8
-
HARISON INDUSTRIAL DEHUMIDIFIER - USER'S MANUAL - Model: HD-100BM
Start on
1. Plug on, the unit gives off “di”.
2. Press“ON/OFF”, the running indicator lights on, and the humidity display window lights
on to display the previous set humidity. The initial setting humidity is 60% and 3 seconds
later the humidity display window light on to display current humidity.
3. Press humidity up or down key to adjust the humidity needed. If the setting humidity is
3% less than current humidity, the unit runs; if the set humidity is 3% more than current
humidity, the unit stops running.
4. When setting humidity is less than 30%, the unit dehumidify continuously, and the
humidity display window displays“CO”.
Shut off
Press “ON/OFF”when the unit is running, the unit stops running and all indicators die.
Notice:
1. When setting humidity is higher than current humidity, the unit will not run.
2. When dehumidifying, the fan motor and compressor must run at least for 3 minutes, once
the compressor start on. Forbid to restart the compressor again within 3 minutes after shut
off.
3. When working in low temperature, the unit judges the system temperature automatically
to defrost. When defrosting, the defrosting indicator lights on, the fan motor runs but
compressor shuts off automatically.
4. When pressing the memory key, the controller will record current humidity even if
power off. And the unit will run under previous mode after power supplied again.
5. The humidity display window displays the humidity from 30% to 90%.
6. Keep unplug if do not use the unit for long time.
7.When wire switch on three phase power source,zero line first,live line second or zero and
live lines together.
5. MAINTENANCE
Switch off the power source before maintenance. Pull out the plug from the socket.
Due to the accumulation of dusts, the air filter should be cleaned to avoid effecting
dehumidifying and going wrong periodically, at least once a month. If the dusts are
more in the environment, it should be cleaned every week, even every day.
Clean the air filter
When cleaning, gently tap the air filter or remove the dust with a vacuum cleaner, or you
can put the air filter in warm water (
≤
40
o
C, add a little neutral detergent ) to wash it or to
brush it, and then wash with clear water.
Attention
a. The air filter should not be exposed directly to sun of fire, to avoid deforming.
b. The air filter should be fixed before starting the dehumidifier.
Содержание HD-100BM
Страница 1: ......
Страница 11: ...Assembled in Thailand ไทย ...