The preact value is the difference between the set point and the trip point. It is used as a
compensation value when filling a vessel. If set to zero, there is no compensation.
First select the Type: Gain in Weight is used if a setpoint is a high trip limit. Loss in Weight
and deadband are used for a low trip limit, as shown in the pictures below.
Name:
Provides the option to assign a nickname to the setpoint.
Mode:
Specifies which weight source to use as the setpoint input (GROSS, NET, or
ROC).
Target:
Setpoint target weight (or rate when option is available). A setpoint ON/OFF
status change is based on this value combined with the effect of
implementing Deadband and Preact limits.
Type:
The options determine which formula to apply:
Содержание HI6800 Series