5 - Operation
48
Filling liquid chemicals by HARDI TurboFiller (optional)
1.
Fill the main tank at least 1/3 with water (unless otherwise stated
on the chemical container label).
2.
Turn the handle of the suction valve towards “suction from Main
tank”. Turn pressure valve to closed position. Close the
AgitationValve.
÷
NOTE! If filling water from an external tank, this can be continued
while doing the next steps.
3.
Engage the pump and set P.T.O. speed at 540 r/min or 1000 r/min
(depending on pump model).
4.
Open TurboFiller lid. Measure the correct quantity of chemical and
fill it into the hopper.
€
DANGER! Always wear face shield and other appropriate personal
safety equipment when filling chemicals.
μ
ATTENTION! The scale in the hopper can only be used if the sprayer is parked on level ground! It is recommended to
use a measuring jug for best accuracy.
5.
Engage the hopper transfer device by opening the TurboFiller suction valve transfer chemicals to the main tank. The
TurboFiller suction valve must be open for at least 20 seconds after the chemical is no longer visible in the hopper in
order to completely empty the transfer hoses into the main tank.
€
DANGER! If the TurboFiller and the transfer hoses are not completely emptied there are risk of chemicals being
siphoned out of the main tank!
6.
If the chemical container is empty, it can be rinsed by the Chemical Container Cleaning device. Place the container
over the multi-hole nozzle and push the container cleaning.
€
DANGER! In order to avoid spray liquid hitting the operator, do not press lever unless the multi-hole nozzle is covered
by a container as spray liquid may otherwise hit the operator!
μ
ATTENTION! Rinsing device uses spray liquid to rinse containers for concentrated chemicals. Always rinse the
chemical containers with clean water several times until they are clean before disposal.
7.
Flush the TurboFiller with clean water from the Rinsing tank. The TurboFiller suction valve must be open for at least 20
seconds after the rinse water is no longer visible in the hopper in order to completely empty the transfer hoses into
the main tank.
μ
ATTENTION! If not flushed with clean water, the hopper rinsing device uses spray liquid for rinsing the hopper!
Cleaning the TurboFiller must always be done when the spray job is ended and together with the entire sprayer - a
cleaning after the last filling and before spraying the last tankful does not ensure a clean TurboFiller!
Содержание RANGER EAGLE
Страница 8: ...1 EC Declaration 8 ...
Страница 12: ...2 Safety notes 12 ...
Страница 26: ...3 Description 26 ...
Страница 40: ...4 Sprayer setup 40 ...
Страница 60: ...5 Operation 60 ...
Страница 62: ...6 Maintenance 62 Trailer lubrication oiling plan P T O lubrication oiling plan Serie 100 type P T O shaft C 50 ...
Страница 84: ...6 Maintenance 84 ...
Страница 95: ...8 Technical specifications 95 Charts Boom hydraulic Z Boom hydraulic Y ...
Страница 96: ...8 Technical specifications 96 ...
Страница 100: ...HARDI INTERNATIONAL A S Helgeshøj Allé 38 DK 2630 Taastrup DENMARK ...