DMX PowerPort 375™ User Manual
Service and maintenance
Warning! Read “Safety Information” on page 4 before servicing the DMX PowerPort 375.
Warning! Disconnect the DMX PowerPort 375 from AC mains power before servicing.
Warning! Refer any service operation not described in this manual to a qualified service
technician.
Important! Excessive dirt buildup causes overheating and will damage the product. Damage caused
by inadequate cleaning is not covered by the product warranty.
Attention ! Lisez la section "Précautions d'emploi" en page 4 avant de démarrer l'entretien du DMX
PowerPort 375.
Attention ! Déconnectez le DMX PowerPort 375 du secteur avant de commencer l'entretien.
Attention ! Référez toute opération non décrite dans ce manuel à un service technique qualifié.
Important ! Un encrassement excessif peut causer des surchauffes et endommager le produit. Les
dommages causés un nettoyage inadéquat ne sont pas couverts par la garantie du produit.
The user will need to clean the DMX PowerPort 375 periodically, and may replace fuses in the fuseholders
on the rear panel if necessary. All other service operations on the DMX PowerPort 375 must be carried out
by Martin Professional or its approved service agents.
Installation, on-site service and maintenance can be provided worldwide by the Martin Professional Global
Service organization and its approved agents, giving owners access to Martin’s expertise and product
knowledge in a partnership that will ensure the highest level of performance throughout the product’s
lifetime. Please contact your Martin supplier for details.
Fuse replacement
Warning! Replace fuses with fuses of the same type and rating only.
Attention ! Remplacez uniquement les fusibles fondus par des fusibles de même type et de même
valeur.
The DMX PowerPort 375 is protected by two 6.3 amp slow-blow fuses located in fuseholders on the rear
panel (see Figure 1 on page 8). One fuse protects the Live line and one protects the Neutral line – this setup
is necessary to ensure full protection when using a split-phase configuration on 120 V networks to obtain
208 V. If either fuse blows, the DMX PowerPort 375 and all fixtures connected to it will stop working.
If the unit stops working although it is connected to power, the overload protection may have been activated
or a fuse may have blown. If you suspect that a fuse has blown, replace the fuses as follows:
1. Disconnect the DMX PowerPort 375 from power.
2. Using a screwdriver, turn each fuseholder cap counter-clockwise to release it, then remove each fuse.
3. Replace defective fuses with fuses of the same type and rating.
4. Reinstall both fuseholder caps before reapplying power.
Cleaning
Cleaning schedules vary greatly depending on the operating environment. It is therefore impossible to
specify precise cleaning intervals for the DMX PowerPort 375. Cooling fans suck in airborne dust and smoke
particles, and in extreme cases, the product and its air filters may require cleaning after surprisingly few
hours of operation. Environmental factors that may result in a need for frequent cleaning include:
• Use of smoke or fog machines.
• High airflow rates (near air conditioning vents, for example).
• Presence of cigarette smoke.
• Airborne dust (from stage effects, building structures and fittings or the natural environment in outdoor
locations, for example).