TESTRESULTS
0x6C
Report the results of a previous
INTEGRATED
TECHNICIAN test. No new
test is performed
O:0-0x6C
O:1-15 (unused)
I:0x6C
I:1 = return to zero test result,
bit coded:
• Bits set to 1 indicate non-
return to zero.
• Bit 0 = combined weight
• Bits 1-4 (JBOX only)
indicate non-return to
zero on a individual
JBOX sensor.
I:2-15 are all INTEGER
values.
• Millivolt/volt readings
have 4 decimal places.
• Load Cell resistance has
zero decimal places.
• Sense Volts has 2 decimal
places.
I:2 = millivolts/volt,
combined, LSW
I:3 = millivolts/volt
combined, MSW
I:4 = millivolts/volt, load
sensor #1, LSW
I:5 = millivolts/volt, load
sensor #1, MSW
I:6 = millivolts/volt, load
sensor #2, LSW
I:7 = millivolts/volt, load
sensor #2, MSW
I:8 = millivolts/volt, load
sensor #3, LSW
I:9 = millivolts/volt, load
sensor #3, MSW
I:10 = millivolts/volt, load
sensor #4, LSW
I:11 = millivolts/volt, load
sensor #4, MSW
I:12 = Sense Volts, LSW
I:13 = Sense Volts, MSW
I:14 = Load cell input
resistance, as determined
from C2 at last calibration,
LSW
I:15 = Load cell input
resistance, MSW