supported by evidence that the failure has occurred within the warranty period, and that the 
unit has been operated within the designed parameters specified.  
 
All warranty claims must specify the unit/type number and the serial number. These details 
are printed on the unit identification plate.  
 

 
1.3. Responsibility for safety 

 
Every care has been taken in the design and manufacture of HD-100BM dehumidifier to 
ensure that they meet the safety requirements listed by federal codes. However, the 
individual operating or working on any machinery is primarily responsible for:  
 
* Personal safety, safety of other personnel, and the machinery.  
* Correct utilisation of the machinery in accordance with relevant procedures. 
 
The contents of this manual include suggested best working practices and procedures. 
These are issued for guidance only, they do not take precedence over the above stated 
individual responsibility and/or local safety regulations.  
 

 
2. PRODUCT DESCRIPTION 

 

2.1 OUTER COMPONENT IDENTIFICATION 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Handle 

Caster 

Control panel 

Room/return 
Air intake 
(nylon filter 
inside) 

Dry air out 

Leg 

Condensated 
water drain hole 

Содержание HD-100BM

Страница 1: ......

Страница 2: ...nt identification 2 2 Inner component identification and working principle a Main working principle b Dehumidifying cycle c Defrosting cycle d Safety devices function e Technical parameters f Capacity curve 3 4 5 6 7 3 Installation 3 1 Delivery and storage 3 2 Installation environment 3 3 Power sources 3 4 Installing 7 7 7 8 4 Operation 8 5 Maintenance 9 6 Troubles and Countermeasures 10 ...

Страница 3: ...hive establishment warehouses etc For preventing instruments meters communication equipment commodity reference materials from getting damp rusty mildew rot and causing damage Its most special featured function is its high mobility enabled by those unique features of internal intergrated condensed water pump rigid construction larger wheel and handle Therefore it is the only model than can be move...

Страница 4: ...they meet the safety requirements listed by federal codes However the individual operating or working on any machinery is primarily responsible for Personal safety safety of other personnel and the machinery Correct utilisation of the machinery in accordance with relevant procedures The contents of this manual include suggested best working practices and procedures These are issued for guidance on...

Страница 5: ...uch a cycle repeats time and again and refrigeration is achieved b Dehumidifying cycle The centrifugal fan makes wet air entering into the evaporator through air filter then the air is cooled down When the surface temperature of the evaporator is lower than the dew point temperature of the air the water content in the air is condensed and drained from the machine The dehumidified air is then heate...

Страница 6: ...l parameters Model HD 100BM Dehumidification Capacity Kg h 4 2 30oC 70 Rated Airflow CMH 850 Power source V 1Ph 220V 50Hz Nominal rated power kW 1 65 Rated current A 7 8 Noise level dB A 57 Overall dimensions W x D x H mm 568 x 436 x 1110 Weight Kg 64 Note Nominal working condition 27 0o C DB 21 2o C WB Low temperature working condition 5 0o C DB 2 1o C WB Notice Please use this unit under the spe...

Страница 7: ... frost and rain Inspection Remove the shipment packing and inspect unit to ensure that no damage has occurred during transportation and storage Any visible damage must be reported to nearest Harison representative 3 2 Installation Environment 1 The unit should be installed stably There should be one meter of space in front of the inflow and outflow There should be no large obstacle around it 2 The...

Страница 8: ...en connect the dehumidifier with power source and start dehumidifier as normal 4 OPERATION Control panel Instruction of keys 1 ON OFF Press ON OFF the unit runs in a circulation ON OFF ON 2 Humidity up and down Press humidity up and down for once the set humidity increase or decrease for 1 Press the key for 1 5 seconds and the setting value increase or decrease by 1 continuously with the speed 5 p...

Страница 9: ...ges the system temperature automatically to defrost When defrosting the defrosting indicator lights on the fan motor runs but compressor shuts off automatically 4 When pressing the memory key the controller will record current humidity even if power off And the unit will run under previous mode after power supplied again 5 The humidity display window displays the humidity from 30 to 90 6 Keep unpl...

Страница 10: ...c Contact dealer and repair it Water leakage Machine inclined backward Drain pipe is blocked Level the unit Remove the front panel and wipe off dirt from the pipe POWER PROTECTION light flashes The temperature sensor is open circuit or short circuit Replace the temperature sensor Machine can not defrost The temperature sensor is loosening The valve is damaged Fix the temperature sensor well Replac...

Страница 11: ...Assembled in Thailand ไทย ...