5 - Operation
52
TurboFiller rinsing
Rinsing the TurboFiller and chemical containers are done as follows:
Cleaning empty containers - TurboFiller lid is open
1.
Put container over the rotating flushing nozzle in the middle of the
TurboFiller so that the nozzle is inside the container.
2.
Simultaneously press the Chemical Container Cleaning lever and
the TurboFiller suction valve. This rinses the chemical container
with the flushing nozzle while the rinsing liquid is emptied out of
the TurboFiller.
TurboFiller rinsing - TurboFiller lid is closed
1.
Close TurboFiller lid.
2.
Turn the suction SmartValve towards “Rinsing tank” or “External Filling Device” if clean water is available here.
3.
Simultaneously press the Chemical Container Cleaning lever and the TurboFiller suction valve. This rinses the hopper
with the flushing nozzle while the rinsing liquid is emptied out of the TurboFiller.
4.
Rinse the hopper for 30-40 seconds.
5.
Open the lid to inspect if the TurboFiller is empty. If not, close the lid again and press the TurboFiller suction valve until
the TurboFiller is empty.
6.
After the last flushing the TurboFiller suction valve must be open for at least 20 seconds after the rinse water is no
longer visible in the hopper in order to completely empty the transfer hoses into the main tank.
μ
ATTENTION! The TurboFiller needs to be cleaned thoroughly after finishing spraying again to be sure it is clean before
spraying other crops that may be sensitive to the chemicals just used. See section “Cleaning” on page 55 for details.
Agitation before resuming a spray job
If a spray job has been interrupted for a while, severe sedimentation may
occur depending on the chemicals being used. Before resuming the
spray job, it might be necessary to agitate sediment material.
1.
Turn the handle at the suction valve towards “Suction from main
tank”. Turn the pressure valve to and turn the Agitation valve
towards “Agitation”. Other valves closed.
2.
Engage the pump and set P.T.O. speed at 540 r/min.
3.
Agitation has started and should be continued for at least 10
minutes.
The spray job can now be resumed. Turn pressure valve towards
“Spraying” and start spraying.
Содержание RANGER EAGLE
Страница 8: ...1 EC Declaration 8 ...
Страница 12: ...2 Safety notes 12 ...
Страница 26: ...3 Description 26 ...
Страница 40: ...4 Sprayer setup 40 ...
Страница 60: ...5 Operation 60 ...
Страница 62: ...6 Maintenance 62 Trailer lubrication oiling plan P T O lubrication oiling plan Serie 100 type P T O shaft C 50 ...
Страница 84: ...6 Maintenance 84 ...
Страница 95: ...8 Technical specifications 95 Charts Boom hydraulic Z Boom hydraulic Y ...
Страница 96: ...8 Technical specifications 96 ...
Страница 100: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...