background image

20

MAINTENANCE

Removing the Glass Front

Remove the air grill by pulling forward.
Lift the latch shown above and tilt the glass door

out at the top and lift off the hooks at the bottom.
Handle the glass with care.

Replacing the Gasket

The Conquest uses part no. 3-44-00539 fiber-

glass gasket  in the front  door. Should it  ever need
replacement, use only the proper replacement gas-
ket that is available from your Harman dealer. Re-
place the gasket as follows:

1. Lay glass door face down on a soft surface that

will not scratch the glass.

2. Remove the nuts holding the top and bottom

glass clip in place.

3. Remove glass from door and remove old gasket.
4. Install new gasket around glass.
5. Place glass back in door.
6. Reinstall glass clips and tighten the nuts.
7. Reinstall glass door by placing the slots on the

bottom of the door over the hooks on the bot-
tom of the door opening. Next, lift the latch and
push the door against the unit. Pull the spring
loaded latch front until the tab drops into the
slot on the door frame.

8.  Reinstall  air  grill.

Cleaning the Glass

The glass may be cleaned with ordinary house-

hold glass cleaner and a soft cloth or paper towel.

WARNING: Never clean the glass when it is

hot. Do not use abrasive cleaners on the glass.

A qualified service person should conduct

an annual inspection and maintenance of your
Conquest,  its  venting, and  the  installation  to
keep it running safely and efficiently. The fol-
lowing procedures should be performed only
by a qualified service person. The gas supply
should be turned off whenever a maintenance
procedure is performed.

If the glass door or side doors are  removed

for  servicing,  they  must  be  replaced  prior  to
operating the stove.

CAUTION:  Do  not  operate  this  appliance
with  the  glas s  front  removed,  cracked,  or
broken. Replacement of glass should be done
by  a  licens ed  or  qualified  service  pers on.
Never use substitute materials.

CAUTIONNER:  N’opère l’appareil avec le

v erre  enlèv e,  craque  ou  cas s e.    L e
remplacement du panneau(s) devrait être fait
par  une  pers onne  de  s ervice  qualifiá  ou
autorisá.

DO NOT STRIKE OR SLAM GLASS

Latch

Air  Grill

Gold Frame

Door

Glass

Gasket

Top
Clip

Bottom
Clip

Evaluation notes were added to the output document. To get rid of these notes, please order your copy of ePrint IV now.

Содержание Conquest Gas Stove

Страница 1: ...RYOURSAFETY FOLLOW INSTALLATIONDIRECTIONS CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATION INSPECTION REQUIREMENTS INYOUR AREA CONTACT YOUR LOCAL AUTHORITY SUCH AS MUNICIPAL...

Страница 2: ...anual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids...

Страница 3: ...earances 8 Installation 9 Venting 10 Changing To Natural Gas 14 Option Installation Thermostat 18 Remote Control 18 Glass Grill 18 Blower 19 Maintainence 20 Wiring Diagram 22 Parts 24 Trouble Shooting...

Страница 4: ...suitable location for your Conquest Gas Stove Observing required clearances to combustible ma terials the proximity to a safe chimney or venting system location and the accessibility of the gas and e...

Страница 5: ...n the logs as shown at lower left 10 Push the control knob fully down and hold Immediately push the red piezo ignitor button to light the pilot It is normal to have to push the red button several time...

Страница 6: ...to OFF unless it is pushed in slightly Do not force it FLAME HEIGHT ADJUSTMENT The flame height adjuster can be accessed by openingthe right side panel Turn the adjuster clock wise to increase flame h...

Страница 7: ...in Input Rating Btu hr 0 4500 ft 0 1375 m 14900 14100 Orifices DMS 0 4500 ft 0 1375 m 37 53 Manifold Pressure in w c kPa 3 8 95 11 0 2 75 Min Manifold Pressure in w c kPa 1 1 27 2 8 7 Min Inlet Pressu...

Страница 8: ...UCTION Unit to corner walls 2 in Unit to side wall 8 in Unit to back wall 3 in Unit to alcove ceiling 16 in Maximum alcove depth 16 in Electrical Rating 120 Volts 60 Hz 7 AMP 8 3 2 2 16 8 8 16 Alcove...

Страница 9: ...e Requirements Correct gas pressure and the use of a properly sized gas supply line are essential for the safe and efficient performance of this appliance Make sure that the plumber or gas supplier ch...

Страница 10: ...ation 36 982 1282 Snorkel Termination 14 984 1284 Horizontal Square Termination 980 1280 Vertical Termination 991 1291 Vertical Termination High Wind 950 1250 Vinyl Siding Standoff 1222D Only availabl...

