Chapter 4 - Setup
4-19
WRITEPARAM0
0x67
Write a block of
parameters:
To write a single parameter:
Step 1. Do a READPAR-
AM0 command.
Step 2. Copy the parame-
ters read to the
output.
Step 3. Change the param-
eter value
Step 4. Set the command
word.
The Metric Parameter is
processed last, which
means that all parameters
are interpreted according to
the old Metric value.
Results are saved to non-
volatile memory.
If you attempt to set a
parameter value to an
illegal value, the offset of
that parameter will appear
in the COMMAND
STATUS word.
O:0 = 0x67
O:1 = unused
O:2 = ChanActive
O:3 = Metric
O:4 = WAVERSAVER
O:5 = NumAverages
O:6 = ZeroTrackEnable
O:7 = ROCtimebase (1-1800 sec)
O:8 = AutoZeroTolerance, LSW
O:9 = AutoZeroTolerance, MSW
O:10 = MotionTolerance, LSW
O:11 = Motion Tolerance, MSW
O:12 = ZeroTolerance, LSW
O:13 = ZeroTolerance, MSW
O:14-O:15 = unused
I:0 = 0x67
I:1 = COMMAND STATUS
I:2-I:15 See READPARAM0
WRITEPARAM1
0X68
If you attempt to set a
parameter value to an
illegal value, the offset of
that parameter will appear
in the COMMAND
STATUS word.
O:0 = 0x68
O:1 = unused
O:2 = TareWeight LSW
O:3 = TareWeight MSW
O:4 = SpanWeight LSW
O:5 = SpanWeight MSW
O:6 = CalLowWeight LSW
O:7 = CalLowWeight MSW
O:8-O:15 = unused
I:0 = 0x68
I:1 = COMMAND STATUS
I:2-I:15 See READPARAM1
Command
Required Output Table Values
Written by User (PLC)
Input Table Response
From Weigh Scale
Содержание HI 1769-2WS
Страница 14: ...HI 1769 WS HI 1769 2WS WEIGH SCALE MODULE 1 6 ...
Страница 27: ...Chapter 3 Installation 3 9 FIG 3 7 RAIL FASTENERS IN THE CLOSED POSITION ...
Страница 60: ...HI 1769 WS HI 1769 2WS WEIGH SCALE MODULE 4 26 ...
Страница 74: ...HI 1769 WS HI 1769 2WS MANUAL 6 8 ...
Страница 82: ...HI 1769 WS HI 1769 2WS MANUAL Weighing System Tests 1 4 wrist strap grounding device 3 2 ...