background image

D

-

EH 1700P

Air d

ehumidifier

s

Operation 

manual

Содержание DEH-1700P

Страница 1: ...D EH 1700P Air dehumidifiers Operation manual...

Страница 2: ...R www danvex fi 1...

Страница 3: ...on 3 Precautions 7 Dehumidifier description 8 Location and functions 8 Dehumidifier design 12 Control panel 13 Start up and operation 15 Specifications 20 Support and warranty 21 2 This instructions m...

Страница 4: ...ty RH below 50 and it can be disregarded at RH below 40 But at the relative humidity above 60 the rate of corrosion increases considerably This moisture damage example applies also to many other mater...

Страница 5: ...por This water percentage is expressed in g per kg of dry air absolute water content 1 m3 of dry air weighs about 1 2 kg at 20 C Depending on the temperature each kg of the air is only able to absorb...

Страница 6: ...temperature is called the dew point temperature When the air is cooled below the dew point temperature the water vapor content becomes higher than the maximum possible water vapor content Water vapor...

Страница 7: ...0kJ kg 4 18kJ 1kcal This shows that a relatively large amount of energy is released in the process of water vapor condensation If the moisture to be condensed is not generated at evaporation in the ro...

Страница 8: ...ge specified in the table 8 Please note that this unit is designed for domestic use only It is intended for household needs 9 It is not allowed to put heavy objects on the dehumidifier 10 Before trans...

Страница 9: ...to operate Unit location The unit is operated in the buildings where dry air is necessary to prevent significant financial losses for example due to mould formation The unit is mainly used for drying...

Страница 10: ...n tube Installation For optimum economical and safe unit operation the following instructions must be followed 1 The unit must be installed securely upright to ensure unhindered condensate discharge t...

Страница 11: ...y are free from foreign matters Intake filters condition should be checked as well The following instructions are to be observed 1 Extension cables should be of proper cross section 2 It is allowed to...

Страница 12: ...R www danvex fi Unit mounting is usually executed along the wall Humidifier comes standard with mounting angles to fix the humidifier to the wall as shown at Fig 1 and Fig 2 11...

Страница 13: ...R www danvex fi 12 DEHUMIFIER DESIGN 1 Dehumidified air outlet 2 Control panel 3 Air filter inside 4 Air intake 5 Humidity sensor 6 Temperature sensor 7 Collecting drain pan 8 Valve 9 Compressor...

Страница 14: ...OFF button Air heating button option Timer button Horizontal louvers ON OFF button Humidity control button Mode selection button auto dehumidification ventilation heating opt Display Auto mode Ventila...

Страница 15: ...transmitter Mode selection button Status LCD display Ventilation modes Cancel button Louvers ON OFF button Humidity control button ON OFF button Timer off button Timer on button Confirmation button H...

Страница 16: ...he optimum speed depending on the room temperature In Dehumidification mode the fan speed button is not active Temperature setting 3 Press Up or Down buttons to select the necessar temperature from 16...

Страница 17: ...fier sets the Dehumidification mode Heating mode by itself depending in the room temperature and humidity according to the table Auto mode In Auto mode the dehumidifier works only if it s equipped wit...

Страница 18: ...d in the required direction Use the SWING button on the dehumidifier panel to turn it on off To provide the better effect it s recommended to install the shutters horizontally or vertically in the deh...

Страница 19: ...R www danvex fi 18 Wiring diagram...

Страница 20: ...xation panel 15 Fan case 16 Evaporator 17 Condensate collecting pan 1 18 Condensate collecting pan 2 19 Lower trim panel 20 Mounting low panel 21 Compressor 22 Valve 23 Automatic drain system 24 Drain...

Страница 21: ...a kind of fluorinated greenhouse gases covered by the Kyoto Protocol Its total global warming potential GWP is 1975 This marking indicates that this product should not be disposed with other household...

Страница 22: ...ies the Customer a repaired or a spare part Parts repair or replacement does not result in the warranty period extension The parts and components replaced under the warranty belong to DanVex DanVex or...

Страница 23: ......

Отзывы: