMBusTIBLEs: Horizontal venting Configuration
Location
a
unit to side Wall
17" / 432 mm
B
unit to Back Wall
13" / 330 mm
C
vent pipe to side Wall
26.5" / 673 mm
Corner Installation
d
shield Corner to Wall
14" / 356 mm
E
Nfpa 211 specifies clearance of
18" / 457 mm
(although vent clearance may be reduced using double-wall pipe, d must be
followed)
B
a
C
E
d
*for clearance reduction methods, refer to Nfpa 211 or Local Codes
NOTICE: When using rear flue configuration, a new upper rear heat shield, #1-00-797066 must be installed in
place of the existing shield.
pipe clearance may be reduced using double wall or insulat-
ed connector pipe, provided that you adhere to the specified
clearances from the stove itself. follow pipe manufacturer's
guidelines.