Страница 11: ...cond elbow Venting with 6 5 8 x 4 Pipe A combination of one 900 elbow and two 450 elbows is allowed Subtract three feet of total horizontal pipe length for each 450 elbow used This appliance must not...

Страница 12: ...sembly when measured from the horizontalcenter line ofthe regu lator 1 I The clearance to service regulator vent outlet must be a minimum of 6 feet 1 8 m 1 J The clearance to a non mechanical air sup...

Страница 13: ...be too long with black tips and too much draft will cause flames to be short and blue To adjust the damper burn the unit on High 10 minutes or more Adjust the vent damper to a posi tion in the ranges...

Страница 14: ...orifice from the kit Natural Gas Kit Part No 1 00 09112 NG Conversion label NG Orifice 37 NG Valve Conversion Module NG Conversion Instructions This kit is only for use in the Conquest direct vent gas...

Страница 15: ...ote If no conversion is made the box for the propane box must still be marked by the installer 7 Note The higher the orifice number the smaller hole in the tip For example a number 52 orifice has a la...

Страница 16: ...s and deflector plate Ember Placement After the logs are positioned place the embers as shown above There are two types of embers supplied One is a wool like material and the other like a nugget The w...

Страница 17: ...ee threaded holes In some cases it may be helpful to remove extra paint from the treads with a 1 4 20 tap 1 Screw the set screws down until the top of the screw is about the thickness of the tile belo...

Страница 18: ...ED WIRE GAUGES Maximum Wire Length Gauge 100 14 60 16 40 18 25 20 15 22 Thermostat Remote Control Kit The button on the remote control can be used to turn the fire on and off This remote uses the ultr...

Страница 19: ...tall the other three screws 4 Route the power cord rearward between the side panel and the pedestal and plug into a 120 volt outlet 5 Open the right side panel and remove the two screws on the right s...

Страница 20: ...the tab drops into the slot on the door frame 8 Reinstall air grill Cleaning the Glass The glass may be cleaned with ordinary house hold glass cleaner and a soft cloth or paper towel W ARNING Never c...

Страница 21: ...anufacturer s instructions may provide specific suggestions or detailson vent inspection Anysections that are taken apart for the inspection must be reassembled and sealed as required Cleaning the Log...

Страница 22: ...emperature Switch Power Cord Optional Blower Wiring Diagram 120 Volt Low Voltage Wiring Diagram Caution Label all wires prior to disconnection when servicing controls Wiring errors can cause improper...

Страница 23: ...ent Gas Fireplace Heater Radiateur Ventile Model Conquest 727 WHI RATINGS NATURAL PROPANE Input Rating Btu hr 0 4500 ft 0 1375 m 29000 29000 Min Input Rating Btu hr 0 4500 ft 0 1375 m 14900 14100 Orif...

Страница 24: ...73126 Burner plate weldment 19 2 00 73127 Burner clamp 20 2 00 73141 Air guide 21 3 31 00521 Relief door springs 22 2 00 73155 Relief door 23 3 44 73133 Relief door gasket 24 1 10 73130 Right side pan...

Страница 25: ...5 3 40 09106 50 turn down LP valve 6 3 31 08792 1 2 flare fitting 7 3 44 73174 Valve gasket 8 3 90 4273 Gas label 9 2 00 73125 Sealer plate 10 3 40 09210 A Hood orifice elbow 11 3 40 09210 B 53 hood...

Страница 26: ...onnect or replace Ignitor wire Yes No Bad OK OK Bad No Yes Turn on gas valve Is gas turned on Yes OK Purge gas line to stove No Replenish supply Bad OK Replace Piezo Ignitor Check Piezo Ignitor to mak...

Страница 27: ...d Check Milivolt output of thermocouple Should be 10 or more MV Check inlet pressure Bad Adjust pilot adjustment to achieve proper flame Replace Thermocouple Bad Replace Valve Pilot does not stay lit...

Страница 28: ...position Is Pilot lit no Light pilot Yes Check Thermopile voltage at terminals marked TP on valve Should be approximately 200 mv with switch on and approximately 400 mv with switch off too low Replac...

Страница 29: ...BE USED WITH THIS CONQUEST DIRECT VENT GAS Optional Blower Label This appliance has been converted for use at an altitude of_______Feet Natural Propane Orifice Size 37 54 Manifold Pressure 3 8 WC 11...

Страница 30: ...not limited to fire lightning acts of God power failures and or surges rust corrosion and venting problems are not covered Damage and or repairs including but not limited to remote controls filters f...

Отзывы: